NKAS11-12 ABB Bailey Infi 90 Analog Slave Termination Unit Cable
-
Dimensions: 38.1 x 7.6 x 33.0 cm
-
Country of origin: Sweden
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
Configured for multi-channel analog signal routing and slave termination module interconnectivity in Bailey Infi 90 DCS racks, the ABB NKAS11-12 (NKAS11 Analog Slave Termination Unit Cable) provides direct physical/electrical execution. This multi-conductor cable assembly transfers low-level voltage and current loop signals between analog slave processing cards and field termination units, supporting continuous 300 V AC insulation integrity across 16-32 conductor pathways.
Cable Part Number & Assembly Breakdown
- NKAS11: Base part designation for Bailey Infi 90 analog slave termination interconnect cables.
- -12: Extended assembly length designator (12 ft nominal length specification / 12 in physical harness span).
- Conductor Harness: Multi-conductor bundle incorporating 16-32 discrete 20-22 AWG copper lines rated for 300 V AC service.
Technical & Electrical Specifications
| Parameter | Specification |
|---|---|
| Model | NKAS11-12 |
| Brand | ABB |
| Origin | SWEDEN |
| Weight | 1.6 kg |
| Shipping Dimensions | 38.1 x 7.6 x 33.0 cm |
| Operating Temp | -20 deg C to +80 deg C |
| Power Consumption | Passive component (0 W) |
| Voltage Rating | 300 V AC |
| Conductor Gauge | 20-22 AWG |
| Number of Conductors | 16-32 conductors |
| Storage Temperature | -40 deg C to +85 deg C |
| Humidity | 5-95% RH (non-condensing) |
| Tariff Code | 8537101190 |
Deterministic IO Bus Routing & Signal Integrity
The NKAS11-12 assembly supports structured backplane bus communication velocity and I/O density scaling across Infi 90 analog expansion racks. Low-resistance 20-22 AWG copper conductors limit loop impedance and prevent channel crosstalk during multi-channel signal multiplexing. The assembly preserves precise analog-to-digital measurement accuracy and maintains firmware flash compatibility across connected slave modules during continuous online operations.
Package & Ordering Components
- 1 x ABB NKAS11-12 Analog Slave Termination Unit Cable
- Factory ESD protective polybag packaging
Cabinet Cable Installation Guidelines
- Connector Engagement: Insert terminal connectors fully into mating module headers and tighten retaining screws to establish low-resistance electrical contacts.
- Bend Radius Limits: Maintain a minimum static cable bend radius of 75 mm inside wireways to prevent conductor stress and insulation degradation.
- Signal Cable Separation: Route the analog slave cable bundle at least 200 mm clear of AC power wiring and high-current relay circuits to mitigate noise coupling.
- Strain Relief: Secure the cable harness to cabinet tie-down points within 100 mm of the connection header to eliminate mechanical pull on terminal pins.
Technical Support FAQ
-
What is the primary application of the NKAS11-12 cable assembly?
It provides multi-channel analog signal connections between slave processing modules and field termination blocks in Infi 90 racks.
-
What voltage isolation rating applies to the individual conductors?
Each conductor in the assembly features high-dielectric insulation rated for continuous operation at 300 V AC.
-
Can the cable assembly be disconnected while the host module is powered?
Disconnecting live cables breaks analog loops, triggering open-circuit diagnostic alarms on active controller channels.
-
How does conductor resistance affect measurement accuracy across this cable?
The 20-22 AWG wire gauge minimizes series loop resistance, preserving voltage drops and 4-20 mA calibration limits.
-
Does the NKAS11-12 require separate external shield grounding wires?
Internal cable shields connect automatically to system chassis earth through dedicated ground pins on the header connector.
-
What is the ambient temperature threshold for installed cable runs?
The physical cable assembly operates continuously in ambient field temperatures from -20 deg C up to +80 deg C.
-
How does the cable construction prevent internal signal crosstalk?
Conductors are arranged in twisted pairs with overall shielding to isolate adjacent analog channels from mutual induction.
-
How should spare cable harness length be stored within marshalling racks?
Coil excess cable in loose loops with a minimum diameter of 200 mm to preserve conductor insulation and shielding integrity.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.