{"product_id":"g9sx-ada222-t15-rt-omron-flexible-safety-unit-g9sx-series","title":"G9SX-ADA222-T15-RT Omron Flexible Safety Unit G9SX Series","description":"\u003cp\u003eConfigured for safety input evaluation and OFF-delayed power cutoff execution in industrial machine control loops, the \u003cb\u003eOmron G9SX-ADA222-T15-RT\u003c\/b\u003e (\u003cb\u003eG9SX-ADA222\u003c\/b\u003e Flexible Safety Unit) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003ePart Number Nomenclature \u0026amp; Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eG9SX\u003c\/b\u003e: Omron standalone and expandable modular safety relay controller line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eADA\u003c\/b\u003e: Advanced Unit platform supporting logical AND expansion inputs and preset delay logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e2\u003c\/b\u003e: Instantaneous safety outputs (2 P-channel MOS FET semiconductor channels).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e2\u003c\/b\u003e: OFF-delayed safety outputs (2 P-channel MOS FET semiconductor channels).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e2\u003c\/b\u003e: Auxiliary outputs (2 PNP transistor non-safety monitoring channels).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eT15\u003c\/b\u003e: Maximum adjustable OFF-delay duration up to 15 s.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eRT\u003c\/b\u003e: Screw terminal connection block layout with pluggable terminal housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Electrical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG9SX-ADA222-T15-RT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125 mm x 115 mm x 35 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 W max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Supply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Voltage Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-15% to +10% of rated supply voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSafety Input Operating Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.4 VDC to 26.4 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSafety Input Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eapprox 2.8 kohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstantaneous Safety Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eP-channel MOS FET transistor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOFF-delayed Safety Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eP-channel MOS FET transistor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLoad Current (2 outputs or less)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 A DC max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLoad Current (3 outputs or more)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 A DC max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAuxiliary Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePNP transistor (100 mA DC max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 to 55 to 10 Hz, 0.375-mm single amplitude\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Safety Logic Execution \u0026amp; Firmware Flash Verification\u003c\/h3\u003e\n\u003cp\u003eDual internal microprocessors execute continuous cross-channel comparison routines and fault detection algorithms every operating cycle. Internal switching matrices process signals from safety inputs and AND-connection expansion buses to guarantee deterministic response states within 15 ms of signal de-energization. Integrated firmware flash routines validate hardware register states during startup power-on self-tests; any voltage sag below 20.4 VDC or cross-short detection halts output execution immediately to enforce a safe state.\u003c\/p\u003e\n\u003ch3\u003eBox Contents \u0026amp; Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Omron G9SX-ADA222-T15-RT Flexible Safety Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Pre-mounted Screw Terminal Block Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation Instruction Leaflet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Wiring \u0026amp; Panel Mounting Directives\u003c\/h3\u003e\n\u003ch4\u003eMounting Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSnap module onto standard 35-mm DIN rail in a dust-protected NEMA 12 or IP54 control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure a minimum clearance distance of 50 mm above and below the housing for heat convection and conductor routing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Wiring Controls\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eStrip wire ends 7 mm to 8 mm; tighten M3 terminal screws to a torque spec of 0.5 N-m to 0.6 N-m.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate safety input wiring from AC motor leads and switched inductive loads to eliminate electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupply logic circuits with a regulated 24 VDC PELV\/SELV power supply unit featuring surge suppression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the response latency when a safety input circuit opens?\u003c\/p\u003e\n\u003cp\u003eThe instantaneous P-channel MOS FET safety outputs switch off within a maximum response delay of 15 ms following input circuit interruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are the OFF-delay times configured on this module?\u003c\/p\u003e\n\u003cp\u003eRotary switches located on the front panel beneath the protective door adjust the OFF-delay timing incrementally up to 15 s.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat load current limits apply when all four safety outputs are active?\u003c\/p\u003e\n\u003cp\u003eWhen utilizing three or more safety outputs simultaneously, maximum load current is capped at 0.8 A DC per output channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the function of the PNP auxiliary outputs?\u003c\/p\u003e\n\u003cp\u003eAuxiliary outputs provide 100 mA non-safety status signals to standard PLCs or pilot lights for system diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the unit support expansion to add more safety outputs?\u003c\/p\u003e\n\u003cp\u003eYes, side-mounted logical AND connectors enable direct wiring-free connection to G9SX series Expansion Units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat terminal type is designated by the RT suffix?\u003c\/p\u003e\n\u003cp\u003eThe RT designation specifies M3 screw terminals housed within pluggable terminal blocks for quick replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat input voltage range maintains valid safety operation?\u003c\/p\u003e\n\u003cp\u003eThe module operates reliably across a DC supply voltage window of 20.4 VDC to 26.4 VDC (-15% to +10% tolerance).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the system signal cross-short or terminal fault conditions?\u003c\/p\u003e\n\u003cp\u003eThe red ERR indicator illuminates or flashes coded sequences on the front display to identify specific internal or external fault conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306640294061,"sku":"G9SX-ADA222-T15-RT","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/G9SX-ADA222-T15-RT_4.jpg?v=1789967512","url":"https:\/\/www.maxwellplc.com\/ga\/products\/g9sx-ada222-t15-rt-omron-flexible-safety-unit-g9sx-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}