NX-TS3201 Omron Temperature Input Unit Sysmac NX Series
-
Dimensions: 2.4 x 7.1 x 10.0 cm
-
Country of origin: Japan
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
The Omron NX-TS3201 serves as the primary NX-TS3201 Temperature Input Unit utilized to execute multi-channel RTD signal processing across Sysmac NX Series platforms. Equipped with 4 input points for three-wire Pt100 and Pt1000 sensors, it operates at a conversion time of 250 ms per unit. The module incorporates optical isolation between field circuits and the internal bus, transferring process data via Free-Run refreshing.
Part Number Code Breakdown
- NX: Sysmac modular slice I/O platform prefix.
- TS: Temperature input functional unit designation.
- 3: High-density 4-point input channel capacity index.
- 2: Resistance thermometer (RTD) circuit interface type.
- 01: Standard performance conversion rating (250 ms/unit conversion speed).
Technical Hardware Parameters
| Parameter | Specification |
|---|---|
| Model | NX-TS3201 |
| Brand | Omron |
| Origin | Japan |
| Weight | 0.14 kg |
| Shipping Dimensions | 2.4 x 7.1 x 10.0 cm |
| Operating Temp | 0 to 55 deg C |
| Power Consumption | 0.95 W max (NX bus power) |
| Capacity | 4 points |
| Temperature Sensor | Pt100 (three-wire), Pt1000 (three-wire) |
| Conversion Time | 250 ms/unit |
| Refreshing Method | Free-Run refreshing |
| Warm-Up Period | 10 minutes |
| Isolation Method | Power = Transformer, Signal = Photocoupler (Input to NX bus and channel-to-channel) |
| Insulation Resistance | 20 Mohm min between isolated circuits (at 100 VDC) |
| External Connection | Screwless clamping terminal block (16 terminals x 2) |
Deterministic Network Bus & Module Density
Designed for integration into Profinet / EtherNet/IP deterministic networks, the module communicates across the internal NX backplane bus using high-speed cyclic sampling. High backplane bus communication velocity allows all 4 RTD input values to be processed simultaneously without impacting controller cycle time. The platform maintains strict firmware flash compatibility across all Sysmac couplers, enabling optimal I/O density scaling in distributed automation systems.
Ordering Information & Package Scope
- 1 x Omron NX-TS3201 Temperature Input Unit
- 2 x Screwless Clamping Terminal Blocks (16 Terminals Each)
- 1 x Hardware Manual & Installation Guide
Mechanical Mounting & Field Wiring Rules
- DIN Rail Mounting: Align top housing slots with a 35 mm DIN rail and pivot the unit backward until the lower DIN clip locks firmly into place.
- RTD Sensor Connection: Connect three-wire Pt100 or Pt1000 sensors to the screwless clamping terminal block, ensuring equal lead wire resistance across all terminals.
- Warm-Up Phase: Allow a 10-minute warm-up period after power application to ensure internal measurement circuits stabilize before collecting process values.
- Backplane Mating: Slide adjacent NX modules together horizontally along the DIN rail until side bus connectors mesh securely.
- Noise Suppression: Route RTD wiring away from high-voltage motor power leads and terminate overall cable shields to the main panel functional ground.
Frequently Asked Questions
-
Is hot-swapping supported for the NX-TS3201 on an energized backplane?
No. You must disconnect main CPU backplane power and sensor excitation power prior to inserting or removing the unit.
-
Which RTD element types can be wired to the 4 input channels?
The module supports standard three-wire Pt100 and three-wire Pt1000 resistance temperature detectors across all 4 input points.
-
What is the required warm-up duration after initial power-up?
A warm-up period of at least 10 minutes is required for internal voltage references and A/D conversion circuits to reach thermal stability.
-
How does Free-Run refreshing execute temperature sampling?
Free-Run refreshing continuously executes analog-to-digital conversions independently of the controller's main task cycle time.
-
What isolation scheme is implemented between individual input channels?
Channel-to-channel isolation utilizes internal power transformers and signal photocouplers to prevent ground loops and inter-channel noise.
-
What terminal connection system is provided with the module?
Field signals terminate via two front-mounted screwless clamping terminal blocks containing 16 connection points each.
-
How does backplane communication velocity affect temperature updates?
High backplane velocity ensures that converted RTD data frames stream to the head coupler without network transmission lag.
-
How is firmware flash compatibility verified during module replacement?
Sysmac Studio validates hardware revision parameters against project configuration profiles before downloading firmware parameters.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.