Configured for high-density analog signal acquisition in Sysmac I/O networks, the OMRON NX-AD4603 (NX-AD4603 Analog Input Module) provides direct physical/electrical execution. It digitizes up to 8 single-ended voltage input channels across a -10 to +10 V range with 1/8000 full-scale resolution. The module converts analog inputs into a decimal range of -4000 to 4000 via Free-Run refreshing, maintaining an overall accuracy of 0.2% at 25 deg C across the NX I/O backplane.
Model Number Code Structure
- NX: Sysmac modular slice I/O hardware platform specification.
- AD: Analog input processing module classification.
- 4603: 8-channel voltage input configuration (-10 to +10 V, 1/8000 resolution).
Technical Performance Metrics
| Parameter | Specification |
|---|---|
| Model | NX-AD4603 |
| Brand | OMRON |
| Origin | Japan |
| Weight | 0.070 kg |
| Shipping Dimensions | 15 x 10 x 5 cm |
| Operating Temp | 0 to 55 deg C |
| Power Consumption | Not specified |
| Number of Inputs | 8 single-ended points |
| Input Range | -10 to +10 V |
| Resolution | 1/8000 (full scale) |
| Conversion Value | -4000 to 4000 (0 to 100%) |
| Conversion Range | -5 to 105% (full scale) |
| Overall Accuracy | 0.2% full scale (at 25 deg C) |
| Refreshing Method | Free-Run refreshing |
| Absolute Maximum Rating | +/-15 V |
Backplane Integration & High-Density Acquisition
The module transmits digitized channel data to the main CPU through high backplane bus communication velocity across the internal NX I/O bus. Integrating these inputs within Profinet / EtherNet/IP deterministic networks ensures cyclic sampling without signal latency. High I/O density scaling allows 8 voltage channels in a compact slice, maintaining firmware flash compatibility across network couplers and controller backplanes.
Commercial Package Contents
- 1 x OMRON NX-AD4603 Analog Input Module
- 1 x Push-In Plus Terminal Block
- 1 x Hardware Installation Sheet
Panel Installation & Field Cabling Directives
- DIN Rail Mounting: Align the top module guide with the DIN rail and press firmly until the lower locking lever snaps into place.
- Terminal Block Cable Prep: Strip solid or ferruled wiring to specified length and insert directly into Push-In Plus terminal slots.
- Signal Shielding: Use shielded twisted-pair cables for -10 to +10 V input runs and ground shields to the functional ground bar.
- Overvoltage Prevention: Ensure signal levels remain strictly within the +/-15 V absolute maximum limit to prevent front-end burnout.
- Adjacent Unit Installation: Lock side connectors securely against adjoining NX I/O units to maintain backplane bus continuity.
Technical FAQ
-
Does the NX-AD4603 support live hot-swapping on an active NX I/O rack?
No. Main power to the CPU unit and NX I/O expansion bus must be isolated before removing or inserting the module.
-
How does the Free-Run refreshing method execute signal conversions?
Analog-to-digital conversion operates continuously in asynchronous cycles, independent of the CPU primary task execution cycle.
-
What happens if an input channel experiences a voltage exceeding +/-15 V?
Exceeding the +/-15 V absolute maximum rating causes hardware degradation or permanent burnout of internal input circuitry.
-
How are single-ended inputs wired to minimize common-mode noise?
Connect common return lines to shared terminal reference points and use shielded wiring terminated at a single panel ground.
-
What indicates an over-range condition on the converted digital output value?
Input values between -5% and 105% convert linearly beyond -4000 to 4000, clipping at maximum conversion range boundaries.
-
Is calibration required for individual channels prior to operational deployment?
Factory calibration delivers 0.2% full-scale overall accuracy at 25 deg C without requiring manual zero/span adjustments.
-
How is firmware flash compatibility maintained across different coupler units?
The controller checks module device revision codes against system configuration profiles during backplane startup checks.
-
What gauge wire is recommended for the Push-In Plus terminal connectors?
Use 0.25 to 1.5 mm2 (AWG 24 to 16) solid wires or stranded wires with insulated ferrules for reliable connection.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.