{"product_id":"bently-nevada-330180-x1-05-mod-145004-82-proximitor-sensors-3300-xl","title":"Bently Nevada 330180-X1-05 MOD 145004-82 Proximitor Sensors 3300 XL","description":"\u003cp\u003eConfigured for high-frequency signal conditioning in machinery protection architectures, the \u003cstrong\u003eBently Nevada 330180-X1-05 MOD 145004-82\u003c\/strong\u003e (\u003cstrong\u003e330180-X1-05 MOD 145004-82\u003c\/strong\u003e Proximitor Sensor) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown and Configuration Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase Model: 330180\u003c\/li\u003e\n\u003cli\u003eTotal Length and Mounting Option: X1 (Selectable system length options: 11 for 1.0 meter, 51 for 5.0 meters, 91 for 9.0 meters with DIN-mount)\u003c\/li\u003e\n\u003cli\u003eAgency Approval Option: 05 (CSA, ATEX, IECEx Approvals)\u003c\/li\u003e\n\u003cli\u003eModification Option: MOD 145004-82 (Custom factory hardware modification build)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05 MOD 145004-82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8.8 x 3.5 x 7.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e-17.5 VDC to -26 VDC loop powered (approx. 12 mA max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Function\u003c\/td\u003e\n\u003ctd\u003eRadio frequency signal demodulation and displacement voltage conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and Rotor Dynamics Architecture\u003c\/h3\u003e\n\u003cp\u003eEngineered for precision turbine surveillance, this proximitor unit drives eddy-current probe scaling by supplying radio frequency energy to the transducer tip and demodulating the return signal into a linear voltage output. Proper gap voltage validation is required during commissioning to lock the baseline output at -10 VDC, ensuring full linear dynamic range. Continuous signal filtering and internal shielding suppress ambient electromagnetic noise, protecting rotor dynamics analysis from cross-talk and phase distortion.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330180-X1-05 MOD 145004-82 Proximitor Sensor unit\u003c\/li\u003e\n\u003cli\u003e1 x DIN-mount locking clip assembly\u003c\/li\u003e\n\u003cli\u003e1 x Technical compliance documentation sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN-Rail Mounting: Secure the sensor housing firmly onto a standard 35 mm symmetrical DIN rail within a weather-resistant instrument enclosure.\u003c\/li\u003e\n\u003cli\u003eSignal Grounding: Terminate the coaxial shield exclusively at the monitoring system common earth to prevent damaging ground loop currents.\u003c\/li\u003e\n\u003cli\u003ePower Supply Regulation: Supply a regulated negative DC voltage ranging between -17.5 VDC and -26 VDC across the terminal blocks.\u003c\/li\u003e\n\u003cli\u003eInterchangeability Check: Verify that the total system length option matches the connected probe and extension cable lengths without requiring recalibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary electrical function of the 330180 proximitor sensor?\u003c\/p\u003e\n\u003cp\u003eIt generates radio frequency signals to drive the probe tip and converts the gap variation into a proportional voltage output for monitoring systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat power supply voltage range is required to operate this sensor?\u003c\/p\u003e\n\u003cp\u003eIt requires a negative DC input voltage between -17.5 VDC and -26 VDC delivered across its power input terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this proximitor model require manual bench calibration when replacing cables?\u003c\/p\u003e\n\u003cp\u003eNo, the 3300 XL system design guarantees complete interchangeability of components without altering system scaling or requiring recalibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the unit physically mounted inside an instrument cabinet?\u003c\/p\u003e\n\u003cp\u003eThe sensor features an integrated DIN-mount base designed for rapid installation onto standard 35 mm industrial DIN rails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat hazardous area certifications are included with the 05 approval option?\u003c\/p\u003e\n\u003cp\u003eThe sensor carries CSA, ATEX, and IECEx certifications for safe operation in explosive industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat causes an unstable or fluctuating gap voltage reading at the monitor?\u003c\/p\u003e\n\u003cp\u003ePoor shield grounding, damaged coaxial cables, loose terminal connections, or a scratched target surface can destabilize the voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is maintaining a nominal -10 VDC gap voltage critical during setup?\u003c\/p\u003e\n\u003cp\u003eIt ensures the probe operates directly in the center of its linear measurement range for accurate static and dynamic data collection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this sensor be used for both vibration and shaft position measurements?\u003c\/p\u003e\n\u003cp\u003eYes, it processes signals simultaneously to capture slow thermal position changes and high-frequency dynamic vibration waveforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026379428013,"sku":"330180-X1-05 145004-82","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/330180-x1-05-5.jpg?v=1783661569","url":"https:\/\/www.maxwellplc.com\/ga\/products\/bently-nevada-330180-x1-05-mod-145004-82-proximitor-sensors-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}