{"product_id":"bently-nevada-130539-17-330400-330425-series-shielded-cable","title":"Bently Nevada 130539-17 330400 330425 Series Shielded Cable","description":"\u003cp\u003eConfigured for vibration signal transmission in Bently Nevada 330400 and 330425 Accelerometer systems, the \u003cstrong\u003eBently Nevada 130539-17\u003c\/strong\u003e (\u003cstrong\u003e130539-17\u003c\/strong\u003e 3-Conductor Shielded Cable) provides direct electrical connection between acceleration sensors and monitoring equipment through a shielded three-conductor assembly.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Details\u003c\/h3\u003e\n\u003cp\u003eThe 130539-17 is a dedicated cable assembly for Bently Nevada 330400 and 330425 accelerometers. The assembly includes a 3-socket plug with fluorosilicone elastomer boot at one end and terminal lugs at the opposite end.\u003c\/p\u003e\n\u003cp\u003eThe cable design uses 18 AWG (1.0 mm2) conductors with shielding for vibration measurement signal routing. The available cable length range is from 2.0 ft (0.6 m) to 99 ft (30 m).\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e130539-17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3-Conductor Shielded Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Series\u003c\/td\u003e\n\u003ctd\u003e330400 \/ 330425 Accelerometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003e3-conductor shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003e18 AWG (1.0 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector End\u003c\/td\u003e\n\u003ctd\u003e3-socket plug with fluorosilicone elastomer boot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination End\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharacteristic Impedance\u003c\/td\u003e\n\u003ctd\u003e50-100 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 100 pF\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length Range\u003c\/td\u003e\n\u003ctd\u003e2.0 ft (0.6 m) to 99 ft (30 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +200 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e110 x 1.5 x 1.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMachinery Vibration Signal Interface\u003c\/h3\u003e\n\u003cp\u003eThe 130539-17 cable assembly is configured for casing acceleration measurement circuits associated with Bently Nevada 330400 and 330425 accelerometers. The 330400 model provides a 50 g peak amplitude range with 100 mV\/g sensitivity, while the 330425 model provides a 75 g peak amplitude range with 25 mV\/g sensitivity.\u003c\/p\u003e\n\u003cp\u003eFor vibration monitoring applications, cable shielding helps maintain signal integrity by reducing electrical interference during transmission between the accelerometer and monitoring input interface.\u003c\/p\u003e\n\u003cp\u003eBently Nevada machinery monitoring systems require correct sensor wiring practices to preserve acceleration signal accuracy. Cable routing, shield termination, and grounding methods directly influence measurement stability.\u003c\/p\u003e\n\u003ch3\u003eRotor Dynamics Signal Considerations\u003c\/h3\u003e\n\u003cp\u003eAccelerometer systems differ from eddy-current proximity probe measurement chains because acceleration sensors directly measure casing vibration response rather than shaft displacement. Proper cable installation helps maintain the electrical characteristics required for vibration waveform analysis.\u003c\/p\u003e\n\u003cp\u003eFor systems containing multiple vibration measurement channels, correct shielding practices help reduce cross-talk suppression issues between adjacent signal circuits. Cable separation from high-current conductors is recommended to minimize induced noise.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 130539-17 3-Conductor Shielded Cable\u003c\/li\u003e\n\u003cli\u003e1 x Factory cable assembly with 3-socket plug and terminal lugs\u003c\/li\u003e\n\u003cli\u003e1 x Fluorosilicone elastomer boot installed on connector end\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eCable Routing\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the cable away from high-voltage power conductors and sources of electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eMaintain proper mechanical protection for exposed cable sections.\u003c\/li\u003e\n\u003cli\u003eAvoid sharp bending or excessive mechanical stress on connector areas.\u003c\/li\u003e\n\u003cli\u003eConfirm cable length requirements before installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eShield Grounding\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConnect cable shielding according to the machinery monitoring system grounding practice.\u003c\/li\u003e\n\u003cli\u003eAvoid improper shield termination that may introduce additional electrical noise.\u003c\/li\u003e\n\u003cli\u003eVerify terminal lug connections before commissioning vibration monitoring circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat equipment is the 130539-17 cable designed for?\u003c\/p\u003e\n\u003cp\u003eThe 130539-17 cable is designed for Bently Nevada 330400 and 330425 accelerometer connection applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many conductors are included in this cable?\u003c\/p\u003e\n\u003cp\u003eThe cable contains three conductors with an 18 AWG (1.0 mm2) conductor size and shielding layer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the operating temperature range?\u003c\/p\u003e\n\u003cp\u003eThe specified operating temperature range is -40 to +200 deg C for the cable assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat connector configuration is provided?\u003c\/p\u003e\n\u003cp\u003eOne end uses a 3-socket plug with a fluorosilicone elastomer boot, while the other end uses terminal lugs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum supported cable length?\u003c\/p\u003e\n\u003cp\u003eThe maximum specified cable length is 99 ft (30 m), with a minimum length of 2.0 ft (0.6 m).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 130539-17 cable suitable for acceleration signal transmission?\u003c\/p\u003e\n\u003cp\u003eYes. The cable is designed for electrical signal connection between accelerometers and vibration monitoring equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is cable shielding used in vibration systems?\u003c\/p\u003e\n\u003cp\u003eShielding helps reduce electrical interference that may affect low-level vibration measurement signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the cable require special installation practices?\u003c\/p\u003e\n\u003cp\u003eInstallation should follow standard vibration monitoring wiring practices, including proper routing and shield grounding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025980346541,"sku":"130539-17","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian10_5c71a8d8-5fe6-44ce-8ec6-5f1930b87649.jpg?v=1785741408","url":"https:\/\/www.maxwellplc.com\/ga\/products\/bently-nevada-130539-17-330400-330425-series-shielded-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}