{"product_id":"cp1w-ts002-omron-cp1w-temperature-sensor-unit","title":"CP1W-TS002 OMRON CP1W Temperature Sensor Unit","description":"\u003cp\u003eThe \u003cstrong\u003eOMRON CP1W-TS002\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP1W\u003c\/strong\u003e Temperature Sensor Unit, provides four thermocouple input channels for temperature measurement in OMRON CP-series PLC systems. It accepts either J-type or K-type thermocouples, with the selected thermocouple type applied consistently across all inputs. Temperature conversion data is transferred as 16-bit binary values.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eOMRON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP1W-TS002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eCP1W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTemperature Sensor Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Classification\u003c\/td\u003e\n\u003ctd\u003eAnalog I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eCP1W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003eThermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Thermocouples\u003c\/td\u003e\n\u003ctd\u003eJ, K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllocated Input Words\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eAll channels use the same selected thermocouple type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e250 ms for 2 or 4 input points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverted Data\u003c\/td\u003e\n\u003ctd\u003e16-bit binary data, 4-digit hexadecimal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003ePhotocouplers between all temperature input signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP1W-TS002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOMRON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e250 g unpacked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e9.0 cm x 8.6 cm x 5.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 11.0 cm x 14.3 cm x 12.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC: 40 mA max.; 24 VDC: 59 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Sensor\u003c\/td\u003e\n\u003ctd\u003eThermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Types\u003c\/td\u003e\n\u003ctd\u003eJ or K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resolution\u003c\/td\u003e\n\u003ctd\u003e12 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllocated Input Words\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e250 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverted Temperature Data\u003c\/td\u003e\n\u003ctd\u003e16-bit binary data, 4-digit hexadecimal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation\u003c\/td\u003e\n\u003ctd\u003ePhotocouplers between all temperature input signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOMRON PLC Temperature Input Architecture\u003c\/h3\u003e\n\u003cp\u003eThe CP1W-TS002 is an expansion temperature sensor unit for OMRON CP-series PLC architectures. Its four thermocouple channels occupy four input words, allowing each temperature measurement to be represented in the CPU input area as converted binary data. The module supports J-type or K-type thermocouples, but all connected channels must use the same selected thermocouple type.\u003c\/p\u003e\n\u003cp\u003eThe temperature conversion process uses a 250 ms conversion time for two or four active input points. Photocoupler isolation is provided between the temperature input signals. This electrical separation should be considered when wiring thermocouple circuits and establishing the control-panel grounding arrangement.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x OMRON CP1W-TS002 Temperature Sensor Unit\u003c\/li\u003e\n\u003cli\u003e1x Factory terminal\/interface assembly as supplied with the unit\u003c\/li\u003e\n\u003cli\u003eModel identification: CP1W-TS002\u003c\/li\u003e\n\u003cli\u003eCompatible sensor category: J-type or K-type thermocouple\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the CP1W-TS002 as an expansion unit within the supported OMRON CP-series PLC configuration.\u003c\/li\u003e\n\u003cli\u003eConfigure all four temperature inputs for the same thermocouple type, either J or K.\u003c\/li\u003e\n\u003cli\u003eDo not mix J-type and K-type thermocouples on the same CP1W-TS002 configuration.\u003c\/li\u003e\n\u003cli\u003eKeep thermocouple wiring separated from high-voltage power conductors, motor cables, and high-current switching circuits.\u003c\/li\u003e\n\u003cli\u003eUse thermocouple extension or compensating cable appropriate to the selected thermocouple type.\u003c\/li\u003e\n\u003cli\u003eMaintain correct thermocouple polarity throughout the sensor circuit.\u003c\/li\u003e\n\u003cli\u003eAvoid unnecessary junctions between thermocouple conductors and ordinary copper wiring.\u003c\/li\u003e\n\u003cli\u003eRoute temperature input wiring with appropriate shielding where the installation is exposed to electrical noise.\u003c\/li\u003e\n\u003cli\u003eConnect panel grounding according to the PLC system installation requirements rather than creating independent uncontrolled ground paths.\u003c\/li\u003e\n\u003cli\u003eVerify the configured thermocouple type and channel allocation before applying the converted temperature values in the PLC program.\u003c\/li\u003e\n\u003cli\u003eConfirm that the available CPU input-word allocation matches the four words required by the module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan CP1W-TS002 accept both J-type and K-type thermocouples simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The module is switchable between J and K thermocouple operation, but the same thermocouple type must be used for all inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many thermocouple inputs does CP1W-TS002 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCP1W-TS002 provides 4 thermocouple input channels. The module allocates 4 input words for the converted temperature data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the temperature conversion time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe specified conversion time is 250 ms for 2 or 4 input points. The converted temperature values are transferred as 16-bit binary data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat data format is produced by the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTemperature data is converted into 16-bit binary data represented as 4-digit hexadecimal values for processing within the PLC input area.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs isolation provided between temperature input signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Photocouplers are provided between all temperature input signals, providing electrical separation between the temperature input circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the power consumption requirements?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaximum current consumption is 40 mA at 5 VDC and 59 mA at 24 VDC. These values should be included when calculating the expansion-unit power load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the physical dimensions of CP1W-TS002?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unpacked module measures 9.0 cm x 8.6 cm x 5.0 cm. The specified unpacked weight is 250 g.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module provide analog voltage or current inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. CP1W-TS002 is specifically a thermocouple temperature sensor unit. Its four inputs are intended for J-type or K-type thermocouple signals rather than standard voltage or current inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306642784429,"sku":"CP1W-TS002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CP1W-TS002_1.jpg?v=1788839878","url":"https:\/\/www.maxwellplc.com\/ga\/products\/cp1w-ts002-omron-cp1w-temperature-sensor-unit","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}