{"product_id":"allen-bradley-powerflex-20f11gc043ja0nnnnn-frequency-ac-drive","title":"Allen-Bradley PowerFlex 20F11GC043JA0NNNNN Frequency AC drive","description":"\u003cp\u003eConfigured for frequency-controlled motor regulation in industrial drive systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20F11GC043JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e20F11GC043JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFrequency AC drive) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eDevice Configuration Profile\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Series: PowerFlex 753\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnclosure Rating: IP54, NEMA\/UL Type 12\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Rating: 400 VAC, 3 Phase\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Current: 43 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDuty Cycle: 22 kW (Normal Duty) \/ 18.5 kW (Heavy Duty)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBraking: Internal DB Transistor included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCM Protection: Jumper Installed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20F11GC043JA0NNNNN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21 x 59.5 x 17 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 kW (ND) \/ 18.5 kW (HD)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 VAC \/ 540 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNetwork and Control Integration\u003c\/h3\u003e\n\u003cp\u003eThe PowerFlex 753 architecture leverages EtherNet\/IP deterministic networks to enable real-time drive monitoring and feedback. The internal control logic supports I\/O density scaling, allowing for seamless integration into multi-axis automation platforms. Firmware flash compatibility is supported via the integrated communication ports, permitting systematic updates that align with existing control algorithms and safety-rated network configurations.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 unit 20F11GC043JA0NNNNN AC Drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 set of protective DC terminal covers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 technical documentation manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Orientation: The drive must be mounted in a vertical position on a flat, non-flammable surface to maintain optimal thermal heat sink dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental Protection: Due to the IP54 \/ NEMA 12 rating, ensure all conduit entry points are sealed with appropriate liquid-tight fittings to maintain enclosure integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding Requirements: Connect the drive chassis to a common earth ground using a low-impedance conductor to minimize potential differences during high-frequency switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Utilize shielded, twisted-pair motor cables with the shield terminated to the chassis at both the drive and motor ends to effectively attenuate radiated emissions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the drive support hot-swap of communication modules?\u003c\/p\u003e\n\u003cp\u003eYes, communication modules can be hot-swapped while the drive is energized, provided the control logic is not in an active Run state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the function of the installed CM jumper?\u003c\/p\u003e\n\u003cp\u003eThe CM jumper connects the common-mode capacitors to the chassis, providing a path for noise attenuation in grounded distribution systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this drive operate without a HIM?\u003c\/p\u003e\n\u003cp\u003eYes, the drive is designed for remote configuration via software and does not require a physical Human Interface Module for standard operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the thermal derating limit?\u003c\/p\u003e\n\u003cp\u003eOperation above 50 deg C requires specific derating of the carrier frequency or output current to prevent thermal shutdown of the power section.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this model include a dynamic braking transistor?\u003c\/p\u003e\n\u003cp\u003eYes, the model includes an internal DB transistor to manage regenerative energy during motor deceleration cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the firmware user-upgradeable?\u003c\/p\u003e\n\u003cp\u003eYes, firmware updates are performed through the peripheral interface port using compatible Allen-Bradley software tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the input DC bus compatibility?\u003c\/p\u003e\n\u003cp\u003eThe drive supports a common DC bus configuration at 540 VDC, intended for systems utilizing shared DC energy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre the I\/O terminals galvanically isolated?\u003c\/p\u003e\n\u003cp\u003eEmbedded I\/O terminals are optically isolated from the main control board logic to protect against surge transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066462130349,"sku":"20F11GC043JA0NNNNN","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20F1A-57_0cef263e-c16d-46ab-ba2f-e3547a6c6cae.jpg?v=1782451289","url":"https:\/\/www.maxwellplc.com\/ga\/products\/allen-bradley-powerflex-20f11gc043ja0nnnnn-frequency-ac-drive","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}