{"product_id":"abb-1mrb150082r0103-500cu-bio01-expansion-module-reb500-series","title":"ABB 1MRB150082R0103 500CU-BIO01 Expansion Module REB500 Series","description":"\u003cp\u003eThe \u003cstrong\u003eABB 1MRB150082R0103 500CU-BIO01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e500CU-BIO01\u003c\/strong\u003e Expansion Module, operates as a dedicated hardware component for discrete status acquisition and control contact switching within \u003cstrong\u003eREB500\u003c\/strong\u003e busbar protection systems.\u003c\/p\u003e\n\u003ch3\u003eOrdering Reference \u0026amp; Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1MRB150082R0103\u003c\/strong\u003e: Primary ABB part number identification for order processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500CU-BIO01\u003c\/strong\u003e: Hardware model designation specifying the binary input\/output channel configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREB500 Series\u003c\/strong\u003e: Centralized and distributed busbar protection architecture platform.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Technical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1MRB150082R0103 500CU-BIO01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExpansion Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eREB500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24-250 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e2-10 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e2.5 kV RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e5 A @ 250 VAC \/ 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e16 x 23.3 x 2.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard backplane circuit draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHigh-Speed Backplane Integration \u0026amp; Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with the central unit backplane, maintaining backplane bus communication velocity across internal processing channels. Integrated circuit logic manages continuous I\/O density scaling throughout the subrack, while internal memory algorithms perform firmware flash compatibility validation on system power-up.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB 1MRB150082R0103 500CU-BIO01 Expansion Module\u003c\/li\u003e\n\u003cli\u003e1 x Anti-static ESD protective shield bag\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Mounting \u0026amp; Field Wiring Protocols\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRack Installation Procedure\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAlign the card edges with the subrack guide rails in the REB500 chassis bay.\u003c\/li\u003e\n\u003cli\u003ePush the module firmly until the rear connector seats completely into the backplane socket.\u003c\/li\u003e\n\u003cli\u003eFasten the panel retaining screws to a torque spec of 0.6 Nm to ensure grounded contact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eField Terminal Connections\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTerminate binary input and output field wires using stranded copper conductors up to 2.5 mm2.\u003c\/li\u003e\n\u003cli\u003eConnect all cable shields to the local earth grounding bar at the panel entrance.\u003c\/li\u003e\n\u003cli\u003eKeep low-voltage DC binary lines separated from high-power AC lines by a minimum of 200 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat input voltage range is supported by the binary inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 16 binary input channels accept continuous DC control voltages ranging from 24 VDC up to 250 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat current does each binary input channel draw during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach binary input channel draws an operating current between 2 mA and 10 mA across the input voltage range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs hot-swapping permitted for this expansion card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Main power to the REB500 subrack must be isolated prior to removing or inserting the expansion module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat electrical isolation rating applies between input channels and logic?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe board features galvanic isolation rated at 2.5 kV RMS between field input circuits and internal logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the maximum voltage and current limits for output contacts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 8 binary relay output contacts support continuous loads up to 5 A at 250 VAC or 30 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the board establish frame ground with the subrack chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFrame ground continuity relies on direct contact via front panel mounting screws and backplane ground contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat environmental humidity limits apply during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe card operates reliably in ambient humidity conditions ranging from 5% to 95% RH, non-condensing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow are firmware code mismatches handled upon system startup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAutomated firmware flash compatibility checks prevent initialized operation if card software diverges from host CPU code.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021080875181,"sku":"1MRB150082R0103 500CU-BIO01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_1mrb150004r0001500scm01_8_5e9d9d23-b68a-4fd4-8147-7e931863f4e0.jpg?v=1787892001","url":"https:\/\/www.maxwellplc.com\/ga\/products\/abb-1mrb150082r0103-500cu-bio01-expansion-module-reb500-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}