{"product_id":"cj2m-cpu34-omron-built-in-ethernet-ip-cpu-units-cj2m-series","title":"CJ2M-CPU34 Omron Built-in EtherNet\/IP CPU Units CJ2M Series","description":"\u003cp\u003eConfigured for high-speed sequence processing and cyclic data exchange over industrial Ethernet in Omron automation architectures, the \u003cb\u003eOmron CJ2M-CPU34\u003c\/b\u003e (\u003cb\u003eCJ2M-CPU34\u003c\/b\u003e Built-in EtherNet\/IP CPU Unit) provides direct physical execution of control logic and network frame processing.\u003c\/p\u003e\n\u003ch3\u003eHardware Nomenclature \u0026amp; Model Architecture\u003c\/h3\u003e\n\u003cp\u003eThe part number structure denotes specific physical and operational capabilities within the CJ2-series controller family:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCJ2M\u003c\/b\u003e: Base controller series platform supporting modular I\/O expansion racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCPU3\u003c\/b\u003e: CPU architecture variant featuring built-in EtherNet\/IP socket connectivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e4\u003c\/b\u003e: System memory tier designating 30K steps of logic execution capacity and extended data memory banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering \u0026amp; Performance Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCJ2M-CPU34\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.19 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 cm x 7.5 cm x 6.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.5 cm x 14.0 cm x 11.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.70 A at 5 VDC (Backplane internal bus supply)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProgram Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30K steps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Memory Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e160K words (DM: 32K words, EM: 32K words x 4 banks)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExecution Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.04 us (Basic LD instruction)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum I\/O Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2560 points \/ 40 Units (Maximum 3 expansion racks)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Communications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEtherNet\/IP port (100Base-TX), USB 2.0 port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Network \u0026amp; Bus Architecture\u003c\/h3\u003e\n\u003cp\u003eThe CPU unit integrates dedicated hardware logic for managing EtherNet\/IP deterministic network traffic alongside backplane bus communication velocity. Internal dual-processor routing isolates execution of user ladder code from implicit CIP message parsing, maintaining consistent scan times during heavy network broadcast activity. Firmware flash compatibility allows field update of protocol stacks while preserving allocated data memory memory banks (EM\/DM) in non-volatile storage.\u003c\/p\u003e\n\u003ch3\u003ePackaging \u0026amp; Ordering Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Omron CJ2M-CPU34 CPU Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 x Terminal block protective dust covers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Hardware installation and instruction sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation \u0026amp; Wiring Procedures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDIN-Rail Mounting\u003c\/b\u003e: Secure unit on 35 mm DIN rail. Ensure end plates are installed on both extremities of the bus assembly to prevent lateral movement and backplane pin damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eGrounding Requirements\u003c\/b\u003e: Connect functional ground (FG) terminal directly to a dedicated earth ground using a wire with a cross-sectional area of at least 2 mm sq. Keep lead lengths under 20 meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePower Supply Wiring\u003c\/b\u003e: Verify backplane current load does not exceed power supply output rating. Do not route 230 VAC power lines in the same conduit as 24 VDC I\/O lines or EtherNet\/IP communication cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCable Shielding\u003c\/b\u003e: Utilize Category 5e or higher double-shielded STP cables for EtherNet\/IP connections to prevent electromagnetic noise coupling into the RJ45 physical layer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the CPU unit support hot-swapping during active backplane operation?\u003c\/p\u003e\n\u003cp\u003eNo, power to the rack power supply unit must be turned off before inserting or removing the CPU unit or connected expansion I\/O modules to prevent hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the current draw on the 5 VDC internal backplane bus?\u003c\/p\u003e\n\u003cp\u003eThe CJ2M-CPU34 draws 0.70 A from the internal 5 VDC bus supplied by the rack power supply unit. System designers must include this in total power calculations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are the extended memory banks accessed within user memory?\u003c\/p\u003e\n\u003cp\u003eExtended Data Memory (EM) consists of 4 banks of 32K words each. Bank switching is performed via instruction execution or explicit addressing within user logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the built-in EtherNet\/IP port handle both CIP messaging and socket communications?\u003c\/p\u003e\n\u003cp\u003eYes, the port supports simultaneous implicit tag data links, explicit CIP messaging, and standard TCP\/IP socket communications over standard Ethernet infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat action is required if the system battery voltage drops below operational limits?\u003c\/p\u003e\n\u003cp\u003eThe ERR\/ALM indicator will flash. Replace the battery with an approved Omron unit within five days while the system is powered to retain volatile RAM data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cable spec is required for USB programming communication?\u003c\/p\u003e\n\u003cp\u003eUse a standard USB 2.0 compliant A-to-B cable, maximum 5 meters long, connected directly to the front panel USB connector for CX-Programmer configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat limits exist on rack expansion for this specific processor model?\u003c\/p\u003e\n\u003cp\u003eThe CPU supports up to 40 modules distributed across a maximum of 3 expansion racks connected via standard CJ-series expansion cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit process basic ladder instructions during program scan?\u003c\/p\u003e\n\u003cp\u003eThe hardware execution engine processes basic LD instructions at 0.04 microseconds per instruction, maintaining deterministic execution across the 30K step program block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306610966701,"sku":"CJ2M-CPU34","price":202.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_cj2m-cpu34_1.jpg?v=1788411840","url":"https:\/\/www.maxwellplc.com\/ga\/products\/cj2m-cpu34-omron-built-in-ethernet-ip-cpu-units-cj2m-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}