{"product_id":"nx-da2605-omron-analog-i-o-unit-nx-series","title":"NX-DA2605 Omron Analog I\/O Unit NX- Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX-DA2605\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX-DA2605\u003c\/strong\u003e Analog I\/O unit, operates as a dedicated hardware component for high-resolution voltage signal output processing within EtherCAT and NX-bus I\/O system architectures.\u003c\/p\u003e\n\u003ch3\u003eFunctional Matrix \u0026amp; Architecture\u003c\/h3\u003e\n\u003cp\u003eThe NX-DA2605 is structured as a dedicated analog output expansion module within the Omron NX series platform. The base hardware model provides multi-channel digital-to-analog signal conversion without requiring additional sub-component option boards. Internal circuitry translates internal system bus digital values directly into stable differential voltage outputs across the -10 to +10 V range.\u003c\/p\u003e\n\u003ch3\u003eSystem Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-DA2605\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output Range\u003c\/td\u003e\n\u003ctd\u003e-10 to +10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Method\u003c\/td\u003e\n\u003ctd\u003eDifferential Input\/Output Circuitry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 MOhm min. between isolated circuits (at 100 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e7.1 x 1.2 x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.07 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Bus Communication\u003c\/td\u003e\n\u003ctd\u003eEtherCAT \/ NX-bus deterministic synchronous bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus \u0026amp; High-Density Scalability\u003c\/h3\u003e\n\u003cp\u003eThe NX-DA2605 interface utilizes high-speed backplane bus communication velocity to deliver deterministic response synchronization across scalable PLC platforms. High-density I\/O configuration allows tight physical packing on standard DIN-rail topologies without degradation of throughput. Internal firmware flash compatibility ensures synchronized operational execution alongside CPU units over EtherCAT networks, eliminating loop latencies in closed-loop voltage control operations.\u003c\/p\u003e\n\u003ch3\u003eScope of Delivery\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-DA2605 Analog I\/O Unit\u003c\/li\u003e\n\u003cli\u003eIntegrated Push-In Plus terminal block assembly\u003c\/li\u003e\n\u003cli\u003eFactory test documentation and installation sheet\u003c\/li\u003e\n\u003cli\u003eAnti-static protective enclosure packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Assembly \u0026amp; Wiring Practice\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Assembly\u003c\/strong\u003e: Secure the module onto 35 mm DIN rail profiles using the integrated locking mechanism. Ensure solid mechanical connection to avoid physical stress on internal bus contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding\u003c\/strong\u003e: Route differential analog voltage lines using twisted-pair shielded cables. Earth the cable shield at a single termination point to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Distance\u003c\/strong\u003e: Maintain separation between low-voltage signal cabling and heavy AC power lines to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDispatch \u0026amp; Freight Logistics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShipping timeline: 2-7 days when payment finish\u003c\/li\u003e\n\u003cli\u003eCarrier service: Express transport via DHL, FEDEX, or UPS\u003c\/li\u003e\n\u003cli\u003eEnclosure standard: ESD anti-static industrial packaging with high-density shock-absorption padding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Technical Inquiries\u003c\/h3\u003e\n\u003cp\u003eQ: What is the isolation capability between distinct operational circuits on the NX-DA2605?\u003c\/p\u003e\n\u003cp\u003eA: The internal hardware maintains an insulation resistance of at least 20 MOhm at 100 VDC between isolated circuit paths to prevent stray potential damage.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support single-ended or differential output signal loops?\u003c\/p\u003e\n\u003cp\u003eA: The unit architecture utilizes differential output routing designed for industrial voltage ranges spanning -10 to +10 V.\u003c\/p\u003e\n\u003cp\u003eQ: How does the unit exchange operational data with the primary PLC controller?\u003c\/p\u003e\n\u003cp\u003eA: Data exchange is executed deterministically over the proprietary NX-bus backplane interface linked to the main CPU or EtherCAT coupler unit.\u003c\/p\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306649764013,"sku":"NX-DA2605","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-da2605_1.jpg?v=1790660895","url":"https:\/\/www.maxwellplc.com\/ga\/products\/nx-da2605-omron-analog-i-o-unit-nx-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}