{"product_id":"abb-sa610-3bht300019r1-power-supply-module-ac110-160-series","title":"ABB SA610 3BHT300019R1 Power Supply Module AC110\/160 Series","description":"\u003cp\u003eThe \u003cstrong\u003eABB SA610 3BHT300019R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSA610\u003c\/strong\u003e Power Supply, operates as a dedicated hardware component for 24 VDC bus power conversion and regulation within Advant Controller AC110\/160 platforms.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model Family:\u003c\/strong\u003e SA610\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Part Number:\u003c\/strong\u003e 3BHT300019R1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Parameters:\u003c\/strong\u003e SA 610 Power Supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Platform:\u003c\/strong\u003e Advant Controller AC110 \/ AC160\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Output Power:\u003c\/strong\u003e 240 W (24 VDC at 10 A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConversion Efficiency:\u003c\/strong\u003e \u0026gt; 90% (typical at full load)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarmonized Tariff Code:\u003c\/strong\u003e 8537101190\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSA610 3BHT300019R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.66 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.0 cm x 26.0 cm x 27.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e4.0 cm x 26.0 cm x 27.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C (-13 to +158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePower supply unit (240 W output rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 370 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (+\/-1% typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e10 A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple \/ Noise\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1% peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Backplane Bus Infrastructure \u0026amp; Power Density\u003c\/h3\u003e\n\u003cp\u003eThe SA610 3BHT300019R1 module feeds regulated 24 VDC current directly into the AC110\/160 system backplane bus, driving subrack card slots and internal logic processors. The power unit incorporates internal high-frequency switching architecture operating at greater than 90% efficiency, suppressing thermal dissipation while maintaining deterministic voltage regulation under full 10 A load steps. Backplane voltage stability is buffered against supply transients, preventing voltage drops across I\/O module communication logic and controller sub-buses.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x ABB SA610 3BHT300019R1 Power Supply Unit\u003c\/li\u003e\n\u003cli\u003e1x Factory hardware specification documentation sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubrack Placement:\u003c\/strong\u003e Align the SA610 module with the dedicated power supply slot of the AC110\/160 subrack. Slide the unit along the chassis guide rails until the rear high-current connector locks into the backplane motherboard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Input Cabling:\u003c\/strong\u003e Wire line, neutral, and protective earth conductors using stranded copper wire rated for 300 V \/ 105 deg C (minimum AWG 14). Torque terminal retention screws to 0.6 N m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e Secure a direct low-impedance bond between the subrack chassis earth terminal and the main ground bus, ensuring a earth bond resistance below 0.1 Ohm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Clearances:\u003c\/strong\u003e Ensure unimpeded vertical forced-air airflow across the top and bottom ventilation grilles of the subrack assembly to maintain operation across the -25 to +70 deg C thermal envelope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the SA610 power supply permit hot-swapping during active backplane operation?\u003c\/p\u003e\n\u003cp\u003eNo. Main AC\/DC primary supply lines must be isolated before inserting or removing the SA610 module to prevent backplane connector arcing and bus transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat input supply sources are supported by the primary terminals?\u003c\/p\u003e\n\u003cp\u003eThe unit accepts wide-range AC inputs from 85 to 264 VAC (47 to 63 Hz) and DC inputs from 100 to 370 VDC without physical jumper configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is output voltage regulation maintained across varying current loads?\u003c\/p\u003e\n\u003cp\u003eInternal feedback circuits hold the output at 24 VDC within a +\/-1% typical tolerance band across the entire 0 to 10 A continuous output current range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output ripple voltage is present on the 24 VDC system rail?\u003c\/p\u003e\n\u003cp\u003eOutput voltage ripple and switching noise are filtered to under 1% peak-to-peak relative to the 24 VDC nominal output rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat protection mechanisms trigger during an overcurrent event on the output?\u003c\/p\u003e\n\u003cp\u003eThe internal power circuit implements current limiting to restrict output power to its 240 W max ceiling, automatically recovering upon fault removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the recommended grounding conductor size for the power supply rack?\u003c\/p\u003e\n\u003cp\u003eUse a copper grounding conductor of at least 2.5 mm2 (AWG 12) connected directly to the subrack functional protective earth terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat storage environment limits apply to spare SA610 power modules?\u003c\/p\u003e\n\u003cp\u003eModules must be stored in unpowered packaging within an ambient temperature range of -40 to +85 deg C and relative humidity under 95% non-condensing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the power supply require forced-air fan cooling inside the panel cabinet?\u003c\/p\u003e\n\u003cp\u003eNatural convection cooling is supported up to full rated output provided a 100 mm clear vertical space is maintained above and below the card cage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021148967085,"sku":"SA610 3BHT300019R1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_sa610_3bht300019r1_1.jpg?v=1788327588","url":"https:\/\/www.maxwellplc.com\/ga\/products\/abb-sa610-3bht300019r1-power-supply-module-ac110-160-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}