{"product_id":"nx-pg0112-omron-nx-series-pulse-output-unit","title":"NX-PG0112 Omron NX Series Pulse Output Unit","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX-PG0112\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX-PG0112\u003c\/strong\u003e Pulse Output Unit, operates as a dedicated hardware component for pulse train motion control execution within EtherCAT and NX bus systems.\u003c\/p\u003e\n\u003ch3\u003eModel Identification \u0026amp; Function Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePG0: Pulse output unit hardware classification\u003c\/li\u003e\n\u003cli\u003e1: 1-channel motion control architecture\u003c\/li\u003e\n\u003cli\u003e1: Open collector NPN transistor circuit specification\u003c\/li\u003e\n\u003cli\u003e2: Synchronous I\/O refreshing support function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Hardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-PG0112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.07 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e12 mm x 100 mm x 71 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eCurrent consumption from I\/O power supply: 20 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Output Method\u003c\/td\u003e\n\u003ctd\u003eOpen collector (NPN type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pulse Output Speed\u003c\/td\u003e\n\u003ctd\u003e500 kpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Control Range\u003c\/td\u003e\n\u003ctd\u003e1 to 500,000 pps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition Control Range\u003c\/td\u003e\n\u003ctd\u003e-2,147,483,648 to 2,147,483,647 pulses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection Type\u003c\/td\u003e\n\u003ctd\u003eScrewless clamping terminal block (16 terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Bus Architecture\u003c\/h3\u003e\n\u003cp\u003eThe unit executes synchronous I\/O refreshing over the high-speed NX bus architecture, maintaining tight cycle time alignment with the primary motion controller. Firmware flash compatibility across system revisions enables low-jitter pulse train generation without disrupting background backplane communication velocity. High-density I\/O density scaling allows precise positioning pulses to be emitted to external servo or stepper drives simultaneously across distributed rack topologies.\u003c\/p\u003e\n\u003ch3\u003eShipping Package Content\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x NX-PG0112 Pulse Output Unit Assembly\u003c\/li\u003e\n\u003cli\u003e1 x 16-Pin Screwless Clamping Terminal Block\u003c\/li\u003e\n\u003cli\u003e1 x Terminal Block Mounting Guide Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Deployment \u0026amp; Wiring Recommendations\u003c\/h3\u003e\n\u003ch4\u003eMechanical Assembly\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSnap the module firmly onto a standard 35 mm DIN rail until the locking tab engages fully.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum 30 mm vertical clearance above and below the housing for natural convective cooling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWiring Directives\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInsert field leads into the screwless push-in terminals using conductors stripped to the recommended length.\u003c\/li\u003e\n\u003cli\u003eLimit pulse output signal cable runs to a maximum distance of 3 m using shielded twisted-pair cabling to minimize signal distortion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Inquiry Resolutions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat pulse output modes are selectable on the module?\u003c\/p\u003e\n\u003cp\u003eThe unit supports forward\/reverse pulse direction outputs or pulse plus direction output modes configured via controller software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat drive types can be controlled by this unit?\u003c\/p\u003e\n\u003cp\u003eIt directly drives servo amplifiers or stepper motor controllers equipped with open-collector pulse string input interfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is I\/O refreshing synchronized across the backplane?\u003c\/p\u003e\n\u003cp\u003eThe hardware operates using synchronous I\/O refreshing or task period prioritized refreshing aligned with the controller cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum output pulse rate supported?\u003c\/p\u003e\n\u003cp\u003eThe open collector NPN transistor output stage generates high-speed pulse strings up to a maximum of 500 kpps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many physical I\/O terminals are available on the connector?\u003c\/p\u003e\n\u003cp\u003eThe detachable screwless terminal block provides 16 individual connection points for field signal interface wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the current drain from the I\/O power supply?\u003c\/p\u003e\n\u003cp\u003eThe internal electronics draw a maximum current of 20 mA from the connected field I\/O power supply line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre external inputs available on the module assembly?\u003c\/p\u003e\n\u003cp\u003eThe unit incorporates 2 dedicated digital external inputs alongside 3 transistor pulse output circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module support hot-swapping under active backplane power?\u003c\/p\u003e\n\u003cp\u003ePower to the NX bus backplane must be isolated before detaching or inserting the module to avoid circuit damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306676109485,"sku":"NX-PG0112","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NX-PG0112_3.jpg?v=1790216750","url":"https:\/\/www.maxwellplc.com\/ga\/products\/nx-pg0112-omron-nx-series-pulse-output-unit","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}