{"product_id":"abb-di651-3bht300026r1-digital-input-module-ac110-160","title":"ABB DI651 3BHT300026R1 Digital Input Module AC110\/160","description":"\u003cp\u003eConfigured for discrete state sensing in AC110\/160 systems, the \u003cstrong\u003eABB DI651 3BHT300026R1\u003c\/strong\u003e (\u003cstrong\u003eDI651\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eComponent Identity \u0026amp; Model Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase Model: DI651\u003c\/li\u003e\n\u003cli\u003ePart Number: 3BHT300026R1\u003c\/li\u003e\n\u003cli\u003eCatalog Designation: 3BHT300026R1\u003c\/li\u003e\n\u003cli\u003eSystem Family: ABB Advant Controller 110 \/ AC160 Platform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Data Summary\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDI651 3BHT300026R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e4.0 x 26.5 x 27.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +70 deg C (-13 deg F to +158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Level (ON)\u003c\/td\u003e\n\u003ctd\u003e15 VDC to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Level (OFF)\u003c\/td\u003e\n\u003ctd\u003e0 VDC to 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e2 mA to 5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Channel Isolation\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField-to-System Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e5 Hz to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication Velocity \u0026amp; System Interface\u003c\/h3\u003e\n\u003cp\u003eThe DI651 module maintains synchronous signal transfers to processing units using optimized backplane bus communication velocity protocols. Built-in I\/O density scaling allows rapid polling across all 16 isolated channels. Direct memory mapping ensures real-time operational response without risking backplane buffer saturation during transient load changes.\u003c\/p\u003e\n\u003ch3\u003ePackage Inventory\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB DI651 3BHT300026R1 Digital Input Module\u003c\/li\u003e\n\u003cli\u003eStandard industrial protective packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation \u0026amp; Wiring Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRack Slot Engagement\n\u003cul\u003e\n\u003cli\u003eAlign upper and lower PCB edge guides precisely within the subrack slot prior to pushing the assembly inward to safeguard backplane pin connectors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eGrounding and Shield Termination\n\u003cul\u003e\n\u003cli\u003eConnect signal cable shields directly to field terminal rail grounding bars. Ensure low-impedance connection points to prevent electrical noise interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eWiring Separation Rules\n\u003cul\u003e\n\u003cli\u003eMaintain physical separation between 24 VDC signal wiring and high-voltage AC distribution conductors inside the enclosure ducts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Diagnostics \u0026amp; Technical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the specific voltage levels defined for ON and OFF states?\u003c\/p\u003e\n\u003cp\u003eLogic state HIGH requires 15 VDC to 30 VDC, while logic state LOW corresponds to 0 VDC to 5 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat degree of isolation is provided between individual channels?\u003c\/p\u003e\n\u003cp\u003eChannel-to-channel isolation withstands potentials up to 500 VAC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat level of galvanic isolation protects the backplane bus?\u003c\/p\u003e\n\u003cp\u003eField-to-system electrical isolation is rated at 1500 VAC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat current range does each channel draw during active signal detection?\u003c\/p\u003e\n\u003cp\u003eEach channel draws approximately 2 mA to 5 mA depending on field voltage levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat vibration frequencies can the hardware withstand?\u003c\/p\u003e\n\u003cp\u003eThe module withstands field vibration test sweeps across 5 Hz to 500 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the allowed storage temperature parameters?\u003c\/p\u003e\n\u003cp\u003eStorage conditions must be maintained between -40 deg C and +85 deg C (-40 deg F to +185 deg F).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many field inputs can be monitored on a single card?\u003c\/p\u003e\n\u003cp\u003eThe module provides 16 individual digital input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ambient humidity range is permissible during operation?\u003c\/p\u003e\n\u003cp\u003eOperating humidity must remain between 5% and 95% non-condensing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021135859885,"sku":"DI651 3BHT300026R1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_di651_3bht300026r1_2.jpg?v=1788324620","url":"https:\/\/www.maxwellplc.com\/ga\/products\/abb-di651-3bht300026r1-digital-input-module-ac110-160","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}