{"product_id":"nktm01-10-abb-bailey-infi-90-ribbon-cable-module","title":"NKTM01-10 ABB Bailey Infi 90 Ribbon Cable Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB NKTM01-10\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNKTM01\u003c\/strong\u003e Ribbon Cable Module, operates as a dedicated hardware component for internal logic bus interconnections and signal routing within Bailey Infi 90 processing chassis. It links functional I\/O processing modules directly to targeted termination modules using a multi-conductor ribbon layout, providing continuous signal propagation rated at 300 V AC and up to 1 A per conductor.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown \u0026amp; Configuration Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNKTM01\u003c\/strong\u003e: Base designator for Bailey Infi 90 flat ribbon cable termination assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-10\u003c\/strong\u003e: Specific physical length variant (10 ft nominal rating \/ 10 in physical connection span) engineered for cabinet routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Specification\u003c\/strong\u003e: 28 AWG multi-conductor flat ribbon wire construction supporting low-current instrumentation signals up to 1 A per line.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Specifications \u0026amp; Environmental Limits\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNKTM01-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSWEDEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e12 x 3 x 9.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive ribbon assembly (0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e1 A per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Gauge\u003c\/td\u003e\n\u003ctd\u003e28 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5-95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Architecture \u0026amp; Bus Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe NKTM01-10 cable assembly preserves backplane bus communication velocity and optimizes high-density I\/O density scaling within Bailey Infi 90 enclosures. The uniform spacing of the 28 AWG ribbon conductors prevents inter-channel crosstalk during rapid digital state transitions. This physical routing stability maintains system-wide firmware flash compatibility and prevents data packet corruptions across interconnected process cards during online operations.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB NKTM01-10 Ribbon Cable Module Assembly\u003c\/li\u003e\n\u003cli\u003eProtective connector dust covers in sealed anti-static bag\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Routing \u0026amp; Handling Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeader Insertion\u003c\/strong\u003e: Press ribbon connector headers straight into the module sockets until the side locking clips fully snap into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrease Avoidance\u003c\/strong\u003e: Avoid sharp right-angle folds or crimping along the ribbon cable body; enforce a minimum bend radius of 25 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRouting Isolation\u003c\/strong\u003e: Route ribbon cables in dedicated wireways separate from high-voltage AC lines and high-current relay outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrain Relief\u003c\/strong\u003e: Fasten the ribbon assembly using plastic mounting clamps near termination points to prevent mechanical stress on pin joints.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Technical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum current capacity per conductor for the NKTM01-10?\u003c\/p\u003e\n\u003cp\u003eEach 28 AWG conductor within the flat ribbon assembly is rated for a maximum continuous current of 1 A at 300 V AC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the NKTM01-10 ribbon cable be hot-swapped during live controller operation?\u003c\/p\u003e\n\u003cp\u003eUnplugging active ribbon cables breaks internal bus paths and will cause immediate controller I\/O faults; power down the section first.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the 28 AWG conductor gauge impact signal transmission?\u003c\/p\u003e\n\u003cp\u003eThe 28 AWG wire size is optimized for low-current logical signal paths, ensuring minimal capacitance across internal cabinet runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat thermal limits apply to the cable insulation inside enclosure cabinets?\u003c\/p\u003e\n\u003cp\u003eThe PVC jacket and connector insulation maintain dielectric integrity within ambient temperatures ranging from -20 deg C to +80 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the ribbon cable assembly include built-in grounding shields?\u003c\/p\u003e\n\u003cp\u003eThe NKTM01-10 is an unshielded flat ribbon cable; ground connections are handled via designated return lines in the header pin assignment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat failure modes result from exceeding the cable bend radius limits?\u003c\/p\u003e\n\u003cp\u003eOver-bending or creasing can fracture internal 28 AWG conductors or crack insulation, causing intermittent open circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre field length modifications permitted on NKTM01-10 assemblies?\u003c\/p\u003e\n\u003cp\u003eField trimming or re-crimping standard IDC connectors is not recommended as it risks insulation displacement alignment failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is pin alignment preserved during installation into termination units?\u003c\/p\u003e\n\u003cp\u003ePolarization keys on the ribbon connector headers prevent inverted mating and misaligned pin connections on the module board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021106499757,"sku":"NKTM01-10","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-nktu01-10-bailey-infi-90-termination-unit-cable-10-ft-1pa53y11pld.jpg?v=1766983660","url":"https:\/\/www.maxwellplc.com\/ga\/products\/nktm01-10-abb-bailey-infi-90-ribbon-cable-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}