{"product_id":"nx-pg0122-omron-pulse-output-unit-nx-series","title":"NX-PG0122 Omron Pulse Output Unit NX-series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX-PG0122\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX-PG0122\u003c\/strong\u003e Pulse Output Unit, operates as a dedicated hardware component for open collector pulse string execution and open-loop motion control within Omron automation network platforms.\u003c\/p\u003e\n\u003ch3\u003eDesignation Matrix \u0026amp; Model Suffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe product nomenclature defines structural control channel allocations, output configurations, and backplane communication capabilities within the modular hardware environment.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Modular control system series optimized for high-speed backplane bus communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePG\u003c\/strong\u003e: Dedicated pulse output module classification designed for stepper and servo drive interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0122\u003c\/strong\u003e: Single-channel PNP type open collector output configuration supporting synchronous I\/O refreshing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-PG0122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.07 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e12 cm x 10 cm x 7.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e20 mA max. (from I\/O power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pulse Output Speed\u003c\/td\u003e\n\u003ctd\u003e500 kpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Form\u003c\/td\u003e\n\u003ctd\u003ePNP open collector output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition Control Range\u003c\/td\u003e\n\u003ctd\u003e-2,147,483,648 to 2,147,483,647 pulses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Control Range\u003c\/td\u003e\n\u003ctd\u003e1 to 500,000 pps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication Velocity \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module integrates seamlessly into the backplane bus communication velocity architecture, maintaining deterministic data exchanges with connected CPU masters. Firmware flash compatibility ensures seamless system updates without interrupting position registers, while I\/O density scaling allows efficient system expansion across multiple modular nodes without sacrificing pulse train timing precision or command synchronization.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-PG0122 Pulse Output Unit\u003c\/li\u003e\n\u003cli\u003e1 x 16-terminal screwless clamping terminal block\u003c\/li\u003e\n\u003cli\u003e1 x Safety and hardware installation manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnclosure Mounting \u0026amp; Field Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN Rail Installation\n\u003cul\u003e\n\u003cli\u003eMount the module securely onto a standard 35 mm DIN rail within a protective control panel enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSignal Cable Routing\n\u003cul\u003e\n\u003cli\u003eKeep pulse output cable lengths within 3 m max to prevent signal degradation and electromagnetic distortion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTerminal Connection\n\u003cul\u003e\n\u003cli\u003eInsert stripped conductor wires directly into the 16-terminal screwless clamping block without utilizing screw-tightening tools.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eGrounding Execution\n\u003cul\u003e\n\u003cli\u003eConnect the module grounding path to the main enclosure earth bar to suppress high-frequency noise interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Operation Frequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of pulse output configuration does the NX-PG0122 utilize?\u003c\/p\u003e\n\u003cp\u003eThe unit provides an open collector output form utilizing PNP type switching for pulse string delivery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum achievable pulse output speed?\u003c\/p\u003e\n\u003cp\u003eThe hardware delivers a maximum pulse output frequency of up to 500 kpps for connected motor drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many channels are supported on this module?\u003c\/p\u003e\n\u003cp\u003eThe module provides a single dedicated control channel for pulse output and external signal management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat control method is implemented for motion execution?\u003c\/p\u003e\n\u003cp\u003eIt uses open-loop control through high-speed pulse string output directed to stepper or servo drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the allowable position control pulse count range?\u003c\/p\u003e\n\u003cp\u003ePosition targets span from -2,147,483,648 to 2,147,483,647 pulses across internal registers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is power supplied to the module input\/output circuits?\u003c\/p\u003e\n\u003cp\u003eCurrent consumption from the external I\/O power supply is limited to 20 mA maximum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat external terminal block type comes with the unit?\u003c\/p\u003e\n\u003cp\u003eIt features a screwless clamping terminal block comprising 16 terminal points for secure wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum recommended cable length for pulse lines?\u003c\/p\u003e\n\u003cp\u003eField wiring cables connected to the pulse outputs must not exceed 3 m in length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306637901997,"sku":"NX-PG0122","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-pg0122_1.jpg?v=1791554457","url":"https:\/\/www.maxwellplc.com\/ga\/products\/nx-pg0122-omron-pulse-output-unit-nx-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}