{"product_id":"bently-nevada-330180-x1-cn-mod-145004-141-proximitor-sensor-3300-xl","title":"Bently Nevada 330180-X1-CN MOD:145004-141 Proximitor Sensor 3300 XL","description":"\u003cp\u003eConfigured for high-frequency signal conditioning in 3300 System platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330180-X1-CN MOD:145004-141\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330180-X1-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximitor Sensor) provides direct physical signal processing for vibration and position proximity probes. The sensor converts transducer inputs into linear voltage signals for monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePart Number: 330180-X1-CN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModification: 145004-141\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement Standard: 0 to 500 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSensitivity: 200 mV\/mil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply: -18 to -24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-X1-CN MOD:145004-141\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.8 x 3.5 x 7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-52 deg C to +100 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 mA (approx. at -24 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinearity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 1% of full scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and Transducer Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL Proximitor Sensor utilizes eddy-current principle-based sensing to track rotor dynamics. Precise probe scaling is required to ensure that the output voltage accurately represents the physical gap between the probe tip and the target surface. Field installation must include gap voltage validation to ensure the sensor operates within the target -10 VDC range. To ensure measurement integrity, shield termination must be consistent to provide cross-talk suppression in high-density rack environments, minimizing common-mode noise during low-amplitude vibration signal detection.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 330180-X1-CN Proximitor Sensor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Installation and technical data sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the sensor to a DIN-rail or bulkhead plate, ensuring the mounting surface provides an electrical ground connection to the sensor base.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect the coaxial cable from the proximity probe to the sensor input and ensure the connector is fully tightened to maintain environmental integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerify that the sensor is installed according to system grounding requirements to prevent ground loops that interfere with low-voltage signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApply -24 VDC power and measure the probe gap voltage with a digital multimeter to confirm calibration settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this sensor be used with non-standard extension cables?\u003c\/p\u003e\n\u003cp\u003eThe system is calibrated for specific cable lengths. Using non-standard lengths will result in measurement errors due to impedance mismatches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the response time of the 330180-X1-CN?\u003c\/p\u003e\n\u003cp\u003eThe sensor provides near-instantaneous output, with a frequency response ranging from 0 Hz to 10 kHz, suitable for standard monitoring requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the 4-20 mA output option configured?\u003c\/p\u003e\n\u003cp\u003eThe 4-20 mA output is an optional configuration; if equipped, ensure the loop impedance is within specified limits for the supply voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the sensor output short-circuit protected?\u003c\/p\u003e\n\u003cp\u003eYes, the output stage is designed to withstand a short-circuit condition without permanent damage to the internal circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I replace the sensor while the system is powered?\u003c\/p\u003e\n\u003cp\u003eWhile the electronics are robust, it is standard practice to isolate power before connecting or disconnecting sensor cables to avoid signal transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I identify the proper gap voltage?\u003c\/p\u003e\n\u003cp\u003eRefer to the specific sensor calibration curve; for standard 8 mm probes, the target is typically -10 VDC at the center of the linear range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the probe cable is damaged?\u003c\/p\u003e\n\u003cp\u003eDamage to the cable shield or core will cause signal noise or total loss of measurement, requiring immediate sensor or cable replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the sensor enclosure weatherproof?\u003c\/p\u003e\n\u003cp\u003eThe Proximitor housing is intended for indoor or protected enclosure use; it is not designed for direct exposure to high-pressure washdowns or extreme weather.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026777591981,"sku":"330180-X1-CN MOD:145004-141","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/330180-X1-CN3.jpg?v=1783412166","url":"https:\/\/www.maxwellplc.com\/ga\/products\/bently-nevada-330180-x1-cn-mod-145004-141-proximitor-sensor-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}