{"product_id":"h7cx-a4w-n-omron-h7cx-series-multifunction-counter","title":"H7CX-A4W-N Omron H7CX Series Multifunction Counter","description":"\u003cp\u003eThe \u003cstrong\u003eOmron H7CX-A4W-N\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eH7CX\u003c\/strong\u003e Multifunction Counter, operates as a dedicated hardware component for high-speed pulse acquisition and dual-stage preset control within industrial automated control panels.\u003c\/p\u003e\n\u003ch3\u003ePart Number Nomenclature \u0026amp; Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eH7CX\u003c\/strong\u003e: Designates the standard 48 mm x 48 mm DIN digital counter\/tachometer hardware platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Standard screw-terminal block connection interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: 4-digit display capacity (0 to 9999 display range).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eW\u003c\/strong\u003e: 2-stage preset output configuration with dual control contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-N\u003c\/strong\u003e: Upgraded design generation featuring high-contrast display panel and improved configuration parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Functional Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eH7CX-A4W-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e4.8 cm x 4.8 cm x 8.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e9.2 VA max at 100 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Digits\u003c\/td\u003e\n\u003ctd\u003e4 digits (-999 to 9999)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Counting Speed\u003c\/td\u003e\n\u003ctd\u003e30 Hz or 5 kHz (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e2-stage transistor\/relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHigh-Density I\/O \u0026amp; Bus Data Throughput\u003c\/h3\u003e\n\u003cp\u003eThe counter module executes direct high-speed input pulse sampling, maintaining optimal I\/O density scaling across discrete panel assemblies. Internal register execution operates with high firmware flash compatibility to preserve setpoint configurations during power loss. Signal filtering stages prevent contact bounce interference while maintaining deterministic processing across high-density I\/O switching circuits.\u003c\/p\u003e\n\u003ch3\u003eStandard Delivery Content\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron H7CX-A4W-N Counter Unit\u003c\/li\u003e\n\u003cli\u003e1 x Panel Mounting Adapter\u003c\/li\u003e\n\u003cli\u003e1 x Waterproof Packing Seal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Installation \u0026amp; Wiring Protocol\u003c\/h3\u003e\n\u003ch4\u003ePanel Cutout \u0026amp; IP Configuration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePrepare a standard 45.0 mm x 45.0 mm panel cutout for flush-mount installation.\u003c\/li\u003e\n\u003cli\u003eVerify the waterproof packing gasket is aligned around the front housing bezel to achieve IP66 front-panel protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePower Supply \u0026amp; Signal Wiring\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConnect 100 to 240 VAC utility power to designated screw terminals using ring or spade lugs.\u003c\/li\u003e\n\u003cli\u003eKeep sensor signal input lines physically separated from high-current AC motor leads by a minimum distance of 50 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEarth Grounding \u0026amp; Shielding\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eTerminate input cable shielding to a clean single-point functional earth ground terminal inside the panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Questions \u0026amp; Answers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the display digit capacity on the H7CX-A4W-N model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe front display panel provides a 4-digit visual readout covering a range from -999 to 9999.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat counting speeds can be selected for input pulse processing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInput response speed is configurable via software parameters to either 30 Hz or 5 kHz max.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply voltage is required to operate the counter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit accepts a wide AC power input ranging from 100 to 240 VAC at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow are output control functions configured on this specific model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe -W suffix indicates a 2-stage preset configuration with independent stage setpoints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the total mass weight of the unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe hardware unit has a net weight of approximately 0.13 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat ingress protection level does the front panel offer when properly installed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen mounted using the supplied rubber packing seal, the front panel meets IP66 protection standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAre configuration settings retained during an unannounced power failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInternal non-volatile memory retains all user setpoints and system parameters without battery power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is electrical noise prevented on sensitive input channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShielded wiring must be used for input leads, routed separately from high-voltage AC cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306677649581,"sku":"H7CX-A4W-N","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/H7CX-A4W-N.jpg?v=1789712359","url":"https:\/\/www.maxwellplc.com\/ga\/products\/h7cx-a4w-n-omron-h7cx-series-multifunction-counter","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}