{"product_id":"ge-fanuc-ic695psa140e-pacsystems-rx3i-40w-power-supply","title":"GE Fanuc IC695PSA140E PACSystems RX3i 40W Power Supply","description":"\u003cp\u003eThe GE Fanuc IC695PSA140E is a 40W multi-purpose power supply for PACSystems RX3i Universal Backplanes. It accepts 85–264 VAC or 100–300 VDC input and provides +5.1 VDC, +24 VDC relay power, and +3.3 VDC outputs. Revision E incorporates improvements to undervoltage detection during power-up and a RoHS-related product update. The module supports load-sharing and redundancy configurations when installed according to the RX3i system requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC695PSA140E belongs to the GE Fanuc PACSystems RX3i PLC product family. It supplies power to the RX3i Universal Backplane and compatible IC695-series modules.\u003c\/p\u003e\n\u003cp\u003eThe power supply provides three output rails:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e+5.1 VDC:\u003c\/strong\u003e Supplies power to the RX3i backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e+24 VDC:\u003c\/strong\u003e Provides relay power for compatible output relay modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e+3.3 VDC:\u003c\/strong\u003e Supplies internal power to modules with IC695 catalog numbers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module occupies two backplane slots. Multiple compatible PSA140 and PSD140 power supplies can be used for load-sharing or redundancy, subject to the system's power configuration and compatibility restrictions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e40W total output power capacity\u003c\/li\u003e\n\u003cli\u003e120\/240 VAC or 125 VDC nominal input\u003c\/li\u003e\n\u003cli\u003eWide AC and DC input voltage ranges\u003c\/li\u003e\n\u003cli\u003eThree output rails: +5.1 VDC, +24 VDC, and +3.3 VDC\u003c\/li\u003e\n\u003cli\u003eSupports load-sharing and redundancy applications\u003c\/li\u003e\n\u003cli\u003eSupports up to four compatible PSA140\/PSD140 supplies in an RX3i Universal Backplane\u003c\/li\u003e\n\u003cli\u003eFour status indicators for power, power-supply fault, overtemperature, and overload\u003c\/li\u003e\n\u003cli\u003eInput-to-backplane electrical isolation\u003c\/li\u003e\n\u003cli\u003eTwo-slot Universal Backplane installation\u003c\/li\u003e\n\u003cli\u003eRevision E improvements to power-up undervoltage detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC695PSA140E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMulti-Purpose Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC or 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Range\u003c\/td\u003e\n\u003ctd\u003e85–264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Range\u003c\/td\u003e\n\u003ctd\u003e100–300 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Power\u003c\/td\u003e\n\u003ctd\u003e70 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Output Power\u003c\/td\u003e\n\u003ctd\u003e40 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+5.1 VDC Output\u003c\/td\u003e\n\u003ctd\u003e5.0–5.2 VDC, 6 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+3.3 VDC Output\u003c\/td\u003e\n\u003ctd\u003e3.1–3.5 VDC, 9 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+24 VDC Relay Output\u003c\/td\u003e\n\u003ctd\u003e19.2–28.8 VDC, 1.6 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Power at 5.1 VDC\u003c\/td\u003e\n\u003ctd\u003e30 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Power at 3.3 VDC\u003c\/td\u003e\n\u003ctd\u003e30 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e4 A, 250 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput-to-Backplane Isolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ripple\u003c\/td\u003e\n\u003ctd\u003e150 mV maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Noise\u003c\/td\u003e\n\u003ctd\u003e150 mV maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRide-Through Time\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Wire Size\u003c\/td\u003e\n\u003ctd\u003e14–22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Terminal\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Occupancy\u003c\/td\u003e\n\u003ctd\u003e2 slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Backplane\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i IC695 Universal Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Compatible Supplies\u003c\/td\u003e\n\u003ctd\u003eUp to 4 PSA140\/PSD140 supplies per Universal Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Sharing\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupported, subject to compatibility restrictions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003ePower, P\/S Fault, Overtemperature, Overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5–95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 50.8 × 130 × 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eRevision E Identification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC695PSA140E is a specific hardware revision of the IC695PSA140 power supply.\u003c\/p\u003e\n\u003cp\u003eIts documented revision history includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMay 2013:\u003c\/strong\u003e Increased the margin of the 5 V and 3.3 V undervoltage detectors to help prevent power-supply faults during the power-up sequence.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJanuary 2016:\u003c\/strong\u003e RoHS conversion update with applicable exemptions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese changes do not alter the module's form, fit, or function. When sourcing a replacement, check the complete catalog number and revision marking on the product label.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLoad Sharing and Redundancy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC695PSA140E supports load-sharing and redundant power configurations in compatible PACSystems RX3i Universal Backplanes.\u003c\/p\u003e\n\u003cp\u003eUp to four compatible PSA140 and\/or PSD140 supplies can be installed in a Universal Backplane. This arrangement can provide additional power capacity or power-source redundancy, depending on the system design.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant compatibility restriction:\u003c\/strong\u003e The IC695PSA140 cannot be used with IC695PSA040 or IC695PSD040 power supplies in redundant or increased-capacity configurations. Always check the installed power-supply combination before changing the rack configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLED Indicators and Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe front panel provides four status indicators for monitoring power-supply operation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePOWER:\u003c\/strong\u003e Green indicates that power is being supplied to the backplane. Amber indicates that input power is present but the supply switch is off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP\/S FAULT:\u003c\/strong\u003e Red indicates that the power supply has failed to provide sufficient backplane voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOVERTEMP:\u003c\/strong\u003e Amber indicates that the power supply is approaching or exceeding its maximum operating temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOVERLOAD:\u003c\/strong\u003e Amber indicates that at least one output is approaching or exceeding its maximum capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe RX3i CPU can detect internal power-supply faults and record the corresponding fault information.