{"product_id":"bently-nevada-330101-00-16-05-02-05-3300-xl-8-mm-proximity-probes","title":"Bently Nevada 330101-00-16-05-02-05 3300 XL 8 mm Proximity Probes","description":"\u003cp\u003eConfigured for high-precision vibration and position monitoring in 3300 System architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-00-16-05-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal transduction for rotating machinery. This 8 mm proximity probe utilizes eddy-current technology to output voltage signals proportional to the distance between the sensor tip and the conductive target surface.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown and Configuration Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePart Number: 330101-00-16-05-02-05\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProbe Type: 3300 XL 8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnthreaded Length: 00 - 0.0 in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCase Length: 16 - 1.6 in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTotal Length: 05 - 0.5 m (1.6 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector: 02 - Miniature coaxial ClickLoc connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAgency Approval: 05 - CSA, ATEX, IECEx Approvals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-16-05-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e58.5 x 1.5 x 1.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Transducer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and Transducer Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 330101 transducer relies on specific eddy-current probe scaling calibrated for AISI 4140 steel targets. Accurate rotor dynamics analysis requires rigorous gap voltage validation to ensure the signal maintains a -10 VDC target at the linear range center. Field deployment necessitates strict adherence to cross-talk suppression protocols, requiring a minimum of 1.5 inches (38 mm) separation between adjacent probe tips. Failure to maintain these spatial constraints can result in signal interference and measurement inaccuracies during high-frequency vibration data acquisition.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 330101 3300 XL 8 mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Threaded mounting nut\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the ClickLoc connector is properly mated and protected in environments where chemical or liquid exposure is possible.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Securing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTorque the 3\/8-24 UNF threads carefully to ensure stable probe positioning against vibrational forces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClearance Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eObserve the minimum side-view clearance of 1.5 inches (38 mm) from any metallic housing walls to prevent localized eddy-current interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerify probe compatibility with the system-specific extension cable and Proximitor sensor revision to ensure full interchangeability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is agency approval (CSA, ATEX, IECEx) specified for this model?\u003c\/p\u003e\n\u003cp\u003eThis model includes hazardous area certifications, allowing for installation in environments where explosive atmospheres may exist, provided appropriate safety barriers are used.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I shorten the probe cable in the field?\u003c\/p\u003e\n\u003cp\u003eNo. The 3300 XL system is a calibrated unit. Altering the cable length changes the impedance, which invalidates the calibration and degrades signal linearity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the linear range for this probe?\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL 8 mm system provides a linear range of 80 mils (2 mm), starting from an initial gap of approximately 10 mils.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe require shielding?\u003c\/p\u003e\n\u003cp\u003eThe probe is unarmored (3\/8-24 UNF thread, without armor). It should be installed within a protective conduit if exposed to mechanical damage or heavy debris.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the probe output signal measured?\u003c\/p\u003e\n\u003cp\u003eThe probe is a passive device; the output is measured as an AC signal processed by the connected Proximitor sensor, which translates gap changes to voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the gap voltage is not -10 VDC?\u003c\/p\u003e\n\u003cp\u003eA gap voltage outside the target range indicates the probe is either too close or too far from the shaft, potentially operating outside the linear measurement zone.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use this with any target material?\u003c\/p\u003e\n\u003cp\u003eFactory calibration is tuned for AISI 4140 steel. Other materials alter the electrical response; if used, the system requires non-standard field calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this probe compatible with previous 3300 series components?\u003c\/p\u003e\n\u003cp\u003eWhile the 3300 XL is an improvement, component interchangeability with older legacy 3300 systems is limited. Always verify the Proximitor sensor series for compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026629709997,"sku":"330101-00-16-05-02-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--2_56daa3ca-b6ec-49b1-a9c6-705e442277f7.jpg?v=1783584983","url":"https:\/\/www.maxwellplc.com\/ga\/products\/bently-nevada-330101-00-16-05-02-05-3300-xl-8-mm-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}