{"product_id":"nx-id6142-6-omron-nx-series-digital-input-unit","title":"NX-ID6142-6 Omron NX Series Digital Input Unit","description":"\u003cp data-path-to-node=\"4\"\u003eThe \u003cb data-path-to-node=\"4\" data-index-in-node=\"4\"\u003eOmron NX-ID6142-6\u003c\/b\u003e, also cataloged as the \u003cb data-path-to-node=\"4\" data-index-in-node=\"45\"\u003eNX-ID6142\u003c\/b\u003e Digital Input Module, operates as a dedicated hardware component for 24 VDC discrete signal conditioning within Sysmac NX automation networks. It provides 32 high-density digital input channels compatible with NPN or PNP field circuit topologies. Interfacing via a multi-pin Fujitsu connector, the unit utilizes Free-Run or Synchronous I\/O refreshing methods to align input signal sampling directly with master processing cycles across the local backplane.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eHardware Nomenclature \u0026amp; Part Breakdown\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eNX\u003c\/b\u003e: Modular Sysmac I\/O series hardware platform designation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eID\u003c\/b\u003e: Discrete DC digital input module functional class.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003e6\u003c\/b\u003e: High-density 32-channel input capacity allocation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003e1\u003c\/b\u003e: Bi-directional input circuit supporting both NPN and PNP sensor connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003e42\u003c\/b\u003e: Standard 24 VDC operating voltage rating with fast signal response characteristics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003e-6\u003c\/b\u003e: Front panel high-density Fujitsu connector interface type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eTechnical Parameters \u0026amp; Operating Limits\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003eNX-ID6142-6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e0.09 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e3.0 x 7.1 x 10.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003e0.90 W max (NX bus power) \/ 0.96 W max (I\/O power)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003eInput Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003e32 points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003eNominal Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,0,0\"\u003eCircuit Topology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,1,0\"\u003eNPN \/ PNP bi-directional\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,0,0\"\u003eResponse Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,1,0\"\u003eExceeds 1 us (ON\/OFF)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,0,0\"\u003eRefreshing Architecture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,1,0\"\u003eFree-Run refreshing or Switching Synchronous I\/O refreshing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,13,0,0\"\u003eTermination Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,13,1,0\"\u003eFujitsu Connector (-6 specification)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eDeterministic Networking \u0026amp; Module Density\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eHigh I\/O density scaling allows 32 distinct input signals to be processed within a single compact slice width, optimizing cabinet space in complex control systems. Operating over Profinet \/ EtherNet\/IP deterministic networks, the module transmits real-time channel state data directly to the head coupler. Internal ASIC processing maintains rapid backplane bus communication velocity while ensuring cross-platform firmware flash compatibility across all Sysmac control systems.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eScope of Delivery\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e1 x Omron NX-ID6142-6 Digital Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e1 x Protective Dust Cover Cap for Fujitsu Connector Interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003ePanel Assembly \u0026amp; Field Cabling Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eDIN Rail Mounting\u003c\/b\u003e: Engage top rail hooks onto a standard 35 mm DIN rail and push the module housing backward until the bottom latch snaps locked.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eFujitsu Connector Termination\u003c\/b\u003e: Attach prefabricated, double-shielded harness assemblies to the front-facing Fujitsu connector plug.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eInter-Module Assembly\u003c\/b\u003e: Align lateral mounting guide tracks with the adjoining NX slice and slide firmly sideways to lock backplane contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eNoise Suppression \u0026amp; Shielding\u003c\/b\u003e: Connect cable braided shields directly to the panel functional ground bus bar using short grounding straps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,4,0\"\u003e\u003cb data-path-to-node=\"14,4,0\" data-index-in-node=\"0\"\u003eSupply Voltage Verification\u003c\/b\u003e: Measure and confirm that external field power supplies output 24 VDC prior to energizing input signal loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eIs live hot-swapping supported for the NX-ID6142-6 on an energized backplane?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,0,1\"\u003eNo. You must turn off main controller power and external field power supplies before inserting or removing the module from the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eHow are NPN and PNP sensor outputs wired to the unit?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,1,1\"\u003eThe bi-directional optocoupler inputs support both NPN (sinking) and PNP (sourcing) sensor configurations depending on common wiring terminal polarity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eWhat advantage does Synchronous I\/O refreshing provide during runtime?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,2,1\"\u003eSynchronous I\/O refreshing locks input sampling precisely to the primary task cycle of the controller for deterministic data processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003eWhat protection is supplied for the unpopulated Fujitsu connector pins?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,3,1\"\u003eA removable plastic protective dust cover cap is installed over the connector pins during factory shipping to prevent contamination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003eDoes the input hardware support high-frequency pulse detection?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,4,1\"\u003eYes. The internal hardware filtering circuit yields ON\/OFF signal transition response speeds that comfortably exceed 1 us.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003eHow does the internal bus maintain communication speed with 32 active channels?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,5,1\"\u003eAn internal processing ASIC packs all 32 channel digital states into a single unified bus data frame per refresh transmission cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003eCan firmware flash compatibility be validated prior to online deployment?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,6,1\"\u003eYes. Software tools such as Sysmac Studio verify hardware revision codes against project profile files prior to code download.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003eIs external field power required to drive the module input circuits?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,7,1\"\u003eYes. An external 24 VDC power supply must be connected to power the field-side optical isolation loops and sensor circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306668867757,"sku":"NX-ID6142-6","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NX-ID6142-6_2.jpg?v=1790221706","url":"https:\/\/www.maxwellplc.com\/ga\/products\/nx-id6142-6-omron-nx-series-digital-input-unit","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}