{"product_id":"abb-imasm02-analog-input-slave-module-infi-90","title":"ABB IMASM02 Analog Input Slave Module Infi 90","description":"\u003cp\u003eConfigured for multi-channel field signal acquisition in Bailey Infi 90 architectures, the \u003cstrong\u003eABB IMASM02\u003c\/strong\u003e (\u003cstrong\u003eIMASM02\u003c\/strong\u003e Analog Input Slave Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Variant Functional Architecture\u003c\/h3\u003e\n\u003cp\u003eThe IMASM02 functions as an 8-channel analog input expansion unit within the Infi 90 slave module family. The base designation IMASM identifies the analog slave module class, while the suffix 02 denotes double-threaded pin mounting hardware and flexible field signal processing across 4-20 mA current loops, 0-10 VDC levels, thermocouples, and RTD sensors under a master module controller.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIMASM02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e17.8 x 5.1 x 33.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.5 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e15 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signals\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-10 V, thermocouple, RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDouble threaded pin mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5-95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Subsystem Bus Integration\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with an analog master module over dedicated backplane bus pathways, maintaining high backplane bus communication velocity across all 8 channels. Integrated 16-bit digitizing circuitry delivers deterministic signal scaling to host master units while preserving I\/O density scaling and maintaining cross-system firmware flash compatibility across active processing racks.\u003c\/p\u003e\n\u003ch3\u003ePackage Scope\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB IMASM02 Analog Input Slave Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Mounting and Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEngage double-threaded pin mounting hardware securely to prevent vibration-induced backplane contact loss.\u003c\/li\u003e\n\u003cli\u003eRoute field analog wiring in shielded twisted pairs separated from AC power lines by at least 300 mm.\u003c\/li\u003e\n\u003cli\u003eConnect shield drain wires to designated cabinet earth bars to eliminate signal offset errors.\u003c\/li\u003e\n\u003cli\u003eEnsure power is turned off to the module rack prior to inserting or unseating the board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the supply voltage required for the IMASM02?\u003c\/p\u003e\n\u003cp\u003eThe module requires a regulated 15 VDC power rail supplied via the internal rack backplane interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many field input channels are available on a single module?\u003c\/p\u003e\n\u003cp\u003eThe IMASM02 supports up to 8 individual analog input channels per module assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal types can be wired directly to the input channels?\u003c\/p\u003e\n\u003cp\u003eInputs accept 4-20 mA current, 0-10 VDC voltage, thermocouples, and RTD temperature sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat power rating is drawn by the module during operation?\u003c\/p\u003e\n\u003cp\u003eThe total operational power rating of the module circuit board is 2.5 VA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the conversion resolution of the onboard analog interface?\u003c\/p\u003e\n\u003cp\u003eAnalog signals are converted into digital values using a high-precision 16-bit converter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat mounting method secures the module within the rack slot?\u003c\/p\u003e\n\u003cp\u003eThe card uses double-threaded pin mounting to maintain mechanical retention inside the chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes replacing an IMASM02 require system recalibration?\u003c\/p\u003e\n\u003cp\u003eNo, hardware calibration constants are managed and retained by the supervising analog master module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the operating temperature range for industrial enclosure deployment?\u003c\/p\u003e\n\u003cp\u003eThe module operates continuously across ambient panel temperatures from 0 to +60 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021109252269,"sku":"IMASM02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/imasm02_5.jpg?v=1789279500","url":"https:\/\/www.maxwellplc.com\/ga\/products\/abb-imasm02-analog-input-slave-module-infi-90","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}