{"product_id":"e5cc-rx2asm-006-omron-digital-temperature-controller-e5cc-series","title":"E5CC-RX2ASM-006 Omron Digital Temperature Controller E5CC Series","description":"\u003cp\u003eThe \u003cb\u003eOmron E5CC-RX2ASM-006\u003c\/b\u003e, also cataloged as the \u003cb\u003eE5CC\u003c\/b\u003e Digital Temperature Controller, operates as a dedicated hardware component for closed-loop thermal processing and relay output regulation within industrial control panels.\u003c\/p\u003e\n\u003ch3\u003ePart Number Structure \u0026amp; Suffix Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eE5CC\u003c\/b\u003e: Omron 48 mm x 48 mm DIN panel-mount temperature controller platform.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eR\u003c\/b\u003e: Primary control output 1 configured for SPST-NO relay output (250 VAC, 3 A resistive load).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eX\u003c\/b\u003e: Control output 2 not populated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e2\u003c\/b\u003e: Auxiliary output complement providing 2 independent relay alarm contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eA\u003c\/b\u003e: Power supply voltage rating accepting 100 to 240 VAC at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eS\u003c\/b\u003e: Connection interface utilizing standard rear M3 screw terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eM\u003c\/b\u003e: Universal process input accepting thermocouples, RTDs, and linear DC voltage\/current signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e006\u003c\/b\u003e: Option card module adding 2 digital event inputs and 1 analog transfer output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Physical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE5CC-RX2ASM-006\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.12 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.8 cm x 6.0 cm x 4.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.6 VA max at 100 to 240 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 to 240 VAC (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Signal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUniversal input (Thermocouple, Pt100 RTD, 4-20 mA, 0-10 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Output 1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSPST-NO Relay (250 VAC, 3 A resistive load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAuxiliary Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Relay outputs (250 VAC, 2 A resistive load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOption Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Event inputs and 1 analog transfer output (4-20 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEmbedded System Memory \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe high-speed control core executes 50 ms sampling cycles across the universal sensor front-end. Internal system memory preserves firmware flash compatibility across setting parameters, writing user scaling factors, PID constants, and limit values to non-volatile EEPROM without battery backup. Onboard boot routines verify flash memory integrity during initial power-up sequences, preventing relay output latching until internal DC voltage rails reach nominal operational limits.\u003c\/p\u003e\n\u003ch3\u003eStandard Shipment Deliverables\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Omron E5CC-RX2ASM-006 Temperature Controller Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Panel Mounting Adapter Bracket\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Waterproof Sealing Rubber Gasket\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePanel Mounting Directives \u0026amp; Wiring Setup\u003c\/h3\u003e\n\u003ch4\u003ePanel Door Preparation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCut a 45 mm x 45 mm square opening in the enclosure door; fit the rubber gasket over the front housing bezel to maintain IP66 front-panel water and dust protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsert the controller from the front of the cutout and slide the rear adapter clamp forward until it locks tight against the interior panel door.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTerminal Wiring Procedures\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSecure field conductors to the rear M3 screw terminals using crimped ring or fork terminals; torque terminal screws to 0.5 N-m.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate sensor input leads and transfer output lines from AC line power and VFD motor cables in grounded metallic conduit to prevent electrical noise coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat sensor types are accepted by the universal input terminal?\u003c\/p\u003e\n\u003cp\u003eThe universal input accepts standard thermocouples (K, J, T, E, R, S, B), Pt100\/JPt100 RTDs, and linear DC current\/voltage signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat load current can the primary relay control output switch?\u003c\/p\u003e\n\u003cp\u003eThe primary relay output (Control Output 1) switches up to 250 VAC at 3 A under purely resistive load conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat capabilities are provided by the 006 option designation?\u003c\/p\u003e\n\u003cp\u003eOption code 006 incorporates 2 digital event inputs for external setpoint selection or run\/stop switching, plus 1 analog transfer output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are control parameters preserved during an AC power failure?\u003c\/p\u003e\n\u003cp\u003eInternal EEPROM non-volatile memory retains all PID parameters, alarm setpoints, and input configuration settings without battery backup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the sampling cycle time of the controller input circuit?\u003c\/p\u003e\n\u003cp\u003eThe analog front-end samples thermocouple, RTD, or process input signals at a 50 ms update cycle rate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat panel cutout size is required for mounting the unit?\u003c\/p\u003e\n\u003cp\u003eThe instrument fits into a standard DIN 45 mm x 45 mm square panel cutout with a front bezel footprint of 48 mm x 48 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is environmental front-panel sealing maintained?\u003c\/p\u003e\n\u003cp\u003eInstalling the unit with the supplied rubber sealing gasket provides an IP66 water-resistant and dust-tight front interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the auxiliary outputs be configured for alarm functions?\u003c\/p\u003e\n\u003cp\u003eYes, the 2 independent auxiliary relay outputs can be mapped to high\/low absolute or deviation alarm triggers via software settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306598088877,"sku":"E5CC-RX2ASM-006","price":148.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/E5CC-RX2ASM-006.jpg?v=1789997778","url":"https:\/\/www.maxwellplc.com\/ga\/products\/e5cc-rx2asm-006-omron-digital-temperature-controller-e5cc-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}