{"product_id":"abb-l700743a3-10-infi-90-analog-termination-cable","title":"ABB L700743A3-10 Infi 90 Analog Termination Cable","description":"\u003cp\u003eThe \u003cstrong\u003eABB L700743A3-10\u003c\/strong\u003e analog termination cable provides secure signal routing and termination for 4–20 mA current loops, 0–10 VDC or ±5 VDC voltage signals, and RTD temperature sensors within ABB Infi 90 control environments. Engineered with 10 twisted pairs and a 22 AWG conductor gauge, this 10-meter cable maintains reliable signal integrity across demanding industrial process control installations.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration\u003c\/h3\u003e\n\u003cp\u003eThe complete ordering code \u003cstrong\u003eL700743A3-10\u003c\/strong\u003e incorporates specific physical and electrical configuration parameters:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e L700743A3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength Suffix (-10):\u003c\/strong\u003e Indicates a total cable length of 10 meters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Analog termination and signal transmission for multi-channel I\/O cards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eL700743A3-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Termination Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eInfi 90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.84 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e61 x 11 x 7.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Gauge\u003c\/td\u003e\n\u003ctd\u003e22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Pairs\u003c\/td\u003e\n\u003ctd\u003e10 twisted pairs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance\u003c\/td\u003e\n\u003ctd\u003e100 ohms (typical for analog signals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003eLess than 60 pF\/m (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e4–20 mA, 0–10 VDC, ±5 VDC, RTD (Pt100\/1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0 - 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication and Controller Compatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned specifically for the ABB Infi 90 distributed control system architecture, the \u003cstrong\u003eL700743A3-10\u003c\/strong\u003e links field termination units to controller or I\/O module backplanes. The 10 twisted-pair configuration provides channel separation to minimize crosstalk in multi-loop analog implementations. The characteristic impedance of 100 ohms and low capacitance profile (under 60 pF\/m) preserve measurement accuracy for low-level analog, voltage, and RTD temperature inputs over the 10-meter run.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Electrical Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRouting and Bending:\u003c\/strong\u003e Maintain a minimum bend radius of at least 8 times the overall cable diameter during installation to prevent conductor stress or insulation damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Separation:\u003c\/strong\u003e Route analog signal cables away from high-voltage power lines and variable frequency drives to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Ensure proper shield termination at designated grounding bars to maintain common-mode noise rejection across the 4–20 mA loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Limits:\u003c\/strong\u003e Verify that the installation area remains within the operating temperature range of -30 deg C to +70 deg C and 0–95% RH non-condensing humidity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspection:\u003c\/strong\u003e Inspect connectors and pins for debris or oxidation prior to mating with Infi 90 termination assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the exact length of the L700743A3-10 cable?\u003c\/p\u003e\n\u003cp\u003eA: The \"-10\" suffix indicates a standard factory cable length of 10 meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What signal types are supported by this termination cable?\u003c\/p\u003e\n\u003cp\u003eA: It supports 4–20 mA current loops, 0–10 VDC and ±5 VDC voltage signals, and RTD sensors including Pt100 and Pt1000 configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the conductor configuration inside the cable jacket?\u003c\/p\u003e\n\u003cp\u003eA: The cable contains 10 twisted pairs of 22 AWG conductors designed to reduce crosstalk in multi-channel analog loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the nominal characteristic impedance of the signal lines?\u003c\/p\u003e\n\u003cp\u003eA: The typical characteristic impedance is 100 ohms, matched for standard industrial analog control instrumentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What are the acceptable operating temperature limits?\u003c\/p\u003e\n\u003cp\u003eA: The cable operates reliably in environments ranging from -30 deg C to +70 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this cable be used outside of ABB Infi 90 systems?\u003c\/p\u003e\n\u003cp\u003eA: While physically compatible with matching connector interfaces, the cable is engineered specifically for Infi 90 analog termination schemes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What minimum bend radius must be observed during installation?\u003c\/p\u003e\n\u003cp\u003eA: Installers must maintain a minimum bend radius of at least 8 times the overall cable diameter to protect internal conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the weight of the packaged unit for shipping calculations?\u003c\/p\u003e\n\u003cp\u003eA: The individual product weight is 0.84 kg, with estimated shipping dimensions of 61 x 11 x 7.5 cm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021040046253,"sku":"L700743A3-10","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nkls013.jpg?v=1789277883","url":"https:\/\/www.maxwellplc.com\/ga\/products\/abb-l700743a3-10-infi-90-analog-termination-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}