{"product_id":"abb-acs-580-acs580mv-2uba014272r0007-ac-servo-drive-amplifier-controller","title":"ABB ACS 580 ACS580MV 2UBA014272R0007 AC Servo Drive Amplifier Controller","description":"\u003cp\u003eThe \u003cstrong\u003eABB ACS580MV 2UBA014272R0007\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eACS580MV\u003c\/strong\u003e AC servo drive amplifier controller, operates as a dedicated hardware component for high-current phase switching and real-time motor torque generation within ACS580 drive lineups.\u003c\/p\u003e\n\u003ch3\u003eSystem Ordering \u0026amp; Model Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Ordering Code\u003c\/strong\u003e: 2UBA014272R0007\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Module Family\u003c\/strong\u003e: ACS580MV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrive Control Topology\u003c\/strong\u003e: Sensorless Vector Control (SLVC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Output Bandwidth\u003c\/strong\u003e: 0.75 kW to 560 kW dynamic power scaling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Carrying Capacity\u003c\/strong\u003e: 1300 A rated output current\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Matrix\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eACS580MV (2UBA014272R0007)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e23.2 cm x 10.6 cm x 13.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +40 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePhase power dissipation managed via internal cooling channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e200 to 690 VAC (3-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003eMatches input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Current Rating\u003c\/td\u003e\n\u003ctd\u003e1300 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTorque Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-5 % (SLVC mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Regulation Range\u003c\/td\u003e\n\u003ctd\u003e1:100 (SLVC mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Backplane \u0026amp; Firmware Execution\u003c\/h3\u003e\n\u003cp\u003eThe controller relies on backplane bus communication velocity licences to exchange torque and velocity parameters at microsecond cycle rates. Connected via Profinet \/ EtherNet\/IP deterministic networks, internal gate firing commands maintain nanosecond synchronization across power semiconductors. In-system firmware flash compatibility allows online software updates while preventing communication packet collision during operation.\u003c\/p\u003e\n\u003ch3\u003eScope of Delivery \u0026amp; Ordering Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB ACS580MV amplifier controller unit (2UBA014272R0007)\u003c\/li\u003e\n\u003cli\u003e1 x Optical control bus interface harness\u003c\/li\u003e\n\u003cli\u003e1 x Hardware mounting kit and ground strap assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Field Installation Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Voltage De-energization\u003c\/strong\u003e: Isolate main 3-phase AC power lines and allow at least 5 minutes for internal DC bus energy dissipation before touching physical electrical contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Connection\u003c\/strong\u003e: Secure the frame grounding strap to the cabinet ground bar using serrated lock washers to establish a low-impedance ground path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber Optic Routing\u003c\/strong\u003e: Secure optical transmission cables with a minimum bend radius of 35 mm to avoid signal degradation between the main control module and power stage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvection Clearance\u003c\/strong\u003e: Maintain clear vertical airflow passages around the unit heat sink structure to ensure proper thermal dissipation inside the housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat speed regulation ratio is supported by this amplifier unit under sensorless vector control?\u003c\/p\u003e\n\u003cp\u003eThe unit provides a 1:100 speed control range without requiring external encoder feedback under Sensorless Vector Control (SLVC) mode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat torque control accuracy is achieved during standard operating cycles?\u003c\/p\u003e\n\u003cp\u003eThe controller maintains a torque output accuracy within +\/-5 % of rated motor torque across the SLVC operating range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this drive amplifier unit be hot-swapped while the VFD cabinet is energized?\u003c\/p\u003e\n\u003cp\u003eHot-swapping is prohibited; all primary AC input voltage and auxiliary power sources must be disconnected before board insertion or removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat peak output current level can be sustained by the power switching assembly?\u003c\/p\u003e\n\u003cp\u003eThe power stage hardware is engineered to support a continuous current rating up to 1300 A under nominal operating conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat line input voltage parameters are accepted by the amplifier power stage?\u003c\/p\u003e\n\u003cp\u003eThe power input stage accepts 3-phase AC line supplies ranging from 200 to 690 VAC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are real-time gating signals transmitted from the central processing CPU to this card?\u003c\/p\u003e\n\u003cp\u003eCommands are sent over noise-immune fiber optic lines to isolate low-voltage control loops from high-voltage semiconductor switching spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat firmware precautions are necessary when replacing an existing module?\u003c\/p\u003e\n\u003cp\u003eEnsure firmware flash compatibility matches the revision running on the main system processor to avoid communication arbitration errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ambient temperature boundaries apply to this amplifier unit?\u003c\/p\u003e\n\u003cp\u003eThe module operates reliably within an ambient temperature window of 0 to +40 deg C inside the drive cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021052432557,"sku":"ACS580MV 2UBA014272R0007","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/2uba014272r0007_2.jpg?v=1791954864","url":"https:\/\/www.maxwellplc.com\/ga\/products\/abb-acs-580-acs580mv-2uba014272r0007-ac-servo-drive-amplifier-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}