{"product_id":"abb-3bse007137r1-pfvo131-panel-unit-ac110-160-series","title":"ABB 3BSE007137R1 PFVO131 Panel Unit AC110\/160 Series","description":"\u003cp\u003eThe \u003cstrong\u003eABB 3BSE007137R1 PFVO131\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3BSE007137R1 PFVO131\u003c\/strong\u003e Panel Unit, operates as a dedicated hardware component for structural mounting and signal routing within ABB AC110\/160 automation platforms. Configured for vertical mounting, this unit accommodates up to 8 S800 I\/O modules, enabling direct physical interfacing and field wiring management across distributed control system architectures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent Identifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Classification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003ctd\u003eSystem Manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e3BSE007137R1 PFVO131\u003c\/td\u003e\n\u003ctd\u003ePanel Unit Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003ePFVO131\u003c\/td\u003e\n\u003ctd\u003eSpare Module Reference Identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAC110\/160\u003c\/td\u003e\n\u003ctd\u003eIndustrial Controller Architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003ctd\u003eInternational Harmonized System Code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3BSE007137R1 PFVO131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.5 cm x 11.0 cm x 12.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e4.5 cm x 11.0 cm x 12.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C (-13 to +158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C (-40 to +185 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Slots\u003c\/td\u003e\n\u003ctd\u003e8 slots for S800 I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Orientation\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Entry\u003c\/td\u003e\n\u003ctd\u003eBottom and top gland openings (M20\/M25 knockouts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Backplane Bus Velocity and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe 3BSE007137R1 PFVO131 panel unit maintains high structural and backplane alignment for up to 8 S800 I\/O modules. By optimizing physical module spacing and backplane bus coupling, the unit prevents signal attenuation and communication latency across high-density I\/O configurations. Integrated top and bottom M20\/M25 knockout entries allow deterministic field cable management while isolating high-speed backplane signals from potential external electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x ABB 3BSE007137R1 PFVO131 Panel Unit\u003c\/li\u003e\n\u003cli\u003e1x Installation Instruction Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Configuration:\u003c\/strong\u003e Mount the panel unit in a vertical orientation on a flat control panel backplate using M4 or M5 mounting hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Gland Entry:\u003c\/strong\u003e Utilize the top or bottom gland openings equipped with M20 or M25 cable glands to route field input\/output wiring into the unit enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Route field I\/O cables separately from high-voltage AC lines to prevent cross-talk and preserve backplane signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding:\u003c\/strong\u003e Terminate field wiring shields to the panel frame ground (FG) bar using 360-deg braid shield clamps. Maintain ground path resistance under 100 ohms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow many module slots are provided by the 3BSE007137R1 PFVO131 panel unit?\u003c\/p\u003e\n\u003cp\u003eThe unit contains exactly 8 module slots dedicated to housing and interconnecting S800 I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat orientation is required for installing the PFVO131 panel unit?\u003c\/p\u003e\n\u003cp\u003eThe 3BSE007137R1 PFVO131 panel unit is specifically designed for vertical mounting inside control enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cable gland entry sizes are supported on the panel unit housing?\u003c\/p\u003e\n\u003cp\u003eThe housing features integrated knockouts designed for standard M20 and M25 cable glands at both top and bottom entry positions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the operating temperature range for the 3BSE007137R1 PFVO131?\u003c\/p\u003e\n\u003cp\u003eThe unit is rated for field operation across an ambient temperature range of -25 deg C to +70 deg C (-13 deg F to +158 deg F).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the 3BSE007137R1 PFVO131 consume backplane power?\u003c\/p\u003e\n\u003cp\u003eNo, the PFVO131 is a passive panel mounting assembly and draws zero backplane power (0 W).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping supported for I\/O modules seated in this panel unit?\u003c\/p\u003e\n\u003cp\u003eHot-swapping capability depends on the specific S800 I\/O modules and terminal bases installed within the 8 unit slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat shielding procedure should be followed for field wiring?\u003c\/p\u003e\n\u003cp\u003eField wiring shields must be terminated to the enclosure grounding bar with a 360-deg braid clamp, keeping earth resistance under 100 ohms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary function of the spare model designation PFVO131?\u003c\/p\u003e\n\u003cp\u003eThe PFVO131 identifier serves as the direct cross-reference and spare part catalog number for the 3BSE007137R1 panel unit assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021072289965,"sku":"3BSE007137R1 PFVO131","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_3bse007137r1_pfvo131_1.jpg?v=1787399581","url":"https:\/\/www.maxwellplc.com\/ga\/products\/abb-3bse007137r1-pfvo131-panel-unit-ac110-160-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}