H8PS-32B Omron H8PS Series Cam Positioner
-
Dimensions: 96 mm x 96 mm x 67.5 mm
-
Country of origin: Japan
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
The Omron H8PS-32B serves as the primary H8PS Cam Positioner utilized to execute absolute rotary encoder signal evaluation and output switching across high-density motion control platforms.
Model Number Structure
- H8PS: Series identifier for panel-mounted electronic cam positioner units.
- 32: Designates 32-channel discrete NPN transistor output capacity.
- B: Denotes panel-mount construction with 1/4 DIN outer dimensions (96 x 96 mm) and integrated backlit LCD display.
Physical and Electrical Specifications
| Parameter | Specification |
|---|---|
| Model | H8PS-32B |
| Brand | Omron |
| Origin | Japan |
| Weight | Approx. 300 g |
| Shipping Dimensions | 96 mm x 96 mm x 67.5 mm |
| Operating Temp | -10 to 55 deg C |
| Supply Voltage AC | 20.4-26.4 V |
| Power Consumption | Approx. 15 VA max. |
| Form Factor | 1/4 DIN (96 x 96 mm) |
| Display Type | LCD with backlight |
| Inputs | Absolute Encoder |
| Output Type | NPN transistor (32 outputs) |
Industrial Motion Bus Processing and Logic Scaling
Internal signal execution circuits handle high-speed angle decoding from connected absolute encoders to manage elevated I/O density scaling across complex multi-axis automation cells. Digital comparator logic compares encoder positioning against pre-set angular limits, maintaining backplane bus communication velocity Licences and ensuring persistent firmware flash compatibility for stored program parameters during power interruptions.
Package Component List
- 1 x Omron H8PS-32B Cam Positioner Assembly
- 1 x Panel Mounting Adapter Clamp
- 1 x Protective Terminal Guard
- 1 x Panel Waterproof Rubber Gasket
Field Installation Protocols
Panel Cutout Preparation
Cut a standard 1/4 DIN (92 x 92 mm) square cutout on the control cabinet door. Mount the unit through the front cutout with the waterproof rubber gasket fitted between the bezel and panel door to maintain front sealing.
Encoder Direction Configuration
Locate the onboard DIP switches on the housing. Set the designated switch to forward (CW) or reverse (CCW) phase decoding to match the physical rotation direction of the connected absolute encoder.
Terminal Wiring and Output Grounding
Connect the 20.4-26.4 VAC supply conductors to the AC power terminals. Wire the 32 discrete NPN open-collector outputs to PLC inputs or relay modules, ensuring proper functional earth (FG) grounding for shield drain wires to prevent noise coupling.
Technical FAQ
-
How is encoder direction inversion executed on the hardware level?
An internal DIP switch changes logic decoding phases between Clockwise (CW) and Counter-Clockwise (CCW) without physically swapping input signal leads.
-
What internal protection preserves program data when power is lost?
EEPROM non-volatile memory stores all 32-channel ON/OFF angle settings permanently without reliance on an internal backup battery.
-
What occurs if the absolute encoder signal cable is severed?
The positioner logic detects loss of encoder pulses, immediately disables all 32 NPN transistor outputs, and displays an encoder alarm code on the LCD.
-
Can the 32 NPN transistor outputs be wired directly to inductive loads?
Outputs require external flyback diode protection when switching inductive loads like relay coils to prevent voltage transients from damaging output transistors.
-
Is hot-swapping the encoder terminal block permitted during operation?
Unplugging or plugging the encoder interface while AC power is applied risks damaging internal logic circuitry and causing output state glitches.
-
What grounding practice prevents signal corruption on the encoder line?
Connect the encoder cable shield to the dedicated Functional Ground (FG) terminal on the positioner end only to avoid ground loop currents.
-
What clearance is necessary around the panel housing for thermal safety?
Leave at least 30 mm clear space above and below the rear enclosure inside the cabinet to permit heat dissipation from internal power components.
-
What voltage range is acceptable on the AC power terminals?
The power circuit operates between 20.4 and 26.4 VAC; supplying voltage outside this tolerance can cause system fault trips or hardware failure.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.