{"product_id":"nx-pa9001-omron-power-supply-unit-nx-series","title":"NX-PA9001 Omron Power Supply Unit NX Series","description":"\u003cp data-path-to-node=\"4\"\u003eThe \u003cb data-path-to-node=\"4\" data-index-in-node=\"4\"\u003eOmron NX-PA9001\u003c\/b\u003e, also cataloged as the \u003cb data-path-to-node=\"4\" data-index-in-node=\"43\"\u003eNX-PA9001\u003c\/b\u003e Power Supply Unit, operates as a dedicated hardware component for primary AC power conversion and system bus power delivery within NX-Series control racks.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003ePower Conversion Architecture \u0026amp; Operational Limits\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eThe hardware accepts a wide-range input voltage spanning 100 to 240 VAC (85 to 264 VAC absolute limits) at 50\/60 Hz (47 to 63 Hz). Total output power delivery capability reaches 90 W max., maintaining high system conversion efficiency under full operational load. Cold-start inrush current is limited to 20 A at 100 VAC and 40 A at 200 VAC within an 8 ms pulse window at ambient temperature. An integrated SPST-NO RUN contact provides discrete system status signaling rated up to 250 VAC, 2 A for resistive loads.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eTechnical Performance Matrix\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003eNX-PA9001\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e0.57 Kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e3 Kg (Gross Boxed Weight)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003e0 deg C to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003e150 VA max.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003e100 to 240 VAC (85 to 264 VAC range), 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003eOutput Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003e90 W max. total\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,0,0\"\u003eRUN Output Relay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,1,0\"\u003eSPST-NO (250 VAC\/24 VDC 2 A resistive, 120 VAC 0.5 A inductive)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,0,0\"\u003eIsolation \u0026amp; Dielectric\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,1,0\"\u003e20 Mohm min. at 500 VDC; 2,300 VAC for 1 min (Leakage 5 mA max.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eBackplane Power Distribution \u0026amp; Control Network Stability\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe supply unit provides regulated power directly across the backplane bus, enabling predictable backplane bus communication velocity and sustained network processing across connected CPU modules and expansion drops. High dielectric isolation (2,300 VAC for 1 minute between AC external and GR terminals) shields sensitivity in EtherNet\/IP and EtherCAT deterministic networks from transient line surges, suppressing noise coupling across dense local I\/O configurations.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003ePackage Component List\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e1 x Omron NX-PA9001 Power Supply Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e1 x AC Input Terminal Connector Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e1 x Grounding Clip Terminal Block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e1 x Hardware Instruction Manual Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eField Cabinet Installation \u0026amp; Grounding Rules\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003eMount the module firmly on a standard 35 mm DIN rail in an upright vertical orientation to optimize natural heat dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003eMaintain a clearance of at least 50 mm above and below the power module casing to facilitate unhindered airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003eConnect a dedicated protective earth conductor to the GR terminal using a low-impedance wire bond to meet noise immunity standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003eEnsure AC input wiring is routed in a separate wire channel away from sensitive DC signal lines and fieldbus communications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eQ: What is the permitted input voltage range for main power input?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,0,1\"\u003eA: The unit accepts a rated supply of 100 to 240 VAC, operating across an extended absolute limit of 85 to 264 VAC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eQ: What total power output capacity does the unit supply to the system?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,1,1\"\u003eA: The module supplies up to 90 W total maximum power capacity to the internal bus and connected racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eQ: What are the electrical ratings of the integrated RUN status contact?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,2,1\"\u003eA: The SPST-NO contact supports switching up to 250 VAC at 2 A resistive load and 120 VAC at 0.5 A inductive load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003eQ: How much peak inrush current occurs during a cold start at 200 VAC?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,3,1\"\u003eA: The inrush current reaches a maximum of 40 A for a duration of 8 ms during room temperature cold startup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003eQ: What dielectric isolation strength is specified across external AC and GR terminals?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,4,1\"\u003eA: It withstands 2,300 VAC at 50\/60 Hz for 1 minute with a leakage current limited to 5 mA maximum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003eQ: Is a separate service power output terminal provided on the front panel?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,5,1\"\u003eA: No, an external auxiliary service power output terminal is not provided on this hardware configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003eQ: What insulation resistance level is measured between AC external and GR terminals?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,6,1\"\u003eA: The insulation resistance measures 20 Mohm minimum when tested at 500 VDC between terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003eQ: What is the gross shipping weight for transport calculations?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,7,1\"\u003eA: The individual net weight is 0.57 Kg, while the complete protective shipping package weighs 3 Kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306624467117,"sku":"NX-PA9001","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-pa9001.jpg?v=1791647534","url":"https:\/\/www.maxwellplc.com\/ga\/products\/nx-pa9001-omron-power-supply-unit-nx-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}