{"product_id":"allen-bradley-2080-if2-micrologix-series-analog-plug-in-module","title":"Allen-Bradley 2080-IF2 MicroLogix Series Analog Plug-in Module","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 2080-IF2\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2080-IF2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Plug-in Module, operates as a dedicated hardware component for analog voltage and current signal acquisition within MicroLogix Series controllers. It interfaces directly via the specialized controller front-panel plug-in slots, transforming external field transmitter signals into high-resolution internal registers for logic processing.\u003c\/p\u003e\n\u003ch3\u003eHardware Designation Profile\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2080: Core catalog prefix for Micro800 \/ MicroLogix component accessories.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIF: Analog input hardware identification code.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2: Integer representation of the total physical single-ended input channel count.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2080-IF2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Plug-in Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Single-Ended Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Input Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0-10 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Input Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0-20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Resolution Data Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0-65535 counts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRepeatability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.1% of full scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Update Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e180 ms per enabled channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation Barrier\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-Isolation (Input Group to Bus \/ Channel to Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDerived from the host controller internal logic rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.2 cm x 4.5 cm x 12.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.15 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Integration and I\/O Scaling Parameters\u003c\/h3\u003e\n\u003cp\u003eThe plugin architecture mounts directly onto the host processor housing, optimizing localized I\/O density scaling without increasing the overall footprint of the DIN-rail cluster. The data transmission rate matches the backplane bus communication velocity licenses established by the processor. Complete firmware flash compatibility provides automated synchronization between the module conversion timing registers and the primary CPU task scheduler, which handles Profinet \/ EtherNet\/IP deterministic networks parameters at the controller boundary.\u003c\/p\u003e\n\u003ch3\u003eShipping Package Contents\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Allen-Bradley 2080-IF2 Analog Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Factory Warning Sheet and Component Card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModule Insertion Constraints\u003c\/p\u003e\n\u003cp\u003eTurn off all active electrical power lines feeding the base controller before inserting the plugin unit. Slide the module completely straight into the slot guide rails to avoid bending the internal gold-plated connector pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConductor Cable Shielding Rules\u003c\/p\u003e\n\u003cp\u003eWrap all analog transmitter signal lines in overall shielded, twisted-pair cabling. Ground the continuous shielding mesh at a single point on the main enclosure bulkhead plate to prevent electromagnetic ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring Layout Separations\u003c\/p\u003e\n\u003cp\u003eRoute the 0-10 VDC and 0-20 mA signal wires away from high-voltage AC motor wires and relay output cables to avoid noise cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this specific analog plug-in hardware support live hot-swap replacement when powered?\u003c\/p\u003e\n\u003cp\u003eNo, hot-swapping is not supported. You must isolate the main power supply from the base controller before installing or removing the plugin assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the precise electrical isolation rating between individual analog input channels?\u003c\/p\u003e\n\u003cp\u003eThis model features a non-isolated circuit layout, meaning there is no channel-to-channel or channel-to-controller bus electrical isolation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the module scale physical current loops into digital application registers?\u003c\/p\u003e\n\u003cp\u003eThe internal analog-to-digital converter converts the 0-10 VDC or 0-20 mA signal range linearly into an integer register spanning 0 to 65535 counts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan channel 0 handle a current loop while channel 1 concurrently records a voltage signal?\u003c\/p\u003e\n\u003cp\u003eYes, each input terminal path can be wired and configured in the software workspace independently for either voltage or current loop metrics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the response latency when both analog measurement channels are activated?\u003c\/p\u003e\n\u003cp\u003eThe conversion sequence requires an update period of 180 ms per active channel, resulting in a total cycle duration of 360 ms when both paths are enabled.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this module require specialized software licenses to communicate across the backplane bus?\u003c\/p\u003e\n\u003cp\u003eNo, the device utilizes standard hardware profiles included within the host controller programming environment without requiring additional communication velocity licenses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does operating altitude affect the voltage input limits of this component?\u003c\/p\u003e\n\u003cp\u003eThe hardware is rated to maintain standard dielectric performance up to a maximum operating altitude limit of 2000 m.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical check helps verify that firmware flash compatibility is aligned?\u003c\/p\u003e\n\u003cp\u003eThe configuration tool automatically reads the internal vendor ID and hardware series text upon controller power-up to confirm structural compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066460295341,"sku":"2080-IF2","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/2080-IF2-13.jpg?v=1784022279","url":"https:\/\/www.maxwellplc.com\/ga\/products\/allen-bradley-2080-if2-micrologix-series-analog-plug-in-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}