{"product_id":"omron-cj1w-id262-cj-series-dc-input-unit","title":"Omron CJ1W-ID262 CJ-series DC Input Unit","description":"\u003cp\u003eConfigured for 24 VDC discrete signal acquisition in CJ-series PLC systems, the \u003cstrong\u003eOmron CJ1W-ID262\u003c\/strong\u003e (\u003cstrong\u003eCJ1W-ID262\u003c\/strong\u003e DC Input Unit) provides 64 digital input channels through two 40-pin MIL connectors. The unit supports PNP\/NPN input devices, uses four 16-point common circuits, and allocates 4 words in the CJ I\/O system. Official Omron specifications define a 20.4 to 26.4 VDC permitted input range and 90 mA maximum internal current consumption.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-ID262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCJ-series DC Input Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eCJ Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O System\u003c\/td\u003e\n\u003ctd\u003eCJ I\/O Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eBasic I\/O Unit \/ Digital I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003ePNP\/NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eMIL connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Connectors\u003c\/td\u003e\n\u003ctd\u003e2 x 40-pin MIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Plug\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWords Allocated\u003c\/td\u003e\n\u003ctd\u003e4 words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Configuration\u003c\/td\u003e\n\u003ctd\u003e16 points\/common, 4 circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe official Omron product record identifies CJ1W-ID262 as a 64-input, 24 VDC digital input unit with two MIL connectors.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-ID262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDC Input Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA typical at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e5.6 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Voltage\u003c\/td\u003e\n\u003ctd\u003e19.0 VDC min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Current\u003c\/td\u003e\n\u003ctd\u003e3 mA min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Current\u003c\/td\u003e\n\u003ctd\u003e1 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Response Time\u003c\/td\u003e\n\u003ctd\u003e8.0 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Response Time\u003c\/td\u003e\n\u003ctd\u003e8.0 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Filter\u003c\/td\u003e\n\u003ctd\u003e0 to 32 ms configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Circuits\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Arrangement\u003c\/td\u003e\n\u003ctd\u003e16 points\/common, 4 circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSimultaneously ON Points\u003c\/td\u003e\n\u003ctd\u003e50% \/ 8 points per common at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 MOhm min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1,000 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Current Consumption\u003c\/td\u003e\n\u003ctd\u003e90 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.45 W at 5 VDC based on 90 mA maximum current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e9.0 cm x 3.1 cm x 8.36 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified in the provided data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e0.096 kg official unpacked value; 0.11 kg maximum catalog value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe physical dimensions are from Omron's product record: 90 mm height, 31 mm width, and 83.6 mm depth. The catalog also specifies 110 g maximum unit weight.\u003c\/p\u003e\n\u003ch3\u003ePLC Backplane and I\/O Density\u003c\/h3\u003e\n\u003cp\u003eCJ1W-ID262 is a high-density basic I\/O unit for the CJ I\/O Bus, providing 64 discrete input points in a 31 mm-wide module. The input circuits are arranged as four groups of 16 points with one common per group. At 24 VDC, Omron specifies a maximum simultaneous ON loading of 8 points per common, or 50%.\u003c\/p\u003e\n\u003cp\u003eThe unit accepts both PNP and NPN input devices, provided the same polarity is used for inputs sharing a common. Its configurable digital filter can be set from 0 to 32 ms to suppress unwanted external signal transitions.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CJ1W-ID262 DC Input Unit\u003c\/li\u003e\n\u003cli\u003e1x CJ-series 64-point input module\u003c\/li\u003e\n\u003cli\u003eMIL connector plugs are not included\u003c\/li\u003e\n\u003cli\u003eExternal connector wiring requires compatible 40-pin MIL connector hardware\u003c\/li\u003e\n\u003cli\u003eConnector-to-terminal conversion options are available separately, including Omron XW2K series conversion units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the CJ1W-ID262 in the CJ-series PLC rack according to the applicable CJ-series hardware installation manual.\u003c\/li\u003e\n\u003cli\u003eVerify that the PLC backplane and CPU configuration support the installed Basic I\/O Unit.\u003c\/li\u003e\n\u003cli\u003eApply a 24 VDC input supply within the specified 20.4 to 26.4 VDC operating range.\u003c\/li\u003e\n\u003cli\u003eKeep the input supply within the specified voltage range during normal and transient operating conditions.\u003c\/li\u003e\n\u003cli\u003eConnect the two 40-pin MIL interfaces using correctly keyed and rated connectors.\u003c\/li\u003e\n\u003cli\u003eMaintain the same signal polarity for inputs belonging to the same common circuit.\u003c\/li\u003e\n\u003cli\u003eDo not exceed 8 simultaneously ON input points per 16-point common group at 24 VDC.\u003c\/li\u003e\n\u003cli\u003eConfigure the digital input filter only as required by the signal characteristics; excessive filtering increases signal recognition delay.\u003c\/li\u003e\n\u003cli\u003eSeparate discrete input wiring from high-current switching and high-frequency power wiring where practical.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shield termination and grounding practices when the connected field devices or cable installation require noise control.\u003c\/li\u003e\n\u003cli\u003eConfirm the PLC I\/O allocation because the CJ1W-ID262 occupies 4 words in the CJ I\/O system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What input voltage does the CJ1W-ID262 require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The rated input voltage is 24 VDC, with a permitted input voltage range of 20.4 to 26.4 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many digital inputs are provided?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module provides 64 digital input channels arranged as four groups of 16 inputs, with one common circuit assigned to each group.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What connector does the CJ1W-ID262 use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It uses two 40-pin MIL connectors for field I\/O connections. Omron specifies that the connector plug is not included with the unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the physical dimensions of the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The official dimensions are 9.0 cm x 3.1 cm x 8.36 cm for height, width, and depth respectively.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum internal current consumption?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Omron specifies 90 mA maximum internal current consumption for the CJ1W-ID262. This value is used for PLC power-budget calculations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the input polarity be configured for PNP and NPN devices?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The module supports PNP\/NPN input devices. Inputs sharing a common must use the same polarity arrangement for that common circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What input response time is specified?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Both ON and OFF response times are specified at 8.0 ms maximum. The input filter can be configured between 0 and 32 ms through the applicable setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many inputs can be simultaneously ON?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e At 24 VDC, the specified simultaneous ON limit is 50%, corresponding to 8 ON points for each 16-point common circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306666311853,"sku":"CJ1W-ID262","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-ID262_1.jpg?v=1788156176","url":"https:\/\/www.maxwellplc.com\/ga\/products\/omron-cj1w-id262-cj-series-dc-input-unit","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}