{"product_id":"omron-cp1e-e30sdr-a-cp1e-series-cpu-unit-hardware","title":"Omron CP1E-E30SDR-A CP1E Series CPU Unit Hardware","description":"\u003cp\u003eConfigured for discrete logic execution and field device control in industrial control architectures, the \u003cstrong\u003eOmron CP1E-E30SDR-A\u003c\/strong\u003e (\u003cstrong\u003eCP1E-E30SDR-A\u003c\/strong\u003e CPU Unit Hardware) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e CP1E\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Type:\u003c\/strong\u003e E (Basic model)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Capacity:\u003c\/strong\u003e 30 (18 DC inputs, 12 relay outputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign Version:\u003c\/strong\u003e S (Renewal type)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Architecture:\u003c\/strong\u003e D (24 VDC inputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Configuration:\u003c\/strong\u003e R (Electromechanical relay outputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Source:\u003c\/strong\u003e A (100 to 240 VAC power supply)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP1E-E30SDR-A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.67 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e7.8 cm x 13.0 cm x 9.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e12.0 cm x 16.0 cm x 11.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 VA max. at 100 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 5 mA (Inputs 0.00 to 0.11: 7 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Switching Capacity\u003c\/td\u003e\n\u003ctd\u003e2 A at 250 VAC \/ 24 VDC (resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Capacity\u003c\/td\u003e\n\u003ctd\u003e2k steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Memory Capacity\u003c\/td\u003e\n\u003ctd\u003e2k words (DM Area)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Capability\u003c\/td\u003e\n\u003ctd\u003eNon-expandable (Basic E-type CPU structure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOmron PLC Processing Velocity \u0026amp; Signal Density\u003c\/h3\u003e\n\u003cp\u003eThe CP1E-E30SDR-A integrates an internal CPU execution core optimized for high-density discrete processing across 30 built-in I\/O channels. Backplane execution delays are eliminated through direct board-level trace routing between the CPU processor, the 18 DC input optocouplers, and the 12 electromechanical output relays. The instruction processing cycle operates with a basic instruction execution speed optimized for compact control operations. Firmware execution within the internal flash memory maintains deterministic scan cycles while managing peripheral USB communication and ladder program logic without external backplane expansion overhead.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CP1E-E30SDR-A CPU Unit\u003c\/li\u003e\n\u003cli\u003e1x Screw terminal block cover assembly\u003c\/li\u003e\n\u003cli\u003e1x Hardware installation instruction manual sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Securely latch the controller onto a standard 35 mm DIN rail (TH35-7.5\/TH35-15) using the rear-mounting slider lock. Provide a minimum vertical clearance of 50 mm above and below the unit for proper heat dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Power Supply Wiring:\u003c\/strong\u003e Connect 100 to 240 VAC mains to terminals L1 and L2\/N. Ensure protective earth (PE) is attached to the ground terminal using a wire gauge of at least 1.25 mm2 to suppress common-mode electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Isolation \u0026amp; Shielding:\u003c\/strong\u003e Route 24 VDC discrete sensor wiring separately from AC mains power cables by at least 100 mm. Ground all signal cable shields at a single point on the supply end to prevent ground loop currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Screw Tightening Torque:\u003c\/strong\u003e Torque all M3 terminal block screws to 0.5 N m. Ensure crimp terminals (M3 fork or round type) are properly insulated before applying voltage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping supported for internal components or wiring blocks on the CP1E-E30SDR-A?\u003c\/p\u003e\n\u003cp\u003eNo. The CP1E-E30SDR-A is a monolithic CPU unit without removable terminal blocks or hot-swappable modules. Main supply power must be isolated prior to servicing terminal connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum backplane expansion load limit for this CPU model?\u003c\/p\u003e\n\u003cp\u003eThe renewal basic E-type model (CP1E-E30SDR-A) does not support expansion I\/O units or option boards, resulting in a fixed total hardware capacity of 30 I\/O points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the hardware response latency for the 24 VDC digital inputs?\u003c\/p\u003e\n\u003cp\u003eThe default input ON\/OFF response delay is selectable via software settings from 0 ms to 32 ms, with a default hardware optocoupler latency of 8 ms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the CPU flash memory require a battery backup for ladder program preservation?\u003c\/p\u003e\n\u003cp\u003eNo. The program memory and system setup data are stored in non-volatile flash memory. A battery is only required if user DM data retaining or real-time clock functions are utilized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the insulation resistance and dielectric strength of the relay outputs?\u003c\/p\u003e\n\u003cp\u003eThe unit provides 2000 VAC at 50\/60 Hz for 1 minute between the AC power supply circuit and output contacts, with a minimum insulation resistance of 20 MOhm at 500 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the built-in USB port be used for field network master communications?\u003c\/p\u003e\n\u003cp\u003eNo. The integrated USB 2.0 type-B port functions exclusively as a peripheral programming and monitoring interface for CX-Programmer or CX-One software toolsets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat thermal derating applies when operating at the maximum ambient limit of 55 deg C?\u003c\/p\u003e\n\u003cp\u003eWhen operating at 55 deg C ambient temperature under continuous load, the simultaneous ON ratio of digital inputs and output relay loads must not exceed 80 percent of total channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the system functional ground be terminated to prevent EMI interference?\u003c\/p\u003e\n\u003cp\u003eConnect the functional ground terminal directly to a dedicated earth ground electrode with a resistance less than 100 Ohm, using 2.0 mm2 minimum wire gauge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306667393197,"sku":"CP1E-E30SDR-A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_cp1e-e30sdr-a_1.jpg?v=1788573202","url":"https:\/\/www.maxwellplc.com\/ga\/products\/omron-cp1e-e30sdr-a-cp1e-series-cpu-unit-hardware","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}