{"product_id":"990-05-xx-03-01-mod-168251-01-bently-nevada-990-series-vibration-transmitter","title":"990-05-XX-03-01 MOD:168251-01 Bently Nevada 990 Series Vibration Transmitter","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 990-05-XX-03-01 MOD:168251-01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e990\u003c\/strong\u003e Vibration Transmitter, operates as a dedicated hardware component for converting proximity vibration signals into monitoring outputs within Bently Nevada machinery protection systems.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Identification\u003c\/h3\u003e\n\u003cp\u003eThe 990-05-XX-03-01 MOD:168251-01 configuration contains selectable system length options and mechanical mounting features.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration Code\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eFull-scale vibration range: 0-5 mils pp (0-125 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXX\u003c\/td\u003e\n\u003ctd\u003eSystem length option: 5.0 meters (16.4 feet) or 7.0 meters (23.0 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eMounting option: DIN clips and screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eAgency approval: CSA Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e990-05-XX-03-01 MOD:168251-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e990 Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e990 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.44 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.4 x 4.6 x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0-5 mils pp (0-125 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length Option\u003c\/td\u003e\n\u003ctd\u003e5.0 meters (16.4 feet) \/ 7.0 meters (23.0 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Configuration\u003c\/td\u003e\n\u003ctd\u003eDIN clips and screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eCSA Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Signal Processing Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 990 Series transmitter processes proximity probe displacement signals and converts the measured vibration information into a proportional monitoring output.\u003c\/p\u003e\n\u003cp\u003eThe transmitter operation depends on correct eddy-current probe scaling, where shaft displacement variation is converted into an electrical measurement signal. During installation, gap voltage validation is required to confirm correct probe operating position and measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eThe unit is designed for machinery vibration monitoring circuits requiring consistent displacement signal conversion. Proper cable routing, grounding, and shielding practices reduce electrical interference and maintain signal quality.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 990-05-XX-03-01 MOD:168251-01 Vibration Transmitter\u003c\/li\u003e\n\u003cli\u003e1 x 0-5 mils pp measurement range configuration\u003c\/li\u003e\n\u003cli\u003e1 x DIN clip and screw mounting hardware configuration\u003c\/li\u003e\n\u003cli\u003e1 x CSA Division 2 approval configuration\u003c\/li\u003e\n\u003cli\u003eSystem cable length selection includes 5.0 meter or 7.0 meter option\u003c\/li\u003e\n\u003cli\u003eAdditional proximity probes, extension cables, manuals, and calibration accessories are not included unless specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the transmitter using the supplied DIN clips and screws mounting arrangement.\u003c\/li\u003e\n\u003cli\u003eVerify mechanical fixation before connecting field wiring.\u003c\/li\u003e\n\u003cli\u003eAvoid locations exposed to excessive mechanical shock or external vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFollow standard industrial signal wiring practices for proximity monitoring circuits.\u003c\/li\u003e\n\u003cli\u003eMaintain cable shielding continuity through the complete measurement path.\u003c\/li\u003e\n\u003cli\u003eSeparate signal wiring from high-voltage power cables to reduce electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommissioning Checks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify proximity probe gap voltage before operation.\u003c\/li\u003e\n\u003cli\u003eConfirm measurement range configuration matches the monitoring application.\u003c\/li\u003e\n\u003cli\u003eCheck output signal behavior during initial machinery rotation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat vibration range is configured for this transmitter?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 990-05-XX-03-01 MOD:168251-01 is configured with a 0-5 mils pp (0-125 um pp) full-scale measurement option.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat mounting hardware does this model use?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis configuration uses DIN clips and screws for mechanical installation within the monitoring system enclosure.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat system cable lengths are supported?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe configuration supports selectable system lengths of 5.0 meters (16.4 feet) and 7.0 meters (23.0 feet).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat type of sensor signal does the 990 transmitter process?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe transmitter processes proximity probe displacement signals used for vibration measurement applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIs CSA Division 2 approval included in this configuration?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYes. The 990-05-XX-03-01 MOD:168251-01 includes the CSA Division 2 agency approval option.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhy is probe gap voltage verification required?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGap voltage verification confirms the eddy-current probe operates within the correct measurement range before machinery monitoring.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDoes this transmitter require special cable routing?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSignal cables should be routed away from high-voltage conductors and protected from sources of electrical interference.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCan the measurement range be changed after installation?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe measurement range is defined by the selected factory configuration and should match the intended monitoring application.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026506567853,"sku":"990-05-XX-03-01 MOD:168251-01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/990-10-xx-01-05_144b7649-a1b8-4fca-96a4-4a1a87e835f5.jpg?v=1785737112","url":"https:\/\/www.maxwellplc.com\/ga\/products\/990-05-xx-03-01-mod-168251-01-bently-nevada-990-series-vibration-transmitter","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}