{"product_id":"ci873ak01-abb-ci873-3bse056899r1-ethernet-ip-devicenet-master-module-800xa-series","title":"CI873AK01 ABB CI873 3BSE056899R1 EtherNet IP DeviceNet Master Module 800xA Series","description":"\u003cp\u003eConfigured for EtherNet IP \/ DeviceNet communication tasks in System 800xA network environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB 3BSE056899R1\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCI873\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEtherNet IP \/ DeviceNet Master Module, provides direct physical\/electrical execution. It establishes deterministic master-level link interfaces via the CEX bus interface of the host controller, managing physical link signals, routing protocols, and cyclic data transfers across attached industrial field networks.\u003c\/p\u003e\n\u003ch3\u003eModule Variant and Article Number Mapping\u003c\/h3\u003e\n\u003cp\u003eThe base model designation and the specific commercial article numbers correspond to the factory hardware revisions listed below:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBase Model: CI873\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturing Article Number: 3BSE056899R1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlternative Order Reference: 3BSE092695R1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAssociated System Platform: 800xA Controller Series (including High Integrity \/ HI Controllers)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCI873\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Interface Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtocol Support\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEtherNet IP \/ DeviceNet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExecution Role\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaster\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTransmission Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10\/100 Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLine Redundancy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Redundancy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHot Swap Capability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eController Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHI (High Integrity) Controller \/ Standard Controllers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Units on CEX Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRJ-45 female (8-pin) connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003etyp 160 mA at 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 deg C (+32 to +131 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +70 deg C (-40 to +158 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 2000 m (per IEC\/EN 61131-2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePollution Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDegree 2 (per IEC\/EN 61131-2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCorrosion Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 compliant to ISA 71.04\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 95 %, non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Class\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 (according to EN60529, IEC 529)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Safety Labels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL 61010-1, UL 61010-2-201, CE-marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHazardous Location\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL 60079-15, cULus Class 1 Zone 2, AEx nA IIC T4, ExnA IIC T4Gc X\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMarine Certifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDNV-GL (Pending: ABS, BV, LR)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompliance Regulations\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEU RoHS, UAE RoHS, CN RoHS, WEEE (DIRECTIVE\/2012\/19\/EU)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e59 mm x 185 mm x 127.5 mm (2.3 in x 7.3 in x 5.0 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight (including base)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e700 g (1.5 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Network Optimization and Deterministic Velocity\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates dedicated hardware execution for EtherNet\/IP deterministic networks, bypassing traditional software-layer bottlenecks on the backplane bus communication velocity licenses. This design ensures stable I\/O density scaling during multi-node periodic data exchange. Firmware flash compatibility protocols embedded in the module protect against timing jitter during parallel master execution on the CEX bus, stabilizing high-speed industrial control performance when deployed alongside high-integrity safety loops.\u003c\/p\u003e\n\u003ch3\u003eLogistics Packaging Details\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x ABB CI873 3BSE056899R1 Communication Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Product Certification and Factory Test Slip\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x ESD Protective Shielding Bag\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Deployment and Grounding Protocol\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCEX Bus Physical Attachment\u003c\/p\u003e\n\u003cp\u003eMount the unit onto the standard CEX bus rail assembly. Secure the structural locking tabs to prevent unintended physical separation during high-vibration events.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielded Ethernet Cable Routing\u003c\/p\u003e\n\u003cp\u003eUtilize category 5e or higher shielded twisted pair (STP) cabling terminated with robust metal-shielded RJ-45 plugs. Route the data lines away from high-voltage AC power tracks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHazardous Area Wiring Controls\u003c\/p\u003e\n\u003cp\u003eWhen deployed in Class 1, Zone 2 environments, isolate all connection points until the local atmosphere is verified as completely non-hazardous.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this interface module support structural hot-swapping during active controller operation?\u003c\/p\u003e\n\u003cp\u003eYes, the hardware supports hot-swap execution, allowing the module to be removed or replaced without stopping the remaining active CEX bus communication units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the threshold limit for maximum module deployment on a single CEX bus string?\u003c\/p\u003e\n\u003cp\u003eThe system architecture restricts installation to a maximum limit of 12 communication interface units across the local CEX expansion bus layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this module be applied directly within High Integrity (HI) safety-related controller applications?\u003c\/p\u003e\n\u003cp\u003eYes, the unit is certified as safe for operational co-existence and functional use together with ABB High Integrity Controller systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical connector type is utilized for the primary network uplink interface?\u003c\/p\u003e\n\u003cp\u003eThe front-facing network panel contains one standard 8-pin RJ-45 female receptacle optimized for industrial Ethernet cabling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is line redundancy handled across the physical network medium for this model?\u003c\/p\u003e\n\u003cp\u003eThis specific hardware design provides no built-in line redundancy features; network fault tolerance must be achieved through module redundancy pairs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific structural environment limits apply to chemical gas protection?\u003c\/p\u003e\n\u003cp\u003eThe internal circuit board assemblies features a conformal coating that is G3 compliant to ISA 71.04 standards for harsh atmospheres.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the specific power supply requirements drawn directly from the host system?\u003c\/p\u003e\n\u003cp\u003eThe unit exhibits a typical internal current consumption profile of 160 mA measured at a nominal supply voltage of 24 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat steps must be followed to ensure compliance with cULus Class 1 Zone 2 hazardous certifications?\u003c\/p\u003e\n\u003cp\u003eThe module must be enclosed within an IP54 or better tool-secured cabinet structure to avoid mechanical impacts and prevent spark hazards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46860908953773,"sku":"3BSE056899R1","price":2999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CI873AK01_1.jpg?v=1784079956","url":"https:\/\/www.maxwellplc.com\/ga\/products\/ci873ak01-abb-ci873-3bse056899r1-ethernet-ip-devicenet-master-module-800xa-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}