KFD2-STC5-Ex1.20 Pepperl+Fuchs SMART Transmitter Power Supply K-System
-
Dimensions: 20 x 124 x 115 mm
-
Country of origin: Germany
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
Configured for isolated 4-20 mA signal conditioning in hazardous-area instrumentation, the Pepperl+Fuchs KFD2-STC5-Ex1.20 (KFD2-STC5-Ex1.20 SMART Transmitter Power Supply) supplies 2-wire and 3-wire SMART transmitters and transfers one field input to two galvanically isolated control-side outputs. The device supports HART, BRAIN, and Foxboro protocols.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | KFD2-STC5-Ex1.20 |
| Brand | Pepperl+Fuchs |
| Product Type | SMART Transmitter Power Supply / Isolated Barrier |
| Series | K-System |
| Origin | Germany |
| Weight | Approx. 200 g |
| Shipping Dimensions | 20 x 124 x 115 mm housing dimensions; shipping carton dimensions not specified by manufacturer |
| Operating Temp | -20 to 60 deg C; extended range up to 70 deg C with specified mounting conditions |
| Power Consumption | <= 1.7 W at maximum load |
| Supply Voltage | 18 to 30 V DC |
| Supply Connection | Power Rail or terminals 14+, 15- |
| Input Signal | 4-20 mA |
| Input Connection | Terminals 1+, 2-, 3 |
| Input Resistance | Max. 265 ohm at terminals 2-, 3; max. 330 ohm at terminals 1+, 3 |
| Output Signal | 4-20 mA |
| Number of Outputs | 2 isolated outputs |
| Output Load | 0 to 600 ohm |
| Output Connection | Terminals 7, 8, 9 and 10, 11, 12 |
| Output Mode | Current sink or current source |
| Output Ripple | Max. 50 uA rms |
| External Loop Supply | 2 to 30 V DC |
| Internal HART Resistor | 250 ohm at terminals 9 and 12 |
| Settling Time | 500 us |
| Rise/Fall Time | 100 us |
| Bandwidth | 0 to 7.5 kHz field-to-control; 0.3 to 7.5 kHz control-to-field at 0.5 Vpp |
| Galvanic Isolation | Input/output and input/power supply safe electrical isolation, peak voltage 375 V |
| Protection Rating | IP20 |
| Mounting | 35 mm DIN mounting rail according to EN 60715 |
| Connection Type | Screw terminals |
| Display | Green LED for power supply |
| Safety Integrity Level | SIL 3 |
| Systematic Capability | SC 3 |
| Hazardous Area Input | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
| Hazardous Area Output | Ex ec IIC T4 Gc |
| ATEX Certificate | CML 17 ATEX 2031X / CML 17 ATEX 3030X |
| IECEx Certificate | IECEx CML 17.0016X |
The manufacturer specifies a 20 x 124 x 115 mm housing and approximately 200 g mass. The dimensions correspond to the installed housing rather than an external shipping carton.
Intrinsic Safety and Signal Isolation
The KFD2-STC5-Ex1.20 is a 1-channel isolated barrier with a signal-splitter function. The field-side 4-20 mA input can supply 2-wire or 3-wire SMART transmitters and 2-wire SMART current sources. The control side provides two isolated 4-20 mA outputs.
Both control-side outputs can be configured independently as current sink or current source outputs. The internal 250 ohm resistors at terminals 9 and 12 can provide the HART communication resistance where required by the control circuit. HART digital communication superimposed on the analog signal is transferred bidirectionally.
The device supports HART, BRAIN, and Foxboro SMART protocols. The specified intrinsic-safety parameters include a maximum safe voltage of 250 V and input-side entity parameters including Uo of 26.2 V, Io of 93 mA, and Po of 634 mW for the applicable terminal arrangement.
Ordering Information
- Model: KFD2-STC5-Ex1.20
- Product family: K-System isolated barriers
- Device type: SMART Transmitter Power Supply
- Standard device configuration: 1 field-side input and 2 isolated control-side outputs
- Mounting: 35 mm DIN mounting rail
- Connection: Removable screw terminals
- Power supply: 18 to 30 V DC through Power Rail or terminals 14+, 15-
- Supplied configuration should be checked against the applicable Pepperl+Fuchs ordering documentation and hazardous-area certificates.
Field Installation Guidelines
DIN-rail mounting
- Install the module on a 35 mm DIN mounting rail according to EN 60715.
- Maintain the manufacturer-specified mounting conditions when operating at the extended temperature range up to 70 deg C.
- Provide sufficient access to the removable terminals for wiring and service.
Signal wiring
- Connect the field-side 4-20 mA circuit to terminals 1+, 2-, and 3 according to the applicable wiring diagram.
- Route hazardous-area signal wiring separately from non-intrinsically-safe circuits where required by the installation design.
- Use the appropriate shield termination method defined by the plant grounding and intrinsic-safety installation standard.
- Verify transmitter loop polarity and available voltage before commissioning.
Control-side wiring
- Select sink or source operation according to the receiving input circuit.
- Observe the specified 0 to 600 ohm output load range.
- Use the internal 250 ohm resistor when required for HART communication resistance.
- Unused outputs may be short-circuited to reduce internal power dissipation by up to 100 mW per channel, according to the manufacturer documentation.
Delivery Information
- Delivery time: 3-5 days when payment is finished.
- Shipping: DHL, FedEx, or UPS.
- Packaging: anti-static industrial packaging with impact protection for industrial electronic equipment.
Frequently Asked Questions
Q: What type of input signal does the KFD2-STC5-Ex1.20 accept?
A: The field-side input is a 4-20 mA analog signal and supports 2-wire and 3-wire SMART transmitters as well as 2-wire SMART current sources.
Q: How many control-side outputs are provided?
A: Two isolated 4-20 mA outputs are provided. Each output can operate in current sink or current source mode.
Q: Does the module support HART communication?
A: Yes. HART signals superimposed on the analog signal can be transferred bidirectionally. Test sockets for HART communicators are integrated into the terminals.
Q: What is the specified output load range?
A: The control-side output load range is 0 to 600 ohm. The internal 250 ohm resistor can be used as a load for HART communication.
Q: What are the operating temperature limits?
A: The specified ambient operating temperature is -20 to 60 deg C. An extended range up to 70 deg C is permitted when the mounting conditions specified in the manual are followed.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.