{"product_id":"abb-pm566-tp-eth-ac500-eco-cpu-processors-1sap121500r0071","title":"ABB PM566-TP-ETH AC500-eCo CPU Processors 1SAP121500R0071","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePM566-TP-ETH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e1SAP121500R0071\u003c\/strong\u003e)\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPU Processor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePM566-TP-ETH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPU Processor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eused to execute control or monitoring functions across automation platforms. This controller is designed for the AC500-eCo range, providing localized logic execution for small-scale industrial applications. It integrates essential processing power with onboard I\/O capabilities, facilitating direct interface with field devices. The architecture allows for scalable expansion using S500 and S500-eCo modules, ensuring that the controller can be adapted to specific signal requirements within factory automation or machine control environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePM566-TP-ETH (1SAP121500R0071)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContact manufacturer for specific facility\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.282 kg (Net)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.4 x 8.2 x 13.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (20.4–28.8 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x Ethernet, 1x RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e642 kB (RAM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBrand-Specific Technical Block\u003c\/h3\u003e\n\u003cp\u003eThe PM566-TP-ETH utilizes ABB backplane communication protocols to facilitate high-speed data exchange between the CPU and attached I\/O modules. The processor firmware is optimized for the AC500-eCo architecture, supporting consistent cycle times and stable logic execution. Connectivity is managed through integrated Ethernet and RS-485 interfaces, allowing the module to act as a node in wider industrial networks. I\/O density can be increased via the system bus, and the controller maintains firmware compatibility with standard ABB programming environments to ensure seamless integration within larger AC500 system topologies.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIncluded items: CPU Module, pluggable terminal blocks, documentation guide.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard package: Industrial anti-static sealed enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional accessories: SD memory cards for program storage, DIN rail mounting clips, communication cable kits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount the unit on a standard 35 mm DIN rail in a vertical orientation to ensure optimal heat dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the 24 V DC power supply using appropriately sized copper conductors, ensuring polarity is observed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround the module chassis to the cabinet common earth to minimize electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure field wiring is shielded and routed away from high-voltage AC cables to maintain signal integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the secure connection of all pluggable terminal blocks before applying power to the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRespect the minimum clearance requirements around the device to ensure unobstructed airflow for thermal regulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the PM566-TP-ETH support hot-swap behavior?\u003c\/p\u003e\n\u003cp\u003eA: The module does not support hot-swapping; power must be removed from the system before installation or removal of the unit.\u003c\/p\u003e\n\u003cp\u003eQ: How does the unit manage backplane load?\u003c\/p\u003e\n\u003cp\u003eA: The internal power supply provides a limited current to the local backplane bus; expansion modules must not exceed the specified power budget.\u003c\/p\u003e\n\u003cp\u003eQ: What is the redundancy switching delay for this unit?\u003c\/p\u003e\n\u003cp\u003eA: This CPU model is intended for standalone or non-redundant configurations and does not feature active redundancy switching logic.\u003c\/p\u003e\n\u003cp\u003eQ: Is firmware compatibility required for expanded I\/O?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CPU firmware must be verified against the catalog version of any S500\/S500-eCo expansion modules attached to the system.\u003c\/p\u003e\n\u003cp\u003eQ: Does the unit provide signal isolation?\u003c\/p\u003e\n\u003cp\u003eA: The onboard digital and analog I\/O are isolated from the CPU logic circuits as per standard AC500-eCo design specifications.\u003c\/p\u003e\n\u003cp\u003eQ: What are the field wiring constraints?\u003c\/p\u003e\n\u003cp\u003eA: Use flexible or stranded wire with proper ferrules, adhering to the terminal block capacity specifications to ensure reliable electrical contact.\u003c\/p\u003e\n\u003cp\u003eQ: Can the RS-485 port be used for fieldbus master configuration?\u003c\/p\u003e\n\u003cp\u003eA: The RS-485 port supports standard serial protocols; configuration depends on the specific project setup in the programming software.\u003c\/p\u003e\n\u003cp\u003eQ: How is the processing time affected by I\/O load?\u003c\/p\u003e\n\u003cp\u003eA: Increased I\/O configuration may slightly alter scan cycle times; monitor execution timing via the system diagnostic tools.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231187132589,"sku":"PM566-TP-EYH","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-pm566-tp-eyh-programmable-logic-controller-q5f3afbp2ai_e520f6a5-721d-4217-be9b-3381524ddeb9.jpg?v=1762942396","url":"https:\/\/www.maxwellplc.com\/ga\/products\/abb-pm566-tp-eth-ac500-eco-cpu-processors-1sap121500r0071","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}