{"product_id":"nx-ts2204-omron-resistance-thermometer-unit-sysmac-nx-series","title":"NX-TS2204 Omron Resistance Thermometer Unit Sysmac NX Series","description":"\u003cp\u003eConfigured for resistance temperature detector signal processing in Sysmac NX Series environments, the \u003cstrong\u003eOmron NX-TS2204\u003c\/strong\u003e (\u003cstrong\u003eNX-TS2204\u003c\/strong\u003e Temperature Input Unit) provides direct physical\/electrical execution. It features 2 input points for three-wire Pt100 and Pt1000 RTD sensors, operating with a conversion time of 60 ms per unit and achieving 0.001 deg C resolution. The unit utilizes Free-Run refreshing across internal bus structures to stream digitized temperature metrics into controller memory.\u003c\/p\u003e\n\u003ch3\u003ePart Number Nomenclature \u0026amp; Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Sysmac modular slice I\/O series hardware platform designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTS\u003c\/strong\u003e: Temperature input function module classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2\u003c\/strong\u003e: 2-channel input point capacity index.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2\u003c\/strong\u003e: Resistance thermometer (RTD) input circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e04\u003c\/strong\u003e: Fine-resolution specification (0.001 deg C max, 60 ms\/unit conversion speed).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Summary\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-TS2204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.07 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.2 x 7.1 x 10.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.90 W max (CPU \/ Comm Unit connection) \/ 0.75 W max (Coupler connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e2 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Compatibility\u003c\/td\u003e\n\u003ctd\u003ePt100 (three-wire), Pt1000 (three-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 deg C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e60 ms\/unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Detection Current\u003c\/td\u003e\n\u003ctd\u003eApprox 0.25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Resistance Effect\u003c\/td\u003e\n\u003ctd\u003e0.06 deg C\/ohm max (20 ohm max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarm-Up Period\u003c\/td\u003e\n\u003ctd\u003e30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Scheme\u003c\/td\u003e\n\u003ctd\u003eTransformer (Power) \/ Digital Isolator (Signal) between inputs and NX bus \/ between channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 Mohm min between isolated circuits (at 100 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e510 VAC between isolated circuits for 1 minute (5 mA max leakage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefreshing Method\u003c\/td\u003e\n\u003ctd\u003eFree-Run refreshing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrewless clamping terminal block (16 terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Communications \u0026amp; Architecture\u003c\/h3\u003e\n\u003cp\u003eCommunicating via Profinet \/ EtherNet\/IP deterministic networks, the module transmits process variable data across internal backplane buses. High backplane bus communication velocity prevents data transfer bottlenecks during cyclic update routines. The slice design guarantees full firmware flash compatibility across Sysmac CPU and coupler heads, streamlining I\/O density scaling inside control panel assemblies.\u003c\/p\u003e\n\u003ch3\u003eShipping Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-TS2204 Temperature Input Module\u003c\/li\u003e\n\u003cli\u003e1 x Screwless Clamping Terminal Block Assembly (16 Terminals)\u003c\/li\u003e\n\u003cli\u003e1 x Installation Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePanel Installation \u0026amp; Field Wiring Rules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Attachment\u003c\/strong\u003e: Mount the top rail notch onto standard 35 mm DIN rail profiles and pivot downward until the lower lock secures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Wire Termination\u003c\/strong\u003e: Wire three-wire Pt100 or Pt1000 sensors into the screwless terminal block, maintaining equal conductor resistance on all leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Stabilization\u003c\/strong\u003e: Allow a 30-minute warm-up period after power application to stabilize internal measuring circuits before taking measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Integration\u003c\/strong\u003e: Align lateral guides with adjacent NX modules and press horizontally until internal bus interfaces click together.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Shielding\u003c\/strong\u003e: Connect cable shields directly to the panel functional ground bar using short lead lengths to reduce noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan the NX-TS2204 module be hot-swapped while backplane power is active?\u003c\/p\u003e\n\u003cp\u003eNo. All power supplies to the CPU unit, coupler, and field circuits must be disconnected before installing or removing the unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich RTD sensors are compatible with the input channels?\u003c\/p\u003e\n\u003cp\u003eThe unit supports three-wire Pt100 and three-wire Pt1000 resistance temperature detectors across both input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow long must the module warm up after initial power-on?\u003c\/p\u003e\n\u003cp\u003eA warm-up duration of 30 minutes is required for internal reference voltage circuits to reach operational thermal equilibrium.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the detection current applied to connected RTD sensors?\u003c\/p\u003e\n\u003cp\u003eThe module applies a low constant sensing current of approximately 0.25 mA to minimize self-heating effects on RTD elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does Free-Run refreshing affect data updates to the controller?\u003c\/p\u003e\n\u003cp\u003eFree-Run refreshing executes A\/D conversions asynchronously from the CPU task cycle, updating internal output registers continuously.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat isolation technique is used between individual channels?\u003c\/p\u003e\n\u003cp\u003eChannel-to-channel isolation relies on power transformers and digital signal isolators to maintain electrical separation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum allowable conductor resistance for RTD wiring?\u003c\/p\u003e\n\u003cp\u003eLead wire resistance must not exceed 20 ohms per conductor, with a maximum resistance effect of 0.06 deg C per ohm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is firmware flash compatibility ensured when replacing modules?\u003c\/p\u003e\n\u003cp\u003eSysmac Studio checks hardware revision parameters against project files during download to ensure full system firmware compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306669785261,"sku":"NX-TS2204","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NX-TS2204.jpg?v=1790221391","url":"https:\/\/www.maxwellplc.com\/ga\/products\/nx-ts2204-omron-resistance-thermometer-unit-sysmac-nx-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}