{"product_id":"allen-bradley-150-f970nbed-smart-motor-controller-bulletin-150-smc-flex","title":"Allen-Bradley 150-F970NBED Smart Motor Controller Bulletin 150 SMC Flex","description":"\u003cp\u003eConfigured for high-power induction motor acceleration control and braking execution in industrial distribution architectures, the \u003cb\u003eAllen-Bradley 150-F970NBED\u003c\/b\u003e (\u003cb\u003e150-F970\u003c\/b\u003e Solid-State Soft Starter) provides direct physical\/electrical execution. It directly manages continuous output ratings up to 970 A across 200...480 VAC three-phase utility lines. The internal power stack uses antiparallel silicon-controlled rectifiers (SCRs) to modulate voltage waveforms, suppressing high electromechanical torque transients during motor starting sequences and providing DC injection during active braking stops.\u003c\/p\u003e\n\u003ch3\u003ePart Number Structure \u0026amp; Nomenclature\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e150-F\u003c\/b\u003e: Identifies the Bulletin 150 SMC Flex solid-state soft starter platform.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e970\u003c\/b\u003e: Specifies the 970 A nominal continuous current capacity rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eN\u003c\/b\u003e: Standard open enclosure chassis (IP00 rated) intended for panel cabinet assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eB\u003c\/b\u003e: Operating main supply line voltage code covering 200...480 VAC, 3-Phase, 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eE\u003c\/b\u003e: Control circuit operating power voltage rating specified for 100...120 VAC (50\/60 Hz).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eD\u003c\/b\u003e: Factory-fitted internal option board designated for Smart Motor Braking (SMB) control algorithms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Physical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150-F970NBED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.06 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.8 x 24 x 21.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 W (Control Logic Board)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous Amperage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e970 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMotor Horsepower Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e800 HP @ 460 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMain Input Voltage Ue\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200...480 VAC, 3-Phase, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Power Supply Us\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100...120 VAC, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Class\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen (IP00)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Industrial Network Communications\u003c\/h3\u003e\n\u003cp\u003eThe soft starter links to ControlLogix and CompactLogix automation architectures through optional DPI communication cards. Interfacing via EtherNet\/IP deterministic networks enables direct backplane synchronization of process telemetry, including real-time thermal capacity utilization and operating current data. Upgraded controller logic ensures strict firmware flash compatibility across installed control modules, ensuring accurate SCR firing angle timing during high-current starting or controlled deceleration operations.\u003c\/p\u003e\n\u003ch3\u003eFulfillment Package Content\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Allen-Bradley 150-F970NBED SMC Flex Soft Starter Chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Factory-Installed Internal Braking Control Option Card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Hardware Lug Protective Cover Set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Panel Mounting Template and Wiring Guide Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Panel Mounting \u0026amp; Cabinet Wiring\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEnclosure Installation Rules\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMount the unit vertically onto an unpainted grounded steel plate inside an IP54 or NEMA 12 panel enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain a clear vertical spacing of at least 150 mm above and below the starter chassis to support convective heat transport.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring and Interference Prevention\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSegregate 100...120 VAC control wiring from main 3-phase high-voltage power conduits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the primary earth lug directly to the central panel earth bus bar via a heavy-gauge copper bonding jumper.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Questions and Answers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat input control voltage does the 150-F970NBED logic terminal block require?\u003c\/p\u003e\n\u003cp\u003eThe control circuit terminal block requires a dedicated single-phase AC control voltage input rated at 100...120 VAC at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat function does the integrated D suffix option perform?\u003c\/p\u003e\n\u003cp\u003eThe D option designates an integrated braking option module designed for Smart Motor Braking (SMB) without external electromechanical brakes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the 150-F970NBED starter be mounted in an outdoor environment without a cabinet?\u003c\/p\u003e\n\u003cp\u003eNo, the unit features an Open IP00 frame rating and must be housed inside a protective industrial enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit manage thermal dissipation when the motor reaches full speed?\u003c\/p\u003e\n\u003cp\u003eInternal bypass contactors close automatically once full voltage output is achieved, bypassing the power SCRs to lower operating heat.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the unit capable of updating internal control logic via network tools?\u003c\/p\u003e\n\u003cp\u003eYes, the controller supports firmware flash compatibility using standard DPI fieldbus communication adapters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat protective functions does the internal electronic module execute?\u003c\/p\u003e\n\u003cp\u003eIt executes electronic motor overload protection, SCR shorted-gate monitoring, supply phase unbalance checks, and thermal over-temperature limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre low-voltage control terminals isolated from high-voltage main lines?\u003c\/p\u003e\n\u003cp\u003eYes, internal isolation transformers and optocouplers provide galvanic separation between low-voltage control terminals and line power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are trip logic conditions cleared following an emergency stop fault?\u003c\/p\u003e\n\u003cp\u003eFaults are cleared by applying a signal to the reset terminal, cycling control power, or issuing a network reset command over EtherNet\/IP.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066398396589,"sku":"150-F970NBED","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/150-F6_6-5_520518a8-535f-4ec1-85aa-4925ff27be77.jpg?v=1786075097","url":"https:\/\/www.maxwellplc.com\/ga\/products\/allen-bradley-150-f970nbed-smart-motor-controller-bulletin-150-smc-flex","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}