{"product_id":"di86-32-57275782d-abb-stromberg-stromberg-digital-input-board","title":"DI86-32 57275782D ABB Stromberg Stromberg Digital Input Board","description":"\u003cp\u003eConfigured for discrete signal monitoring in industrial control platforms, the \u003cstrong\u003eABB Stromberg DI86-32 57275782D\u003c\/strong\u003e (\u003cstrong\u003eDI86-32\u003c\/strong\u003e Digital Input Board) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown \u0026amp; Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase Model Designation: DI86-32\u003c\/li\u003e\n\u003cli\u003eFactory Part Number: 57275782D\u003c\/li\u003e\n\u003cli\u003eHardware Classification: Digital Input Board\u003c\/li\u003e\n\u003cli\u003eSeries Architecture: ABB Stromberg Control Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDI86-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB Stromberg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e57275782D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eVerify via Factory Label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.8 x 18.5 x 26 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard internal rack supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Function\u003c\/td\u003e\n\u003ctd\u003eMulti-channel discrete signal acquisition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Board configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication and I\/O Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module communicates via system backplane bus structures, supporting reliable data transfer velocity across control node architectures. Firmware flash compatibility ensures proper integration with system CPU revision levels. I\/O density scaling allows efficient channel allocation for discrete sensors, while internal bus protocols manage deterministic state updates without data packet collisions.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x DI86-32 Digital Input Board Module\u003c\/li\u003e\n\u003cli\u003e1 x Factory Compliance Document\u003c\/li\u003e\n\u003cli\u003e1 x ESD Protection Packaging Envelope\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation and Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSlot Insertion: Slide the printed circuit board smoothly into the designated rack slot, ensuring edge connectors align precisely with backplane sockets.\u003c\/li\u003e\n\u003cli\u003eFastener Security: Tighten all integrated retaining screws evenly to maintain mechanical stability and secure ground contact.\u003c\/li\u003e\n\u003cli\u003eSignal Shielding: Route field wiring away from high-voltage power cables and terminate signal shields to the cabinet ground bar.\u003c\/li\u003e\n\u003cli\u003eVentilation Control: Ensure adequate vertical spacing within the enclosure to support natural thermal convection across the module surface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this digital input board support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eNo, removing or inserting the board while the rack is powered can cause bus communication faults or damage internal components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of signals does this board process?\u003c\/p\u003e\n\u003cp\u003eThe module processes discrete binary state signals from industrial sensors, switches, and contact closures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are input channels protected against electrical noise?\u003c\/p\u003e\n\u003cp\u003eInternal optical isolation and filtering components safeguard the circuitry against standard industrial electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre firmware updates required for installation?\u003c\/p\u003e\n\u003cp\u003eFirmware updates are generally unnecessary unless upgrading the main rack control processor architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat causes intermittent input state readings?\u003c\/p\u003e\n\u003cp\u003eLoose field wiring terminals, degraded cable shielding, or poor backplane seating typically cause erratic signal states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs external power supply required for the inputs?\u003c\/p\u003e\n\u003cp\u003eField sensors require an appropriate external DC power loop depending on the specific application wiring configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat tool is recommended for terminal connections?\u003c\/p\u003e\n\u003cp\u003eA calibrated precision screwdriver should be used to secure terminal fasteners without stripping threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is hardware operational status verified?\u003c\/p\u003e\n\u003cp\u003eFront-panel diagnostic light-emitting diodes indicate power status and active channel state conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021149196461,"sku":"DI86-32","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/DI86-32_13.jpg?v=1784612274","url":"https:\/\/www.maxwellplc.com\/ga\/products\/di86-32-57275782d-abb-stromberg-stromberg-digital-input-board","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}