{"product_id":"h7cx-a11d1-n-omron-multifunction-counter-tachometer-h7cx-series","title":"H7CX-A11D1-N Omron Multifunction Counter\/Tachometer H7CX Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron H7CX-A11D1-N\u003c\/strong\u003e serves as the primary \u003cstrong\u003eH7CX\u003c\/strong\u003e Multifunction Counter\/Tachometer utilized to execute high-speed pulse processing, discrete preset switching, and frequency evaluation across automated machine automation platforms.\u003c\/p\u003e\n\u003ch3\u003ePart Number Nomenclature \u0026amp; Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eH7CX\u003c\/strong\u003e: Base platform series for standard 48 x 48 mm DIN digital counter\/tachometer instruments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Standard function profile configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e11\u003c\/strong\u003e: 11-pin circular socket rear terminal connection layout\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD1\u003c\/strong\u003e: Low-voltage operating power supply rating of 12 to 24 VDC \/ 24 VAC (50\/60 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigits (Unspecified\/None)\u003c\/strong\u003e: 6-digit 7-segment negative transmissive LCD layout (0 to 999999)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSettings (Unspecified\/None)\u003c\/strong\u003e: Single-stage preset configuration profile\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type (Unspecified\/None)\u003c\/strong\u003e: Contact output relay or combined relay\/transistor switching arrangement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN\u003c\/strong\u003e: Updated hardware platform revision designation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Performance Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eH7CX-A11D1-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.13 kg (Shipping weight: 2.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e4.8 cm x 8.41 cm x 4.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 4.2 VA max. (24 VAC) \/ 2.5 W max. (12 to 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e12 to 24 VDC \/ 24 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85% to 110% of rated supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Capacity\u003c\/td\u003e\n\u003ctd\u003e6 digits (0 to 999999)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Modes\u003c\/td\u003e\n\u003ctd\u003eIncrement, Decrement, Command, Individual, Phase Difference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Output\u003c\/td\u003e\n\u003ctd\u003eRelay contact output (250 VAC \/ 30 VDC, 3 A resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Interface\u003c\/td\u003e\n\u003ctd\u003e11-pin circular socket connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Routing \u0026amp; Internal Hardware Architecture\u003c\/h3\u003e\n\u003cp\u003eInternal signal conditioning stages execute input pulse accumulation and tachometer frequency sampling with deterministic response timings. EEPROM memory retention guarantees firmware flash compatibility and retains internal parameter registries across power interruption cycles without auxiliary battery support. Standardized I\/O scaling supports signal conversion and transmission to programmable logic controllers across Profinet and EtherNet\/IP deterministic networks via external fieldbus adapter interfaces.\u003c\/p\u003e\n\u003ch3\u003eShipping Package \u0026amp; Component Manifest\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron H7CX-A11D1-N Counter\/Tachometer Unit\u003c\/li\u003e\n\u003cli\u003e1 x Panel Mounting Adapter Bracket Assembly\u003c\/li\u003e\n\u003cli\u003e1 x Waterproof Gasket Ring\u003c\/li\u003e\n\u003cli\u003e1 x Installation Sheet \u0026amp; Panel Cutout Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePanel Mounting \u0026amp; Terminal Wiring Procedures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Cutout Fitting\u003c\/strong\u003e Prepare a standard 45 x 45 mm square panel opening. Place the rubber sealing gasket over the instrument housing, insert the unit through the front panel cut, and lock the mounting sleeve from the rear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e11-Pin Base Connection\u003c\/strong\u003e Wire the external circular socket (e.g., P2CF-11) prior to plugging in the module. Ensure strict adherence to pin designations for 12-24 VDC \/ 24 VAC supply terminals and sensor inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Cable Noise Suppression\u003c\/strong\u003e Route sensor input leads in separate grounded metallic conduits away from high-voltage AC mains and variable frequency drive outputs to prevent noise-induced pulse counting errors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage inputs are supported by the H7CX-A11D1-N?\u003c\/p\u003e\n\u003cp\u003eThe instrument operates directly on low-voltage power feeds of 12 to 24 VDC or 24 VAC at 50\/60 Hz, within an allowable window of 85% to 110% rated voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many display digits are available on this model variant?\u003c\/p\u003e\n\u003cp\u003eThis model features a 6-digit backlit negative transmissive LCD display stage supporting count ranges from 0 to 999999.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical socket interface is required for panel wiring?\u003c\/p\u003e\n\u003cp\u003eThe unit utilizes a standard 11-pin circular socket base (such as the Omron P2CF-11 or P3GA-11) for external wiring terminations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are control parameters preserved during supply voltage loss?\u003c\/p\u003e\n\u003cp\u003eAll preset values, operating modes, and totalized counts are saved continuously into non-volatile EEPROM memory without requiring battery maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat control output switching mechanisms are available?\u003c\/p\u003e\n\u003cp\u003eThe module provides electromechanical relay contact switching rated for up to 250 VAC or 30 VDC at 3 A under resistive loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the input stage handle quadrature encoder signals?\u003c\/p\u003e\n\u003cp\u003eYes, the internal input processing circuit supports phase difference (quadrature) inputs alongside standard increment and decrement pulse signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ambient temperature range is specified for cabinet operation?\u003c\/p\u003e\n\u003cp\u003eThe instrument is designed to maintain rated counting accuracy in ambient cabinet temperatures ranging from -10 to 55 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the standard panel cutout size for flush-mount installation?\u003c\/p\u003e\n\u003cp\u003eThe unit fits into a standard DIN 45 x 45 mm panel cutout and is secured from the rear using the included panel mounting adapter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306610278573,"sku":"H7CX-A11D1-N","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/H7CX-A11D1-N-1.jpg?v=1789998480","url":"https:\/\/www.maxwellplc.com\/ga\/products\/h7cx-a11d1-n-omron-multifunction-counter-tachometer-h7cx-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}