{"product_id":"bently-nevada-330105-02-12-05-02-05-3300-xl-series-proximity-probe","title":"Bently Nevada 330105-02-12-05-02-05 3300 XL Series Proximity Probe","description":"\u003cp\u003eConfigured for displacement sensing in rotating machinery protection networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330105-02-12-05-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330105-02-12-05-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical execution of eddy-current signal sensing.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330105: 3300 XL 8 mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Unthreaded length (20 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e12: Overall case length (120 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Total length (0.5 m)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Connector type (Miniature coaxial)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Agency approval (Multiple approvals)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330105-02-12-05-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.0 x 20.0 x 10.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to 177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Loop powered)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTarget Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 4140 Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eEddy-current probe scaling accuracy is required for the linearity of the vibration signal. Precise gap voltage validation at -10 VDC targets is necessary during commissioning to ensure the sensor response remains within the calibrated linear range. Cross-talk suppression must be enforced by maintaining proper physical separation between adjacent probes to prevent electromagnetic interference from the high-frequency oscillator. Rotor dynamics analysis depends on the stability of the signal path from the probe tip to the interface.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 unit 330105-02-12-05-02-05 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 set protective connector dust caps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 technical installation manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Install the probe into a rigid bracket to maintain a stable air gap during operation. Torque jam nuts to prevent mechanical shifting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Ensure electrical isolation between the probe housing and machine structure, unless system design dictates otherwise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Routing: Route coaxial cabling through dedicated metallic conduit, isolated from high-current power lines to minimize induced noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap Setting: Calibrate the air gap using a precision feeler gauge. Verify output voltage at the proximitor terminal confirms centering in the linear range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs this probe compatible with standard 3300 XL extension cables?\u003c\/p\u003e\n\u003cp\u003eYes, the 330105 probe is designed to integrate with 3300 XL extension cables, provided the system length remains consistent with the calibrated proximitor setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the standard target material?\u003c\/p\u003e\n\u003cp\u003eFactory calibration is optimized for AISI 4140 steel. Variations in target material magnetic properties require an adjustment to the sensitivity factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used in hazardous locations?\u003c\/p\u003e\n\u003cp\u003eThe 05 suffix indicates support for multiple agency approvals. Verify current certification markings against site-specific hazardous area requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum operating temperature?\u003c\/p\u003e\n\u003cp\u003eThe probe is rated for operation up to 177 deg C. Exceeding this temperature limit can damage internal coil potting and compromise measurement integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre the connector pins field-replaceable?\u003c\/p\u003e\n\u003cp\u003eNo, connectors are factory-swaged. Mechanical damage to the connector requires replacement of the entire probe and cable assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow can probe functionality be validated?\u003c\/p\u003e\n\u003cp\u003eMonitor gap voltage at the proximitor terminal. Signals outside the expected operating range indicate potential sensor or cable failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the probe tip require protection?\u003c\/p\u003e\n\u003cp\u003eThe tip is hardened, but not designed for physical contact with rotating targets. Maintain the specified air gap to prevent damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the probe require periodic maintenance?\u003c\/p\u003e\n\u003cp\u003eThe probe is a sealed solid-state component. Maintenance is limited to inspecting the cable integrity and connector cleanliness.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518809694381,"sku":"330105-02-12-05-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330105-02-12-05-02-05-proximity-switch-pvedaiaggai.jpg?v=1766979438","url":"https:\/\/www.maxwellplc.com\/ga\/products\/bently-nevada-330105-02-12-05-02-05-3300-xl-series-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}