Product Overview
The DO810 (3BSE008510R1) Digital Output Module, also cataloged as the DO810 Digital Output Module, operates as a dedicated hardware component for signal processing or control execution within industrial automation architectures. This module is specifically engineered for the ABB S800 I/O system, providing 16 high-speed digital output channels for controlling field devices such as solenoids, contactors, and actuators. Each channel is designed to deliver a stable 10–30 V DC output signal with integrated protective circuitry. The module architecture enables integration into distributed control systems, allowing for granular control of discrete process variables while maintaining electrical isolation between channel groups.
Technical Specifications
| Parameter | Specification |
| Model | DO810 (3BSE008510R1) |
| Brand | ABB |
| Origin | Sweden |
| Weight | 0.16 kg |
| Dimensions | 4.5 x 11 x 0.15 cm |
| Operating Temperature | Industrial Standard |
| Power Consumption | 24 V DC (Bus Powered) |
| Channels | 16 (Two groups of eight) |
| Signal Parameters | 10–30 V DC, 0.5 A max per channel |
Brand-Specific Technical Block
The DO810 utilizes the ABB S800 I/O backplane communication bus to facilitate deterministic data transfer between the module and the host controller. The design features high I/O density by grouping sixteen channels into two electrically isolated eight-channel segments. Communication is managed through the ModuleBus protocol, which ensures real-time diagnostic reporting of short-circuit, overvoltage, and thermal overload status to the engineering station. Firmware compatibility is maintained through the system configuration software, ensuring that the module accurately maps output states from the controller application logic to the physical field terminals.
Ordering Information
-
Included items: DO810 Digital Output Module, MTU (Module Termination Unit) interface connector.
-
Standard package: Industrial electrostatic protective packaging.
-
Optional accessories: Spare field terminal blocks, cable trunking markers, redundant module housing kits.
Installation Guidelines
-
Install the DO810 module onto an appropriate S800 I/O MTU (Module Termination Unit), ensuring the mechanical locking pins are fully seated.
-
Ground the system MTU rail to the cabinet common earth to provide a low-impedance path for EMI suppression.
-
Utilize shielded cabling for all field output wiring if the cable runs exceed typical local branch requirements to minimize electrical noise coupling.
-
Ensure output wiring current does not exceed 0.5 A per channel to prevent tripping the internal thermal overload protection.
-
Observe physical clearance requirements between the output module and high-power inverter or drive cabling within the control cabinet.
-
Verify that the ModuleBus connection is intact before applying 24 V DC auxiliary power to the MTU.
Frequently Asked Questions
Q: Does the DO810 support hot-swap behavior?
A: Yes, the module supports hot-swapping within an S800 I/O system; the module can be replaced during operation without removing power from the backplane.
Q: How does the module affect backplane load?
A: The DO810 draws a specific current from the ModuleBus; verify the total power budget of the S800 rack before adding additional modules.
Q: Is there a redundancy switching delay?
A: Redundancy switching for the DO810 is managed by the host system controller logic; delay is defined by the system scan cycle and failover configuration.
Q: Is firmware compatibility required?
A: Yes, the module must be compatible with the system’s current I/O configuration and controller firmware revision for proper diagnostic reporting.
Q: Does the unit provide signal isolation?
A: The module features electrical isolation between the two channel groups (eight channels each) and the ModuleBus interface.
Q: What are the field wiring constraints?
A: Wiring must be rated for the expected output current and voltage; avoid exceeding the maximum thermal limit of the terminal blocks.
Q: Can the module detect open-load conditions?
A: The diagnostic features primarily focus on short-circuit and overvoltage; open-load detection depends on the specific host system configuration.
Q: How is the fault signaled?
A: Faults are signaled via the ModuleBus to the controller, and the local channel LED will indicate an error state for quick troubleshooting.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.