{"product_id":"cp1l-m30dt-d-omron-cp1l-series-cpu-unit","title":"CP1L-M30DT-D Omron CP1L Series CPU Unit","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CP1L-M30DT-D\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP1L\u003c\/strong\u003e High Performing Programmable Controller, operates as a dedicated hardware component for high-speed cyclic execution and embedded Ethernet comms within CP1L automation networks.\u003c\/p\u003e\n\u003ch3\u003eNomenclature \u0026amp; Option Decoding\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCP1L\u003c\/strong\u003e: Base designation for compact high-functionality programmable controller series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM\u003c\/strong\u003e: Medium-scale memory CPU unit supporting expansion options and up to 3 extension modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30\u003c\/strong\u003e: Total integrated I\/O point capacity (18 inputs, 12 outputs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD\u003c\/strong\u003e: 24 VDC input circuit configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eT\u003c\/strong\u003e: Transistor sinking output driver layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD\u003c\/strong\u003e: 24 VDC external system power supply input requirement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Operating Limits\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP1L-M30DT-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e16.0 cm x 11.0 cm x 10.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e20 W max at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory\u003c\/td\u003e\n\u003ctd\u003e10K steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTask Capability\u003c\/td\u003e\n\u003ctd\u003e288 tasks (32 cyclic tasks, 256 interrupt tasks)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard Analog Input\u003c\/td\u003e\n\u003ctd\u003e1 non-isolated channel (0 to 10 V range, 1\/256 resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Unit Limit\u003c\/td\u003e\n\u003ctd\u003e3 CP-series expansion or expansion I\/O units max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBus Velocity \u0026amp; Network Determinism\u003c\/h3\u003e\n\u003cp\u003eThe processing subsystem optimizes backplane bus communication velocity across connected I\/O extension racks, maintaining deterministic networks execution even during heavy interrupt cycles. Internal memory allocation guarantees firmware flash compatibility and predictable I\/O density scaling throughout complex ladder and structured text routine loops.\u003c\/p\u003e\n\u003ch3\u003eScope of Delivery\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron CP1L-M30DT-D PLC CPU Controller\u003c\/li\u003e\n\u003cli\u003e1 x Detachable Terminal Block Protection Cover\u003c\/li\u003e\n\u003cli\u003e1 x Quick Installation Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnclosure Mounting \u0026amp; Wiring Practices\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Attachment\u003c\/strong\u003e: Mount the chassis directly onto a 35 mm DIN rail. Ensure a minimum vertical space of 20 mm above and below the housing to facilitate thermal convection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 VDC Line Connection\u003c\/strong\u003e: Terminate incoming 24 VDC operating power to the marked supply terminals. Run dedicated ground wiring to the PE lug using short, low-impedance conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Signal Isolation\u003c\/strong\u003e: Separate low-level input\/output signal cables from 230 VAC power leads and motor drive cables to eliminate inductive coupling disturbances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the system behave when switching from RUN mode to PROGRAM mode?\u003c\/p\u003e\n\u003cp\u003eTransistor outputs turn off immediately upon mode transition, while internal memory holding bits maintain their last logic state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat language formats are supported within function block structures?\u003c\/p\u003e\n\u003cp\u003eFunction block instances allow programming via standard ladder diagrams or structured text (ST) defined within CX-Programmer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the response latency for the high-speed interrupt inputs?\u003c\/p\u003e\n\u003cp\u003eThe 6 onboard interrupt inputs deliver a standard response time of 0.3 ms and support pulse frequency processing up to 5 kHz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan CP-series expansion units be connected or removed while energized?\u003c\/p\u003e\n\u003cp\u003eNo, attaching or detaching expansion modules under hot-power conditions risks permanent circuit board and backplane damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are sinking transistor outputs wired to the external load circuit?\u003c\/p\u003e\n\u003cp\u003eSinking transistor channels switch the negative (0 VDC) side of the connected load, requiring positive DC potential on the load side.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat memory component retains real-time clock data during main power outage?\u003c\/p\u003e\n\u003cp\u003eAn optional CP1W-BAT01 lithium battery maintains internal clock counters and non-volatile work bit areas when unpowered.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat steps verify proper terminal block wiring connection tightness?\u003c\/p\u003e\n\u003cp\u003eApply a torque wrench to terminal screws to ensure tightening force remains within the manufacturer specification of 0.5 N m.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow can an backplane communication fault LED error be cleared?\u003c\/p\u003e\n\u003cp\u003eInspect expansion ribbon bus latch connections, remove foreign debris from edge pins, and cycle the main 24 VDC supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306627940525,"sku":"CP1L-M30DT-D","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CP1L-M30DT-D_2.jpg?v=1788589998","url":"https:\/\/www.maxwellplc.com\/ga\/products\/cp1l-m30dt-d-omron-cp1l-series-cpu-unit","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}