{"product_id":"abb-icso08r1-fpr3312101r0024-procontic-cs31-series-binary-output-unit","title":"ABB ICSO08R1 FPR3312101R0024 Procontic CS31 Series Binary Output Unit","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB ICSO08R1 FPR3312101R0024\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eICSO08R1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBinary Output Unit, operates as a dedicated hardware component for 120 VAC discrete load control and switching within Procontic CS31 networks.\u003c\/p\u003e\n\u003ch3\u003eProduct Part Number \u0026amp; Identifier Structure\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Product Model:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eICSO08R1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing Order Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFPR3312101R0024\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage Class:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e120 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProcontic CS31 Fieldbus System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eICSO08R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.66 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.0 x 6.0 x 11.6 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC Binary\/Discrete Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBus Communication Velocity \u0026amp; Control Integration\u003c\/h3\u003e\n\u003cp\u003eThe ICSO08R1 binary output unit integrates into the Procontic CS31 fieldbus topology, processing digital output commands sent from the host central processing unit. Designed for deterministic switching execution, the module maintains backplane bus communication velocity and strict firmware flash compatibility across CS31 system racks. Optocoupler isolation between the internal CS31 bus logic and the 120 VAC field load terminals prevents transient voltage surges from corrupting backplane communication.\u003c\/p\u003e\n\u003ch3\u003ePackage Delivery Contents\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x ABB ICSO08R1 (FPR3312101R0024) Binary Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePanel Mounting \u0026amp; Wiring Execution Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eShut off main cabinet power and isolate field supply lines before initiating installation or wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSnap the module firmly onto a standard DIN rail, verifying that the rear locking clip engages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the CS31 twisted-pair bus lines to the dedicated communication terminals using proper shielding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWire 120 VAC field load circuits to output screw terminals, ensuring tight mechanical torque on all connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify solid protective earth (PE) connection to the chassis frame to divert high-frequency industrial noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat primary function does the ICSO08R1 module execute in a Procontic CS31 system?\u003c\/p\u003e\n\u003cp\u003eThe ICSO08R1 acts as a remote binary output interface that converts CS31 bus control commands into switching signals for 120 VAC field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the ICSO08R1 be hot-swapped while the CS31 bus is actively communicating?\u003c\/p\u003e\n\u003cp\u003eNo. Field bus power and 120 VAC load supply lines must be disconnected before removing or inserting the unit to avoid communication bus errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are field-side electrical surges isolated from the CPU logic bus?\u003c\/p\u003e\n\u003cp\u003eThe unit incorporates optical isolation between internal digital control circuitry and the 120 VAC field terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the physical dimensions and weight of the shipping package?\u003c\/p\u003e\n\u003cp\u003eThe shipping package measures 12.0 x 6.0 x 11.6 cm and has an overall weight of 0.66 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this unit require manual firmware flashing before field commissioning?\u003c\/p\u003e\n\u003cp\u003eNo. The ICSO08R1 functions with embedded hardware control logic compatible with standard Procontic CS31 master CPU firmware profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the binary output module mounted inside an enclosure?\u003c\/p\u003e\n\u003cp\u003eThe module features a rear DIN-rail mounting channel designed to lock securely onto standard 35 mm mounting rails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat field devices can be directly driven by the 120 VAC outputs?\u003c\/p\u003e\n\u003cp\u003eIt is designed to switch 120 VAC industrial field loads such as motor contactors, solenoid valves, indicator lamps, and control relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is field bus signal noise mitigated on long cable runs?\u003c\/p\u003e\n\u003cp\u003eThe unit interfaces with shielded twisted-pair RS485 communication media, requiring proper cable shield termination to ground at the bus connection nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021157748909,"sku":"ICSO08R1","price":818.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_icso08r1_fpr3312101r0024_1.jpg?v=1787450122","url":"https:\/\/www.maxwellplc.com\/ga\/products\/abb-icso08r1-fpr3312101r0024-procontic-cs31-series-binary-output-unit","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}