The Omron NS5-TQ10B-V2, also cataloged as the NS5-TQ10 Programmable Terminal, operates as a dedicated hardware component for graphical process monitoring and serial register interaction within industrial PLC field bus networks.
Model Architecture & Variant Decoding
- NS5: Represents the 5.7-inch display frame class within the human-machine interface product lineup.
- TQ: Designates TFT color active-matrix LCD panel hardware architecture.
- 10: Specifies 320 x 240 pixel resolution (QVGA layout standard).
- B: Denotes black enclosure housing finish.
- V2: Identifies System Version 2 hardware iteration with expanded internal function memory.
Technical Data Specifications
| Parameter | Specification |
|---|---|
| Model | NS5-TQ10B-V2 |
| Brand | Omron |
| Origin | Japan |
| Weight | 1.0 kg |
| Shipping Dimensions | 195 mm x 142 mm x 54 mm |
| Operating Temp | 0 to 50 deg C |
| Display Type | TFT Color LCD |
| Screen Size | 5.7 inch |
| Resolution | 320 x 240 dots |
| Case Color | Black |
| Ethernet Interface | Not supported |
| Power Consumption | 15 W max. |
Fieldbus Communications and Firmware Protocol
Data synchronization across controller networks utilizes direct memory link protocols via host serial interfaces. Internal communication controllers manage high-rate register mapping to prevent network latency during multi-screen tag updates. System execution stability relies on firmware flash compatibility, preventing boot integrity degradation following unexpected panel power interruptions. Integrated backplane communication drivers ensure deterministic screen switching and steady coordinate processing during continuous high-density I/O register polling cycles.
Package Contents
- 1 x Omron NS5-TQ10B-V2 Programmable Terminal
- 1 x 24 VDC Power Supply Terminal Block
- 4 x Panel Mounting Brackets
- 1 x Rear Sealing Rubber Gasket
Field Mounting and Wiring Standards
Panel Cutout and Clearance
Cut a rectangular mounting hole in the enclosure door according to standard panel dimensions. Maintain a minimum clearance of 100 mm around all enclosure sides to ensure free airflow convection through rear heat dissipation vents.
Mechanical Securing Procedure
Check that the perimeter sealing ring is properly positioned inside the bezel slot. Insert the terminal into the door cutout and tighten the four mounting screws diagonally to achieve uniform pressure for IP65 front ingress protection.
DC Power Grounding
Wire a regulated 24 VDC supply to the input terminal connector using stranded 16 AWG wire. Route a short, low-impedance grounding wire from the terminal Functional Ground (FG) lug directly to the cabinet ground bar to mitigate electromagnetic interference.
Technical FAQ
-
Does the panel support hot-swapping while connected to an active controller?
Serial communication cables can be attached or detached during operation, but disconnecting main 24 VDC power while active halts processing and can corrupt unwritten SRAM data logs.
-
How does lack of Ethernet support affect system communications?
Without onboard Ethernet, host communication relies exclusively on RS-232C or RS-422A/485 serial interfaces, requiring direct point-to-point or multidrop cable topologies.
-
What causes screen artifacts or unresponsiveness during touch operations?
Electrical noise on the 24 VDC line or inadequate FG earthing disrupts capacitive/resistive touch calibration. Ensure clean power routing and bonded enclosure ground connections.
-
What precautions must be taken during firmware updates?
Maintain an uninterrupted 24 VDC power source throughout the flash write process. Power loss during flash writes damages core boot sectors and requires factory servicing.
-
How should cables be routed to prevent serial signal degradation?
Route communication cables in dedicated grounded conduits away from motor drives and high-voltage AC lines to prevent noise induction and signal loss.
-
What mounting orientation is required for thermal management?
Install the unit vertically (within 30 deg of perpendicular) to maintain optimal heat convection through the top and bottom rear ventilation slots.
-
How are communication timeout errors handled during high network loads?
Timeouts generate visual fault flags on the screen. Communication retry intervals and timeout durations can be adjusted inside the system setup menu.
-
What type of line protection is recommended for the DC power feed?
Install a fast-acting 2 A fuse in series with the positive +24 VDC lead to protect internal circuitry against overcurrent conditions.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.