Configured for timed safety output expansion in G9SX safety control systems, the Omron G9SX-EX041-T-RT (G9SX-EX041-T-RT Flexible Safety Unit) provides direct physical execution of OFF-delayed shutdown commands across connected machine automation safety circuits.
Part Nomenclature & Designation Architecture
-
G9SX: Core family identity for modular flexible safety units
-
EX: Functional classification indicating expansion unit hardware
-
0: Zero instantaneous safety output channels
-
4: 4 OFF-delayed safety output channels
-
1: 1 auxiliary monitoring output channel
-
T: Maximum OFF-delay timing control integration
-
RT: Removable screw terminal interface configuration
Physical & Electrical Performance Data
| Parameter | Specification |
| Model | G9SX-EX041-T-RT |
| Brand | Omron |
| Origin | Japan |
| Weight | 0.165 kg |
| Shipping Dimensions | 115 mm x 25 mm x 125 mm |
| Operating Temp | -10 to 55 deg C |
| Power Consumption | 2 W max. |
| Rated Supply Voltage | 24 VDC |
| Operating Voltage Range | -15% to 10% of rated supply voltage |
| Rated Load | 250 VAC, 3 A / 30 VDC, 3 A (resistive load) |
| Rated Carry Current | 3 A |
| Maximum Switching Voltage | 250 VAC, 125 VDC |
| Operating Time (OFF to ON) | 30 ms max. |
| Response Time (ON to OFF) | 10 ms max. |
| Electrical Durability | 100,000 cycles min. (rated load, 1,800 cycles/hour) |
| Mechanical Durability | 5,000,000 cycles min. (7,200 cycles/hour) |
| Vibration Resistance | 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) |
Deterministic Internal Bus & Signal Isolation Architecture
The module utilizes dedicated side-connector backplane bus communication velocity to link directly with master safety controllers, maintaining execution synchronism without relying on external network protocols like EtherNet/IP or Profinet. Channel-to-channel internal galvanic isolation shields control electronics from field contact transients. Firmware flash compatibility across the G9SX platform guarantees fixed safety loop timing, maintaining strict compliance during deterministic safety trip sequences.
Package & Supply List
-
1 x Omron G9SX-EX041-T-RT Flexible Safety Expansion Block
-
1 x Factory-Mounted Screw Terminal Block Assembly
-
1 x Technical Installation Instruction Leaflet
Field Installation & Wiring Directives
-
DIN-Rail Mounting Mount the unit vertically onto a standard 35-mm DIN rail within an enclosure offering at least IP54 ingress protection. Ensure 50-mm vertical clearance above and below for natural thermal dissipation.
-
Terminal & Cable Routing Utilize copper conductors rated for 60/75 deg C. Tighten all screw terminal connectors to a torque specification between 0.5 and 0.6 N.m to prevent loose contact arcing.
-
Electrical Separation Route safety signal lines away from heavy AC power cables and variable frequency drive motor leads to prevent electromagnetic interference.
Technical Inquiries & Operational FAQ
-
What is the principal output configuration of the G9SX-EX041-T-RT?
It provides four OFF-delayed safety outputs and one auxiliary monitoring output, with zero instantaneous safety outputs built in.
-
Does the G9SX-EX041-T-RT function as a standalone controller?
No, this expansion unit must be connected to a G9SX master unit via the dedicated internal side connector to operate properly.
-
What voltage supply is required for operation?
The unit operates on 24 VDC with an allowable operating voltage range from -15% to 10% of the rated supply voltage.
-
How fast is the ON-to-OFF response time when triggered?
The unit features a maximum ON-to-OFF response time of 10 ms, excluding any pre-configured internal OFF-delay time setting.
-
What type of wiring connections are provided on the -RT variant?
The -RT designation indicates that the unit is equipped with removable screw terminal blocks for field conductor connections.
-
What is the electrical switching capacity of the safety contacts?
The contacts handle a rated load of 250 VAC at 3 A or 30 VDC at 3 A under standard resistive load switching conditions.
-
Can this unit be hot-swapped while the system is powered?
No, main control power must be completely disconnected before attaching or removing expansion modules from the backplane bus.
-
What is the rated power consumption of the module?
The internal circuitry and output coils consume a maximum power rating of 2 W under full 24 VDC load conditions.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.