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Wiring Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC695PSA140E is designed for installation in a compatible PACSystems RX3i Universal Backplane.\u003c\/p\u003e\n\u003cp\u003eBefore installation, confirm the rack configuration and available power capacity.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eVerify that the backplane is an IC695 Universal Backplane.\u003c\/li\u003e\n\u003cli\u003eConfirm that the selected power-supply combination supports the intended load-sharing or redundancy arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the AC or DC input source against the specified voltage range.\u003c\/li\u003e\n\u003cli\u003eUse suitable 14–22 AWG copper wiring for the input terminals.\u003c\/li\u003e\n\u003cli\u003eFollow the specified terminal torque and grounding requirements in the installation manual.\u003c\/li\u003e\n\u003cli\u003eKeep the protective terminal cover closed during normal operation.\u003c\/li\u003e\n\u003cli\u003eAfter energizing the system, check all four LED indicators and confirm that the backplane receives the required power.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e The AC input terminals can carry hazardous voltage. Isolate the power source before wiring, replacing, or servicing the module. Follow the manufacturer's installation procedures and applicable electrical safety requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC695PSA140E is used in industrial automation systems built around the PACSystems RX3i PLC platform.\u003c\/p\u003e\n\u003cp\u003eTypical applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower generation and electrical control systems\u003c\/li\u003e\n\u003cli\u003eIndustrial manufacturing automation\u003c\/li\u003e\n\u003cli\u003eProcess control installations\u003c\/li\u003e\n\u003cli\u003eOil and gas facilities\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment\u003c\/li\u003e\n\u003cli\u003eChemical and petrochemical plants\u003c\/li\u003e\n\u003cli\u003ePLC control cabinet power distribution\u003c\/li\u003e\n\u003cli\u003eRedundant and load-sharing control system architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC695PSA140E is designed for GE Fanuc PACSystems RX3i Universal Backplanes using IC695-series modules.\u003c\/p\u003e\n\u003cp\u003eBefore ordering or replacing this power supply, verify:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe installed backplane catalog number\u003c\/li\u003e\n\u003cli\u003eTotal backplane power requirements\u003c\/li\u003e\n\u003cli\u003eExisting power-supply models and revisions\u003c\/li\u003e\n\u003cli\u003eLoad-sharing or redundancy configuration\u003c\/li\u003e\n\u003cli\u003eAC or DC input requirements\u003c\/li\u003e\n\u003cli\u003eCompatibility with other installed power supplies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not assume that the IC695PSA140E is interchangeable with the IC695PSA040 or IC695PSD040 in redundant or increased-capacity configurations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBenefits of Correct Replacement Selection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSelecting the correct power-supply revision helps maintain the intended RX3i backplane power configuration. Revision E also incorporates documented improvements to undervoltage detection during power-up.\u003c\/p\u003e\n\u003cp\u003eFor maintenance planning, confirm the complete part number, input voltage, output capacity, and existing rack configuration. These checks help reduce installation errors and avoid incompatible power-supply combinations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the GE Fanuc IC695PSA140E?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is a 40W multi-purpose power supply for GE Fanuc PACSystems RX3i Universal Backplanes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What input voltage does the IC695PSA140E support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt supports 85–264 VAC or 100–300 VDC input. Its nominal ratings are 120\/240 VAC or 125 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What are the output voltages?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module provides +5.1 VDC, +24 VDC relay power, and +3.3 VDC outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. What is the total output power capacity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe power supply provides up to 40W total output power. The available capacity depends on the output loading and operating conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. What is the difference between IC695PSA140 and IC695PSA140E?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC695PSA140E is a later hardware revision. Its documented changes include improved 5 V and 3.3 V undervoltage detection and a RoHS conversion update.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. Can multiple IC695PSA140E modules be installed in one rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Up to four compatible PSA140 and\/or PSD140 supplies can be used in an RX3i Universal Backplane, subject to the system configuration and power requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. Is the IC695PSA140E suitable for redundant applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It supports load-sharing and redundancy configurations. However, it cannot be used with IC695PSA040 or IC695PSD040 in redundant or increased-capacity configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. Which LED indicators are available?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe front panel provides POWER, P\/S FAULT, OVERTEMP, and OVERLOAD indicators for monitoring operating status.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRelated Products\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGE Fanuc IC695PSD140 – PACSystems RX3i 40W DC Power Supply\u003c\/li\u003e\n\u003cli\u003eGE Fanuc IC695PSA140 – PACSystems RX3i 40W Multi-Purpose Power Supply\u003c\/li\u003e\n\u003cli\u003eGE Fanuc IC695PSA040 – PACSystems RX3i 40W Power Supply\u003c\/li\u003e\n\u003cli\u003eGE Fanuc IC695CHS007 – RX3i 7-Slot Universal Backplane\u003c\/li\u003e\n\u003cli\u003eGE Fanuc IC695CHS012 – RX3i 12-Slot Universal Backplane\u003c\/li\u003e\n\u003cli\u003eGE Fanuc IC695CHS016 – RX3i 16-Slot Universal Backplane\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":68381504176301,"sku":"IC695PSA140E","price":599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/IC695PSA140E-1.jpg?v=1795157374","url":"https:\/\/www.maxwellplc.com\/ga\/products\/ge-fanuc-ic695psa140e-pacsystems-rx3i-40w-power-supply","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}