{"product_id":"fepl-02-3abd0000072120-abb-acs-drives-ethernet-powerlink-adapter-module","title":"FEPL-02 3ABD0000072120 ABB ACS Drives Ethernet POWERLINK Adapter Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB FEPL-02 3ABD0000072120\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFEPL-02\u003c\/strong\u003e Ethernet POWERLINK adapter module, operates as a dedicated hardware component for deterministic real-time bus communication within ACS355, ACS580, ACS880, and ACS380 drive control architectures.\u003c\/p\u003e\n\u003ch3\u003eArchitecture \u0026amp; Interface Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Adapter Variant\u003c\/strong\u003e: FEPL-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eABB Manufacturing Code\u003c\/strong\u003e: 3ABD0000072120\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternate Order Code\u003c\/strong\u003e: 3AUA0000072120\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Drive Platforms\u003c\/strong\u003e: ACS355, ACS580, ACS880, ACS380\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Interface\u003c\/strong\u003e: Dual RJ-45 socket configuration (2 ports)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDrive Interface Physical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFEPL-02 (3ABD0000072120)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e6.0 cm x 13.0 cm x 8.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupply 5 VDC +\/-5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eEthernet POWERLINK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Speed\u003c\/td\u003e\n\u003ctd\u003e100 Mbit\/s full-duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 % RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eNetwork Determinism \u0026amp; Firmware Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly to the drive main control board via the internal option slot, routing real-time motion references and status words across deterministic networks. Backplane bus communication velocity licences and Profinet \/ EtherNet\/IP \/ POWERLINK deterministic integration ensure minimal latency jitter during dynamic velocity profiling. Hardware-level firmware flash compatibility ensures synchronized cyclic exchange without affecting drive internal execution loops.\u003c\/p\u003e\n\u003ch3\u003eLogistics \u0026amp; Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB FEPL-02 Ethernet POWERLINK adapter module (3ABD0000072120)\u003c\/li\u003e\n\u003cli\u003e1 x Grounding screw and mechanical mounting accessories\u003c\/li\u003e\n\u003cli\u003e1 x Technical installation instruction sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Assembly \u0026amp; Cabling Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption Slot Engagement\u003c\/strong\u003e: Ensure the variable frequency drive power source is completely disconnected and internal DC bus capacitors are discharged prior to mounting into the VFD option card slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding\u003c\/strong\u003e: Secure the card retention screw firmly to ensure low-impedance grounding between the adapter frame and the drive chassis ground reference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Selection\u003c\/strong\u003e: Employ Category 5e or better STP (Shielded Twisted Pair) cables with metallic RJ-45 connector shells to prevent EMI-induced frame corruption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTopology Wiring\u003c\/strong\u003e: Route dual Ethernet cables along direct line-of-sight trays away from high-voltage motor output leads to minimize signal noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Engineering FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow is electrical power supplied to the adapter card?\u003c\/p\u003e\n\u003cp\u003ePower is drawn directly from the host VFD internal control board backplane via the slot connection, operating on 5 VDC +\/-5 %.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical port layout is available for network daisy-chaining?\u003c\/p\u003e\n\u003cp\u003eThe module provides two RJ-45 connectors operating at 100 Mbit\/s full-duplex, allowing direct pass-through line topology without an external switch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat degree of galvanic isolation is provided between ports and drive control?\u003c\/p\u003e\n\u003cp\u003eThe network interface maintains an internal galvanic isolation rating of 500 VDC between network nodes and host drive circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the allowed operating temperature limits inside the VFD enclosure?\u003c\/p\u003e\n\u003cp\u003eThe card functions reliably within ambient enclosure operating temperatures ranging from 0 to +50 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the adapter module be installed while the VFD is powered?\u003c\/p\u003e\n\u003cp\u003eHot-plugging is strictly prohibited; all control board auxiliary power and high-voltage supply lines must be isolated prior to physical insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are network diagnostic states visually identified on the card?\u003c\/p\u003e\n\u003cp\u003eIntegrated LED indicators mounted on the front panel display real-time network link activity, bus communication status, and module fault conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat drive series are natively supported by this option module?\u003c\/p\u003e\n\u003cp\u003eThis adapter module is engineered for installation across ABB ACS355, ACS580, ACS880, and ACS380 variable frequency drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat precautions must be taken regarding cable shield termination?\u003c\/p\u003e\n\u003cp\u003eCables must utilize shielded RJ-45 terminations where the outer metallic braid connects directly to the RJ-45 jack shell for high-frequency noise grounding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021038178477,"sku":"3ABD0000072120","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/fepl-02_1.jpg?v=1791955345","url":"https:\/\/www.maxwellplc.com\/ga\/products\/fepl-02-3abd0000072120-abb-acs-drives-ethernet-powerlink-adapter-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}