{"product_id":"abb-do810-ea-3bse008510r2-digital-output-module-s800-i-o","title":"ABB DO810-eA 3BSE008510R2 Digital Output Module S800 I\/O","description":"\u003cp\u003eConfigured for discrete signal actuation in S800 I\/O distributed control network platforms, the \u003cstrong\u003eABB DO810-eA\u003c\/strong\u003e (\u003cstrong\u003e3BSE008510R2\u003c\/strong\u003e Digital Output Module) provides direct physical electrical execution for field-level process interlocks and command sequences.\u003c\/p\u003e\n\u003ch3\u003eMechanical and Electrical Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO810-eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e4.5 x 11 x 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e5 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eTransistor (Source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication and I\/O Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module utilizes the MTU (Module Termination Unit) to interface with the S800 I\/O backplane. Data exchange occurs via a deterministic bus protocol, supporting high-speed status polling and command execution. The internal firmware maintains compatibility with standard S800 system controllers, ensuring consistent I\/O density scaling during field expansion. Deterministic timing is maintained through integrated bus arbitration logic, preventing signal latency in distributed control topologies.\u003c\/p\u003e\n\u003ch3\u003eLogistics and Scope of Supply\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 unit: DO810-eA Digital Output Module\u003c\/li\u003e\n\u003cli\u003e1 unit: Plastic housing and integrated terminal block interface (MTU sold separately)\u003c\/li\u003e\n\u003cli\u003e1 unit: Factory conformity documentation (Safety and technical specifications)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMounting Requirements:\n\u003cul\u003e\n\u003cli\u003eSecure the MTU onto a standard 35 mm DIN rail prior to module insertion.\u003c\/li\u003e\n\u003cli\u003eEnsure the mechanical locking clip is fully engaged to maintain backplane bus contact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eWiring Standards:\n\u003cul\u003e\n\u003cli\u003eUtilize shielded twisted-pair cabling for all digital output loops to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eVerify signal commonality and voltage polarity at the terminal block before energizing the 24 VDC supply.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum distance of 50 mm from high-voltage power lines to prevent induced signal errors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Query Resolution\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the DO810-eA support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swapping within the S800 I\/O system, allowing for replacement without de-energizing the main backplane power or the system controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the output channel galvanically isolated?\u003c\/p\u003e\n\u003cp\u003eA: The module provides optical isolation between the field-side output circuits and the backplane logic circuitry to protect the controller from transient surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum current rating per output channel?\u003c\/p\u003e\n\u003cp\u003eA: Each channel is rated for a specific continuous current load, typically 0.5 A. Refer to the specific hardware revision load curve for inductive load de-rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this module be configured for redundant operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module is compatible with S800 redundant I\/O configurations when paired with appropriate redundant MTUs and controller software setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the eA suffix?\u003c\/p\u003e\n\u003cp\u003eA: The eA suffix denotes a specific revision or production variant of the DO810 module, indicating internal component adjustments or firmware-specific iterations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the module powered?\u003c\/p\u003e\n\u003cp\u003eA: The module is powered via the S800 I\/O backplane 24 VDC process power rail, which must be connected to an appropriately sized power distribution unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum backplane communication speed?\u003c\/p\u003e\n\u003cp\u003eA: The communication speed is governed by the system controller and the specific I\/O bus cycle time settings, ensuring deterministic timing for all connected modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this module with different MTU types?\u003c\/p\u003e\n\u003cp\u003eA: Compatibility is restricted to S800-series MTUs that support the specific pin-out configuration of the DO810-eA. Always verify the MTU part number.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021160337581,"sku":"DO810-eA","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/DO810-eA_1.jpg?v=1783413846","url":"https:\/\/www.maxwellplc.com\/ga\/products\/abb-do810-ea-3bse008510r2-digital-output-module-s800-i-o","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}