Model Identification
The 1785-ENET is an Ethernet communication expansion module designed for installation in a 1771 PLC-5 chassis. It connects directly to the PLC-5 processor communication path and provides Ethernet TCP/IP connectivity for PLC-5 controllers.
Compatible module revisions vary by PLC-5 processor family. Series and revision compatibility should be verified against the installed PLC-5 processor firmware and chassis configuration before replacement.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 1785-ENET |
| Brand | Allen-Bradley |
| Product Type | Ethernet Interface Module |
| Series | PLC-5 Series |
| Origin | USA |
| Weight | 0.96 kg |
| Shipping Dimensions | 3.3 x 14.8 x 27.4 cm |
| Operating Temp | 0 deg C to +60 deg C |
| Storage Temperature | -40 deg C to +85 deg C |
| Power Supply | 5 VDC from PLC-5 backplane |
| Backplane Current | 1.0 A @ 5 VDC |
| Power Dissipation | 5 W |
| Heat Dissipation | 17.06 BTU/hr |
| Communication Port | 8-pin RJ45 Ethernet port |
| Communication Protocol | Ethernet TCP/IP |
| Data Rate | 10/100 Mbps auto-negotiation |
| Isolation Voltage | 50 V |
| IEC Temperature Code | T5 |
Ethernet Communication Architecture
The 1785-ENET uses PLC-5 backplane communication to exchange controller data through an Ethernet TCP/IP network. The module provides a single RJ45 Ethernet interface with automatic network speed detection between 10 Mbps and 100 Mbps.
Status indication is provided through front-panel LEDs:
- STAT indicator monitors Ethernet link activity and module status.
- 100M indicator identifies operation on a 100 Mbps Ethernet connection.
- 10M indicator identifies operation on a 10 Mbps Ethernet connection.
The module supports Ethernet communication expansion for Enhanced PLC-5 controllers, Ethernet PLC-5 controllers, and ControlNet PLC-5 controller configurations depending on series and revision.
PLC-5 Network Integration Features
Allen-Bradley PLC-5 systems use a backplane-based architecture where communication modules exchange data through the chassis bus. The 1785-ENET maintains compatibility with PLC-5 processor families through defined series and firmware revisions.
EtherNet/IP deterministic networks require proper configuration of addressing, communication parameters, and controller compatibility. Firmware flash compatibility must be confirmed when replacing modules with different series revisions.
The module supports PLC-5 network expansion without changing the existing processor instruction structure, allowing Ethernet communication access through the PLC-5 controller environment.
Ordering Information
- 1 x Allen-Bradley 1785-ENET Ethernet Interface Module
- 1 x Factory-installed communication interface assembly
- 1 x Compatible mounting hardware assembly if supplied with the module configuration
- Manuals, programming software, and external Ethernet cables are not included unless specifically listed
Field Installation Guidelines
Power and Chassis Preparation
- Disconnect power from the 1771 I/O chassis before installation.
- Confirm PLC-5 processor compatibility with the module series and revision.
- Inspect the backplane connector condition before mounting.
Communication Wiring
- Use shielded Ethernet cabling suitable for the industrial environment.
- Maintain separation between communication wiring and high-voltage power conductors.
- Connect the RJ45 port securely and verify link status indicators after startup.
Module Installation
- Align the module with the PLC-5 chassis slot connector.
- Secure the module using the appropriate mounting hardware.
- Restore system power and verify Ethernet communication activity.
Frequently Asked Questions
- Is the 1785-ENET compatible with all PLC-5 processors?
The module compatibility depends on the PLC-5 processor family and firmware revision. Verify series and revision requirements before installation.
- Does the 1785-ENET require external power?
No. The module receives operating power from the PLC-5 backplane at 5 VDC.
- What Ethernet communication protocol does the module support?
The module supports Ethernet TCP/IP communication through an 8-pin RJ45 connector.
- What Ethernet speed is supported by the 1785-ENET?
The module supports 10 Mbps and 100 Mbps Ethernet operation with auto-negotiation capability.
- Can the 1785-ENET be hot-swapped during operation?
Hot insertion is not specified. Power should be removed before removing or installing the communication module.
- What is the backplane current requirement?
The module requires approximately 1.0 A from the PLC-5 backplane at 5 VDC.
- Does the module provide PLC-5 processor communication expansion?
Yes. It provides Ethernet communication expansion through direct connection with PLC-5 controller systems.
- What installation factor affects Ethernet communication performance?
Proper grounding, cable routing, network configuration, and connector installation affect communication stability.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.