{"product_id":"bently-nevada-330101-00-10-10-02-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-10-10-02-00 3300 XL 8 mm Proximity Probe","description":"\u003cp\u003eConfigured for high-accuracy displacement and vibration transduction in 3300 System platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-00-10-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal conversion for rotating machinery analysis. This transducer captures both static position and dynamic vibration data from conductive target surfaces via eddy-current induction.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown and Configuration Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePart Number: 330101-00-10-10-02-00\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProbe Type: 3300 XL 8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnthreaded Length: 00 - 0.0 in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCase Length: 10 - 1.0 in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTotal Length: 10 - 1.0 m (3.3 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector: 02 - Miniature coaxial ClickLoc connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAgency Approval: 00 - Not required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-10-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e104 x 1.5 x 1.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Transducer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and Transducer Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 330101 transducer relies on precise eddy-current probe scaling to ensure linear voltage output relative to the target gap. During installation, technicians must perform gap voltage validation to target -10 VDC at the center of the linear operating range. Effective cross-talk suppression is achieved by maintaining specified spacing between adjacent probes, preventing interference within the eddy-field. Accurate rotor dynamics analysis depends on maintaining this signal integrity and avoiding the influence of external magnetic noise on the transducer’s high-frequency carrier signal.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 330101 3300 XL 8 mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Threaded mounting nut\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Surface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfirm the observed shaft material is AISI 4140 steel for factory-calibrated output accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProximity Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain a minimum side-view clearance of 1.5 inches (38 mm) from the probe tip to prevent signal distortion from mounting hole walls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProbe Separation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure a minimum of 1.5 inches (38 mm) between probe tips to suppress electromagnetic coupling and measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerify the ClickLoc connection is fully seated and the cable is protected from excessive bending to maintain characteristic impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used in hazardous locations?\u003c\/p\u003e\n\u003cp\u003eThis specific model (Agency Approval 00) is not rated for hazardous area use. Verify the installation environment requirements before deployment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of a non-standard cable length?\u003c\/p\u003e\n\u003cp\u003eThe probe and cable are a matched system. Changing the cable length alters the system impedance, which causes measurement errors and invalidates the factory calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the probe tip protected from fluid ingress?\u003c\/p\u003e\n\u003cp\u003eThe probe tip is sealed with high-performance synthetic materials. However, the connection point requires protection from direct exposure to chemical or process fluids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I repair a damaged probe cable?\u003c\/p\u003e\n\u003cp\u003eField repair of the coaxial cable is not recommended as it compromises the signal integrity and impedance matching of the transducer system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the linear range of this probe?\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL 8 mm system typically provides a linear range of 80 mils (2 mm), beginning at approximately 10 mils from the target surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the probe require external power?\u003c\/p\u003e\n\u003cp\u003eThe probe is a passive transducer. It receives power from the associated Proximitor sensor through the coaxial cable connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the probe held in place?\u003c\/p\u003e\n\u003cp\u003eThe probe is secured using the provided 3\/8-24 UNF threaded mounting nut, which should be torqued to ensure stable positioning during vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat defines the \"unthreaded length\"?\u003c\/p\u003e\n\u003cp\u003eThe unthreaded length is the portion of the probe case near the tip without threads, allowing for mounting configurations that require a smooth probe body.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026605887661,"sku":"330101-00-10-10-02-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--2_ef66c59a-0b2c-47b4-91b7-00d04600c50d.jpg?v=1783585237","url":"https:\/\/www.maxwellplc.com\/ga\/products\/bently-nevada-330101-00-10-10-02-00-3300-xl-8-mm-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}