{"product_id":"bently-nevada-990-05-xx-01-cn-vibration-transmitter","title":"Bently Nevada 990-05-XX-01-CN Vibration Transmitter","description":"\u003cp\u003eConfigured for mechanical vibration monitoring, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-05-XX-01-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e990-05-XX-01-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVibration Transmitter) provides direct electrical execution of vibration signal conditioning and 4-20 mA loop output generation for machinery diagnostic systems.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix \u0026amp; Configuration Overview\u003c\/h3\u003e\n\u003cp\u003eThe 990-05-XX-01-CN is a vibration transmitter calibrated for a 0-5 mils peak-to-peak (0-125 micrometer peak-to-peak) measurement range. The assembly features an integrated DIN rail mount design and carries environmental certifications including CSA Division 2, ATEX Zone 0, and ATEX Zone 2, with explicit ABS maritime approval for use in rigorous industrial conditions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e990-05-XX-01-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.46 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 x 7.3 x 5.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 to 35 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0-5 mils pp (0-125 micrometer pp)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLoop Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,000 Ohm (max) at 35 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Technical Attributes\u003c\/h3\u003e\n\u003cp\u003eThis transmitter utilizes eddy-current probe scaling to convert high-frequency proximity sensor signals into a standard 4-20 mA industrial process variable. Proper installation requires precise gap voltage validation, targeting -10 VDC at the probe interface to ensure linear transducer response. The transmitter internal circuitry maintains rotor dynamics signal integrity and incorporates protection mechanisms against signal noise, requiring careful grounding to minimize cross-talk suppression issues in dense instrumentation cabinets.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 990-05-XX-01-CN Vibration Transmitter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x DIN rail mounting clip set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical installation guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting:\u003c\/p\u003e\n\u003cp\u003eUtilize the integrated 35 mm DIN rail clips for mounting. Ensure the transmitter is oriented to allow adequate airflow for heat dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Connection:\u003c\/p\u003e\n\u003cp\u003eSupply between 12 and 35 VDC at the terminal block. Ensure total loop resistance, including cable, does not exceed 1,000 Ohm at 35 VDC to maintain signal accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProbe Interfacing:\u003c\/p\u003e\n\u003cp\u003eConnect to the proximity probe system using shielded cable. Validate that the probe gap voltage is within the specified linear range before finalizing transmitter calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental Protection:\u003c\/p\u003e\n\u003cp\u003eWhile the unit is ATEX\/CSA certified, ensure the final installation site conforms to the hazardous area classification markings indicated on the device label.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary function of this transmitter?\u003c\/p\u003e\n\u003cp\u003eThis device converts signals from proximity transducers into a proportional 4-20 mA current signal for integration into DCS or PLC monitoring platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this transmitter be used in hazardous locations?\u003c\/p\u003e\n\u003cp\u003eYes, it is certified for CSA Division 2, ATEX Zone 0, and ATEX Zone 2 applications. Always verify the installation site matches these safety ratings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum loop resistance?\u003c\/p\u003e\n\u003cp\u003eThe transmitter supports a maximum loop resistance of 1,000 Ohm when supplied with 35 VDC. Ensure cable resistance is calculated within this limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the input voltage range flexible?\u003c\/p\u003e\n\u003cp\u003eThe transmitter accepts a DC supply voltage between 12 and 35 VDC measured at the transmitter terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal output does this unit provide?\u003c\/p\u003e\n\u003cp\u003eThe unit provides a standard 4-20 mA current loop signal proportional to the measured peak-to-peak vibration level.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the vibration range defined?\u003c\/p\u003e\n\u003cp\u003eThis specific model is factory calibrated for a 0-5 mils peak-to-peak (or 0-125 micrometer peak-to-peak) measurement range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the unit include current limiting?\u003c\/p\u003e\n\u003cp\u003eYes, the transmitter internal circuitry provides current limiting, typically clamped at 23 mA to protect the loop and connected instrumentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this unit suitable for maritime applications?\u003c\/p\u003e\n\u003cp\u003eYes, the -CN suffix indicates that the transmitter includes ABS maritime approval for use in offshore and marine environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026854367405,"sku":"990-05-XX-01-CN","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-990-05-xx-03-cn-104m6732-01-vibration-transmitter-h5iy4frh0d5.jpg?v=1766979444","url":"https:\/\/www.maxwellplc.com\/ga\/products\/bently-nevada-990-05-xx-01-cn-vibration-transmitter","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}